Table of Contents

Advertisement

Quick Links

Linoscan 2650 - Operation
Linoscan 2650
Operation
Edition April 2000
Order No. 05514045
ABC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Linoscan 2650 and is the answer not in the manual?

Questions and answers

Summary of Contents for HEIDELBERG Linoscan 2650

  • Page 1 Linoscan 2650 - Operation Linoscan 2650 Operation Edition April 2000 Order No. 05514045...
  • Page 2 Linoscan 2650 Operation...
  • Page 3 If any problems occur with the hout notice. product described in this manual, Heidelberger Druckmaschinen AG please contact Heidelberg. assumes no responsibility for European countries (except GB): information and description as far +49(241) 70 52 50 as third-party products are con- cerned.
  • Page 4: Table Of Contents

    Important Information ......VI HEIDELBERG online ......VII Intended Use .
  • Page 5 Table of Contents Start-up Notes on the Installation Location ... . . 2–1 Transport Safeguards ..... . . 2–2 Unlocking the Transport Safeguards .
  • Page 6 Conformity ........6–4 CE-Declaration of Conformity ....6–5 Index Linoscan 2650 – Operation...
  • Page 7: Before You Start

    Before you start ... Before you start ... About this Documentation This documentation applies to the Linoscan 2650 scanner. Note: The documentation must be kept available for use until the unit is recycled. Prerequisites You should be familiar with the basic functions of the WindowsNT/Apple ®...
  • Page 8: Important Information

    Before you start ... chapters, and sections. In PDF documentation, these cross-references are blue and underli- ned. Example: Refer to Chapter 4, Getting Started. S Getting Started PDF: Italics are also used to indicate menus, names of functions, hardware conditions, switch set- tings, and system messages.
  • Page 9: Heidelberg Online

    Before you start ... HEIDELBERG online Do you have questions concerning our products? Do you want to improve your workflows? Pay us a visit at our Internet home page. You will find us at: http://www.heidelberg.com/ Linoscan 2650 – Operation...
  • Page 10: Intended Use

    Before you start ... Intended Use The scanner is a flat bed scanner which is only to be used – in accordance with the manual – to scan photographic material and reflection originals. Do not use the device as a surface for the storage of objects and liquids.
  • Page 11: Interference To Monitors By Magnetic Fields

    Place the monitor at a different location Shield the source (e.g. shield the cable duct) Change the routing of the power supply cable Shield the monitor by means of a metal cover Linoscan 2650 – Operation...
  • Page 12: Radio Interference Suppression

    Before you start ... Radio Interference Suppression Note for European users To comply with directive 89/336/EEC it is neces- sary to operate the equipment with all covers cor- rectly installed. Ensure compliance with the radio interference suppression regulations, when you connect other electrical equipment to this unit following the rel- evant manufacturer’s instructions regarding cor- rect installation and maintenance.
  • Page 13: Cleaning (External)

    The surfaces of the device can be cleaned with a dry cloth. Remove any heavy soiling with a cloth which has been immersed in washing-up liquid and thor- oughly wrung out. Switch off the scanner before cleaning. Linoscan 2650 – Operation...
  • Page 14: Pollutants

    Maintenance As a rule, maintenance work may only be carried out by service personnel who have been autho- rized by Heidelberg. The relevant accident pre- vention regulations are to be adhered to at the same time. Edition April 2000...
  • Page 15: Introduction

    Fill out the Scanner registration card and send it to the address given. Note: If temperature variations are to be expected, ensure that the scanner is stored in the plastic packaging in its future location for 24 hours. Linoscan 2650 – Operation 1–1...
  • Page 16: General

    Introduction General The scanner scans originals of the following types (preferably of a rectangular shape): Reflective originals with the total size of the A3 Format (normal originals: maximum scanning area: 305 mm x 432 mm) Transparent originals in A3 format (film, etc.: maximum scanning area: 305 mm x 400 mm).
  • Page 17: Scanner Design

    Holds the original in position on the scanner dur- ing the scanning process. (2) Original Holder The original holder holds the original in position on the glass plate. Linoscan 2650 – Operation 1–3...
  • Page 18 Introduction (3) Original Glass Plate Put the original(s) to be scanned on the glass plate. Along the edges of the glass plate, you will find various measuring scales - inch, cm - and several formats - DIN formats: A3, A4, A5, A6, and B4. Special formats are DL (Double Letter = 11 inch x 17 inch), LT (Letter = 8.5 inch x 11 inch)
  • Page 19: Rearview

    (6) Switch for SCSI address Serves to set the scanner address. (7) Equipment Plug One end of the power cable plugs into the equip- ment socket, the other end plugs into the alternat- ing current socket. Linoscan 2650 – Operation 1–5...
  • Page 20: Ports

    Introduction (8) Ports The interface cables are plugged into the ports. The scanner is then connected to the Power Macintosh. (See page 2–11) (9) Terminator switch for SCSI chain Set this switch to terminate the SCSI chain. (10) FireWire Ports The FireWire cable is plugged into the FireWire Port.
  • Page 21: Handling Precautions

    Never touch the metal parts of the electronic components, such as the golden pins inserted in the slots. It is advisable to hold the system components either by the corners or on the mounting brackets. Linoscan 2650 – Operation 1–7...
  • Page 22: Start-Up

    Keep moisture, dust, and liquids away from the scanner. To ensure sufficient ventilation install the scanner such that there is enough space between the scan- ner and any walls or other objects. The minimum distance to a wall is 30 cm. Linoscan 2650 – Operation 2–1...
  • Page 23: Transport Safeguards

    Start-up Transport Safeguards Unlocking the Transport Safeguards The light transmission unit of the scanner is held by clamps. These protect the scanner against damages during transport. Before you start oper- ation of the scanner, the transport safeguards have to be unlocked. If the scanner is to be trans- ported again, the transport safeguards must be locked again.
  • Page 24 Start-up 3. Open the light transmission unit. Using your hand, push the clamps to both sides of the original holder from the locked position (inward) to the unlocked position (outward). Unlocked position Unlocked position Linoscan 2650 – Operation 2–3...
  • Page 25: Locking The Transport Safeguards

    Start-up Locking the Transport Safeguards The scanner must not be transported without pre- vious locking of the transport safeguards. 1. Switch the scanner off and back on again. After initialization, the scanner unit will automat- ically move into the correct position to fasten the transport safeguards.
  • Page 26: Connecting The Cables

    Power Cable Connection Observe the following instructions before you con- nect the power cable. The scanner can only be de-energized by the on/ off switch. Power receptacles such as sockets Linoscan 2650 – Operation 2–5...
  • Page 27 National regulations are to be observed when connecting using power cables which are not provided by Heidelberg, or when using plug adapters. Power cables used in the USA and Canada must at least be of type SJT.
  • Page 28 Never look into the fluorescent tubes when scan- ning with the transparent cover open. Should liquids enter the interior of the scanner, switch the scanner off immediately and remove the power cable from the socket. Linoscan 2650 – Operation 2–7...
  • Page 29: Notes On Power Cable

    Start-up Notes on Power Cable: Choose a cable from the table below and make sure to comply with the relevant national regula- tions to connect your scanner to AC mains volt- ages between 100 V and 127 V or 200 V and 240 V resp.
  • Page 30 If you do not use an adapter: 1. Plug the power cable into the equipment plug on the back of the scanner. 2. Plug the power plug into a wall socket. Linoscan 2650 – Operation 2–9...
  • Page 31 Start-up If you use an adapter: Warning: Before you plug in the adapter, connect the adapter ground cable with the grounding ter- S page minal. (See 2–5) Plug the power cable into the equipment socket on the back of the scanner. Don’t pull the cable but the plug when plugging or unplugging the power cable.
  • Page 32: Connecting The Interface Cable

    4. First switch on the scanner and then the scanner workstation. We recommend that you connect only one scanner to your scanner workstation and that you config- ure it as one of the terminating devices of the SCSI bus. Linoscan 2650 – Operation 2–11...
  • Page 33: Connecting The Firewire Cable

    Start-up Connecting the FireWire Cable Minimum hardware requirements: Mac OS 9.0 G3 blue&white, G4 1. Connect one end of the FireWire cable to the out- put on your scanner workstation. 2. Connect the other end of the FireWire cable to the connector on the scanner.
  • Page 34 Start-up FireWire Port Ports Linoscan 2650 – Operation 2–13...
  • Page 35: Setting The Scsi Id Address

    Start-up Setting the SCSI ID Address 1. Make sure that the SCSI address you wish to set your scanner to is not being used by another SCSI device connected to your scanner workstation. Note: The SCSI address you choose must be unique, i.e.
  • Page 36: Checking Termination

    SCSI bus. If further SCSI devices are connected “behind’’ the scanner, termination must not be activated – (OFF). <----- RULE: Only the first and the last device terminate the SCSI bus! Linoscan 2650 – Operation 2–15...
  • Page 37: Operation

    Operation 3 Operation Switching the Scanner On and Off Switching on the Scanner The scanner’s On/Off switch is located on the back of the device. On/Off switch Pilot lamp Linoscan 2650 – Operation 3–1...
  • Page 38: Switching Off The Scanner

    Operation 1. Set the On/Off switch to On. 2. Switch on the other SCSI equipment. 3. Switch on the scanner workstation to which the scanner is connected. 4. The pilot lamp starts flashing to indicate that the scanner is warming up. 5.
  • Page 39: Mounting Originals

    Do not touch the glass surface or the original holder with your bare hands. This prevents fin- ger marks or spots on the glass. Note: The calibration area must be kept clean to ensure a high degree of image quality. Linoscan 2650 – Operation 3–3...
  • Page 40: Scanning Originals

    Operation Scanning Originals Note: Prior to scanning, make two piles of origi- nals - transparent and reflective - to avoid having to force checking the lamps’ operating tempera- ture every time you change the scanning mode. It takes approx. 2 minutes until the lamp has reached its operating temperature.
  • Page 41 400 mm (transparent) Glass plate 432 mm (reflective) Cross-hatched area: Area in which scanning is not possible! 6. Open the light transmission unit and remove the original from the glass plate when the scan is complete. Linoscan 2650 – Operation 3–5...
  • Page 42: Using Passepartouts

    Operation Using Passepartouts 1. Insert the original to be scanned into a passepa- rtout (film holder) with the page to be scanned facing down. Note: Place the original symmetrically inside the passepartout. The area of the original located underneath the passepartout margin cannot be scanned.
  • Page 43: Notes On The Scanning Process

    Operation Notes on the Scanning Process Warning: Do not open the light transmission unit during the scanning process. Do not apply any pressure on the light transmis- sion unit. Linoscan 2650 – Operation 3–7...
  • Page 44: Cleaning

    Do not use organic solvents such as thinning agents or other such solutions. Make sure that no fluids get into the inside of the equipment. Cleaning the Original Glass Plate Original holder Original glass plate Linoscan 2650 – Operation 4–1...
  • Page 45: Cleaning The Original Holder

    If the plate attracts dust, soak the cloth with an anti-static medium or methanol with an antistatic medium. If the plate is scratched, it must be replaced. Con- tact the Heidelberg Hotline in such a case. 4–2 Edition April 2000...
  • Page 46: Cleaning The Outside Surface

    Do not use any abrasive cleaning agents or solvents. Wipe the original glass plate with a dry cloth or a cloth slightly moistened with a neutral detergent, alcohol or spirit. Linoscan 2650 – Operation 4–3...
  • Page 47: Troubleshooting

    LED dis- play lights continuously Replace the fluorescent Has the light source lamp become weaker? The light intensity can decrease after 3,000 operating hours and, thus, adversely affect the image quality. Linoscan 2650 – Operation 5–1...
  • Page 48 Troubleshooting Problem Possible Cause Corrective Action The scanned image is dis- The original was moved Close the original holder torted. during scanning. during scanning. Is the original placed cor- Place the original on the rectly on the glass plate? glass plate, so that it is flat.
  • Page 49: Technical Data

    Number of steps 16384 steps Data output Monochrome: line and gray levels RGB colors: gray levels Interface SCSI 2 (synchronous or asynchronous transmis- sion) FireWire IEEE 1394 Driver/software Linocolor installed in Power Macintosh Newcolor installed in PC Linoscan 2650 – Operation 6–1...
  • Page 50: External Dimensions

    Technical Data External Dimensions Height 216 mm (8.5") Length 908 mm (35.7") Width 564 mm (22.2") Weight 30 kg Noise level Below 55 dB(A) Ambient operating Operation: 5 -35 °C; guaranteed image quality temperature at: 18 – 27 °C Ambient humidity 20 - 80 % (noncondensing during operation) Connection Values Phases...
  • Page 51: Norms And Standards

    FCC, Part 15, Subpart B, Class A (USA) ICES - 003, Class A (Canada) VCCI, Class A (Japan) AS/NZS 3548, Class B (Australia/New Zealand) CNS 13438, Class B (Taiwan) Interference Immunity EN 55024 (Europe) IEC 1000-4-2/3/4/5/6/11 (international) Linoscan 2650 – Operation 6–3...
  • Page 52: Approvals

    Addresses can be obtained from the rele- vant environmental office or from the environ- mental representative at Heidelberg Prepress in Kiel. 6–4 Edition April 2000...
  • Page 53: Ce-Declaration Of Conformity

    Technical Data CE-Declaration of Conformity Linoscan 2650 – Operation 6–5...
  • Page 54 Technical Data 6–6 Edition April 2000...
  • Page 55 Mounting originals, 3–3 Notes on power cable, 2–8 Original glass plate, 1–4 Passepartout, 3–6 Pilot lamp, 1–4 Pollutants, XII Ports, 1–6 Power cable connection, 2–5 Rear view of scanner, 1–5 Safety Instructions, VIII Safety regulations, VIII Linoscan 2650 – Operation...