  • Page 1 Catalog No. HV052 EtherNet/IP- Compliant I/O Terminal YS8 User’s Manual er.1.0...
  • Page 2 ODVA, CIP, CompoNet, ControlNet, DeviceNet, and EtherNet/IP are trademarks of ODVA. The company and product names mentioned in this document are the trademarks or regis- tered trademarks of their respective companies.
  • Page 3: Table Of Contents

    HV052 1. Table of Contents I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 1. Table of Contents 1. Table of Contents ............................1 2. Revision History ............................4 3. Safety Precautions (I/O Terminal) ......................5 4. Glossary ................................8 5. Overview ...............................10 6.
  • Page 4 HV052 1. Table of Contents I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 9-2. How to Increase/Decrease Number of I/O Expansion Modules ..........32 10. Installation ..............................36 10-1. Installation via Direct Mounting ......................36 10-2. Installation to DIN rail........................36 11. Wiring Precautions ...........................37 12.
  • Page 5 HV052 1. Table of Contents I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-6. LLDP Management (Class Code: 109 Hex) .................56 15-6-1. Service Code ..........................56 15-6-2. Attribute ............................56 15-7. Statistical Data (Class Code: A0 Hex) ..................57 15-7-1. Service Code ..........................57 15-7-2.
  • Page 6: Revision History

    HV052 2. Revision History I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 2. Revision History Date of revision Description of revision 12/2/2022 First printing...
  • Page 7: Safety Precautions (I/O Terminal)

    With regard to the handling of and precautions for solenoid valves, be sure to read the Safety Precautions TION and Handling Instructions and General Precautions in the catalog on the Koganei website before use. 3. Safety Precautions (I/O Terminal) Please read these Safety Precautions carefully before selecting a model and using the product in question, and make sure to use it properly.
  • Page 8 HV052 3. Safety Precautions (I/O Terminal) I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 During Operation Fail-safe • Do not touch or place your hand or body near the product while • Output may remain on or off due to welding or burnout of the it is in operation.
  • Page 9 HV052 3. Safety Precautions (I/O Terminal) I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Installation • For hazards, warnings, and precautions not listed in this Safe- ty Precautions section, refer to Safety Precautions (shared • To protect the module, be sure to attach the module connec- between air valves and other control equipment and between tion cover at the end of the module.
  • Page 10: Glossary

    HV052 4. Glossary I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 4. Glossary Terminology Description Scanner With EtherNet/IP, the master in the master/slave system is called a scanner. Adapter With EtherNet/IP, the slave in the master/slave system is called an adapter.
  • Page 11 HV052 4. Glossary I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Terminology Description Full duplex communication Communications are sent and received simultaneously. Half duplex communication Communications in which receiving cannot be done while sending, and sending cannot be done while receiving.
  • Page 12: Overview

    HV052 5. Overview I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 5. Overview I/O terminals are devices that can be connected to various open field networks to reduce the amount of wiring and enable distributed installation of input/output devices. Up to 20 F10 and F15 series manifold solenoid valves (32 control points) and up to 8 I/O expansion modules can be connected.
  • Page 13: Communication Module

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-2. Communication Module This section describes the specifications, names, and functions for the EtherNet/IP-Compliant communication module YS8-M3. 6-2-1. Specifications Model YS8-M3 Internal current consumption 100mA or less (excluding I/O modules and solenoid...
  • Page 14: Major Parts And Functions

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-2-2. Major Parts and Functions YS8-M3 (Front) LED displays and descriptions Name Details □ Not lit No power supply for the LEDs unit Address setting ■ Lit green Power being supplied to...
  • Page 15: Hardware Switch

    *1 Factory setting Reset Switch YS8-M3 settings can be restored to the factory default settings by pressing and holding the reset switch for more than four seconds while power is supplied to the control and input power supplies. Refer to the list of factory default settings for the factory default settings.
  • Page 16: Connectable I/O Expansion Modules

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-2-4. Connectable I/O Expansion Modules Four I/O expansion modules of the same type can be connected to the communication module, for a total of up to eight I/O expansion modules.
  • Page 17: Digital Input Module

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-3. Digital Input Module This section describes the names and specifications for the various parts of I/O expansion modules YS8-D8N/YS8-D8N-P/YS8-D16N. 6-3-1. Major Parts and Functions YS8-D8N/YS8-D8N-P YS8-D16N (Front) (Front) ①...
  • Page 18: Specifications

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-3-2. Specifications Model YS8-D16N YS8-D8N YS8-D8N-P Input specifications Number of input 16 points 8 points points Maximum sensor 1A/Module - supply current Rated input current 7.5mA or less (at 26.4V) *per point ON voltage/ON 15V or more/3.9mA or more...
  • Page 19 HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 YS8-D8N internal circuit YS8-D8N-P internal circuit Communication Communication Digital input module Digital input module module module Overcurrent Overcurrent detection detection For input module For input module Internal Internal Power supply (UNIT)
  • Page 20: Analog Input Module

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-4. Analog Input Module This section describes the names and specifications for the various parts of the YS8-A4N I/O expansion module. 6-4-1. Major Parts and Functions YS8-A4N (Front) (Bottom) ①...
  • Page 21: Specifications

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-4-2. Specifications Model YS8-A4N Input specifications Voltage Current Number of input points Four points Maximum sensor supply 1A/Module current Rated input voltage/current 40mA Input impedance 1MΩ 250Ω Input signal range 0-5V/0-10V 0–20 mA...
  • Page 22: A/D Conversion Table

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 YS8-A4N circuit diagram Communication Analog input module module Overcurrent detection Voltage-current For input module conversion conversion circuit circuit Power supply (UNIT) DC24V 6-4-4. A/D conversion table Input range 0-5V...
  • Page 23 HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Input range 0-10V A/D con- Input voltage version value 1200 1600 2000 2400 Input voltage (V) 2800 3200 3600 4000 *The A/D conversion value is 4095 for inputs above 10.24V.
  • Page 24: Digital Output Module

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-5. Digital Output Module This section describes the part names and specifications for the YS8-D8S/YS8-D8S-M I/O expansion modules. 6-5-1. Major Parts and Functions YS8-D8S/YS8-D8S- (Front) ① Status LED ② OUT LED ③...
  • Page 25: Specifications

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-5-2. Specifications Model YS8-D8S YS8-D8S-M Output Specifications Sink Source Number of output 8 points points Maximum load current 0.5A/channel, 1A/module Protective function Overcurrent detection, output short-circuit protection Internal current...
  • Page 26 HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 YS8-D8S-M pin assignments Shape Channel Pin No. Signal name Channel Pin No. Signal name N.C.1 N.C.2 DOUT1 DOUT2 GND1 GND2 N.C.3 N.C.4 DOUT3 DOUT4 GND3 GND4 N.C.5 N.C.7 DOUT5...
  • Page 27: Analog Output Module

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-6. Analog Output Module This section describes the names and specifications of the various parts of the YS8-A2S I/O expansion module. 6-6-1. Major Parts and Functions YS8-A2S (Front) (Bottom) ①...
  • Page 28: Specifications

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-6-2. Specifications Model YS8-A2S Output Specifications Voltage Current Number of output points Two points Maximum load current 1A/Module Load impedance 1kΩ or more 600Ω or less Output signal range 0-5V/0-10V 0–20 mA...
  • Page 29: D/A Conversion Table

    HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 6-6-4. D/A Conversion Table Output range 0-5V Output D/A conversion command value (V) value 1200 1600 2000 2400 2800 3200 Output command value (digit) 3600 4000 *Output is 5.12V for outputs specified at 4095 or above.
  • Page 30 HV052 6. Specifications I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Output range 0-20mA Output A/D conversion command value (mA) value 1200 1600 2000 2400 2800 3200 Output command value (digit) 3600 4000 *Output is 20.48mA for output commands of 4095 or above.
  • Page 31: Eds File

    HV052 7. EDS File I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 7. EDS File Download from https://official.en.koganei.co.jp/. 8. IP Address Settings Please select the setting method according to the address you wish to set. Address to be set Setting method 192.168.1.1 - 99...
  • Page 32: Setup Using Support Software

    HV052 8. IP Address Settings I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 8-2. Setup Using Support Software Setting the address setting switch to "00" allows you to set the address to any desired address. Make sure that the I/O terminal power is off.
  • Page 33: Increasing/Decreasing Number Of I/O Expansion Modules

    HV052 9. Increasing/Decreasing Number of I/O Expansion Modules I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 9. Increasing/Decreasing Number of I/O Expansion Modules 9-1. Precautions for Increasing/Decreasing Number of Modules ・ Be sure to turn off the power to the communication module before increasing or decreasing the number of I/O expansion modules.
  • Page 34: How To Increase/Decrease Number Of I/O Expansion Modules

    As an example of how to increase or decrease the number of modules, we will explain how to increase the number of I/O terminals by adding a digital input module (YS8-D8N) to an I/O terminal with the following initial configuration.
  • Page 35 HV052 9. Increasing/Decreasing Number of I/O Expansion Modules I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 ③ Disconnect the I/O expansion module from the communication module. ④ Remove the connecting rod from the communication module. * Keep the connecting rod together with the screws and washers shown in ② . It will be used when reverting to the original number of connections.
  • Page 36 HV052 9. Increasing/Decreasing Number of I/O Expansion Modules I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 ⑥ Insert the expansion I/O module along the connecting rod and connect it to the communication module. ⑦ Prepare the washers and screws included with the additional part YS8Z-5 and screw them into...
  • Page 37: Direct Mount

    HV052 9. Increasing/Decreasing Number of I/O Expansion Modules I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 ⑧ If an expansion I/O module is added to the end, install the mounting bracket removed in ① and screw it in the same way using the screws removed in ① . Refer to the table below for the instal- lation positions of the metal fittings.
  • Page 38: Installation

    HV052 10. Installation I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 10. Installation This section describes how to install I/O terminals. 10-1. Installation via Direct Mounting Obtain M4 screws and screw them perpendicularly to the mounting holes. [Tightening torque 1.47 N ・ m ± 15%] 10-2.
  • Page 39: Wiring Precautions

    ・ When wiring with stranded wires, twist the wires so that there are no whiskers. ・ Do not solder the wire ends. ・ When removing the connectors from the modules, loosen the connector screws (except with YS8- D16N) and pull the connector straight out of the module.
  • Page 40: I/O Data Allocation

    HV052 12. I/O Data Allocation I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 12. I/O Data Allocation Performs fixed-size, fixed-address I/O data allocation regardless of the type or serial number of the valves connected to the communication module or the type or connection location of the I/O expansion module.
  • Page 41: Relationship Between I/O Data Allocation And Solenoid Valves

    HV052 12. I/O Data Allocation I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 12-2. Relationship Between I/O Data Allocation and Solenoid Valves The relationship between the solenoid valves and the allocation of I/O data varies according to the "wiring specifications" specified in the order number of the manifold.
  • Page 42 HV052 12. I/O Data Allocation I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Output supported by example configuration Bits VALVE 1 VALVE 2 Blank (packed wiring) Stations Solenoids Stations Solenoids -W (double wiring) Stations Solenoids Stations Solenoids : Unused area...
  • Page 43: Input Data Allocation Details [I/O Terminal → Scanner]

    ・ While YS8-D8N and YS8-D8N-P have 8-channel specifications, note that the I/O area uses 2 bytes (16 channels). The latter byte is a reserved area and cannot be used. ・ The YS8-A4N channels store the AD conversion value in the first 12 bits of the allocated 2-byte I/O area. The high-order 4 bits cannot be used.
  • Page 44: Output Data Allocation Details [Scanner → I/O Terminal]

    The latter byte is a reserved area and cannot be used. ・ The YS8-A2S channels performs DA conversion of the value stored in the first 12 bits of the allocated 2-byte I/O area. The high-order 4 bits cannot be used.
  • Page 45: Parameter Settings

    I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 13. Parameter Settings YS8-M3 has parameters that can be set for each module/channel. The various parameters can be set using the support software provided by the PLC vendor or Explicit Message communication.
  • Page 46: Parameter Description

    HV052 13. Parameter Settings I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 13-2. Parameter Description 13-2-1. [ Valve / Digital Output Group / Analog Output Group ] Failure Reaction Intended Uses Maintains or clears the output state when a communication error is detected.
  • Page 47: Analog Input Filter Measured Value

    HV052 13. Parameter Settings I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 13-2-3. Analog Input Filter Measured Value Intended Uses When the input value fluctuates and is unstable due to noise and other factors, the input value is stabilized by taking a moving average.
  • Page 48: Network Topology

    HV052 14. Network Topology I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 14. Network Topology The YS8-M3 supports the following connection formats. ◦ Line format ◦ Star format ◦ Device level ring format 14-1. Line Format A line format network connects devices in a daisy chain format. Switching hubs are not needed, and the total length of the LAN cable can be reduced.
  • Page 49: Device Level Ring Format

    HV052 14. Network Topology I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 14-3. Device Level Ring Format A device level ring (hereafter DLR) format network is resilient to breakdowns. The connections are maintained by switching to line format communications if a line is cut or a device in the ring malfunctions. A control device known as a supervisor must be installed on the network.
  • Page 50: Cip Class Objects

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15. CIP Class Objects Name of object Class code Description Identity 01 hex Provides information that identifies a product. TCP/IP Interface F5 hex Provides the interface for the TCP/IP network.
  • Page 51: Identity (Class Code: 01 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-1. Identity (Class Code: 01 Hex) 15-1-1. Service Code Service code Name 01 hex Get_Attribute_All 05 hex Reset 0E hex Get_Attribute_Single 15-1-2. Attribute Instance Data Attribute Access...
  • Page 52 HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Factory Settings List Item Initial value Name of object Attribute How to Set IP Addresses 2 = DHCP TCP/IP Configuration Method Interface IP address 0.0.0.0 Configuration Control Subnet mask 0.0.0.0...
  • Page 53: Tcp/Ip Interface (Class Code: F5 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-2. TCP/IP Interface (Class Code: F5 Hex) 15-2-1. Service Code Service code Name 01 hex Get_Attribute_All 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 15-2-2. Attribute Instance Attribute Access...
  • Page 54 HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Instance Attribute Access Name Description Data format Mcast Config Multicast address settings Structure Method to allocate multicast ad- Alloc Control USINT dress Get/Set Reserved Reserved USINT Num Mcast...
  • Page 55: Ethernet Link (Class Code: F6 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-3 Ethernet Link (Class Code: F6 Hex) 15-3-1 Service Code Service code Name 01 hex Get_Attribute_All 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 15-3-2 Attribute Instance Attribute Access...
  • Page 56 HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Instance Attribute Access Name Description Data format Media Counters Ethernet media counter Structure Number of received frames Alignment Errors UDINT whose lengths were not octets Number of frames received that...
  • Page 57: Device Level Ring (Class Code: 47 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-4. Device Level Ring (Class Code: 47 Hex) 15-4-.1 Service Code Name Service code 0E hex Get_Attribute_Single 15-4-2. Attribute Instance Attribute Access Name Description Data format Revision of Device Level Ring...
  • Page 58: Quality Of Service (Class Code: 48 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-5. Quality of Service (Class Code: 48 Hex) 15-5-1. Service Code Service code Name 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 15-5-2. Attribute Instance Data Attribute Access Name...
  • Page 59: Statistical Data (Class Code: A0 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-7. Statistical Data (Class Code: A0 Hex) 15-7-1. Service Code Service code Name 0E hex Get_Attribute_Single 15-7-2. Attribute Instance Attribute Access Name Description Data format Time from power on to...
  • Page 60: Valve Point (Class Code: B1 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-8. Valve Point (Class Code: B1 Hex) 15-8-1. Service Code Service code Name 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 15-8-2. Attribute Instance Attribute Access Name Description Data format...
  • Page 61: Digital Input Point (Class Code: B2 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-9. Digital Input Point (Class Code: B2 Hex) 15-9-1. Service Code Service code Name 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 15-9. Attribute Instance Attribute Access Name Description...
  • Page 62: Valve Point Group (Class Code: B6 Hex)

    HV052 15. CIP Class Objects I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 15-11. Valve Point Group (Class Code: B6 Hex) 15-11-1. Service Code Service code Name 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 15-11-2. Attribute Instance Attribute Access Name Description...
  • Page 63: Web Page

    HV052 16. Web Page I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 16. Web Page You can check the internal status of the YS8-M3 EtherNet/IP-compatible communication module from the web page. 16-1 How to Use 1. Open a browser. 2. Input the I/O terminal IP address in the URL field.
  • Page 64: Handling Abnormalities

    HV052 17. Handling Abnormalities I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 17. Handling Abnormalities The internal status can be diagnosed using the LEDS on the communication module and the I/O expansion modules. 17-1. LED Positions L/A IN L/A OUT P –...
  • Page 65   You cannot connect more than eight I/O modules. Reset the power supply after addressing the above po- tential causes. * Note that the YS8-A2S does not detect an increase or decrease in the number of connections. There is no power supply for the module.
  • Page 66 HV052 17. Handling Abnormalities I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 ST - Status Status Causes/Solutions ■ Status is normal. green Overcurrent detected. ■ Confirm the I/O module wiring. Address the cause of the issue and reset the Lit red power supply.
  • Page 67: External Dimensions

    HV052 18. External Dimensions I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 18. External Dimensions Communication module YS8-M3 (Unit:mm) 2-Ø3.2Through 2-Ø4.6Depth 5 Ø6 Seat depth 17 (with M3 nut for connecting rod) Digital input module YS8-D8N / YS8-D8N-P YS8-D16N 2-04.6Through Ø...
  • Page 68 HV052 18. External Dimensions I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Analog input module YS8-A4N (Unit:mm) Ø 4.6Through (for connecting rod) Digital output module YS8-D8S/YS8-D8S-M Ø 2-04.6Through 4.6Through (for connecting rod) (for connecting rod)
  • Page 69 HV052 18. External Dimensions I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 Analog output module YS8-A2S (Unit:mm) Ø 4.6Through (for connecting rod)
  • Page 70: Appendix

    HV052 19. Appendix I/O Terminal YS8 EtherNet/IP-Compliant User’s Manual Ver. 1.0 19. Appendix 19-1. Software Licenses and Copyrights Third-party software is embedded in this product. See https://official.koganei.co.jp/common/html/3rd- party-license.html for information about licenses and copyrights for this software.
  • Page 71 *For other information, detailed specifications, and precautions, see the product catalog. *For inquiries about the product, contact your nearest Koganei sales office or the Overseas Department noted below. Overseas Department TEL:042-383-7172 ● The specifications or the appearance of this productare subject to change any time without prior notice.