Do you have a question about the KAPAC400 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for KickAss KAPAC400
Page 1
400W PORTABLE AIR CONDITIONER OWNER’S MANUAL KAPAC400 V1.1...
Page 2
TABLE OF CONTENTS -------------------------------------- WARNING AND SAFETY INFORMATION -------------------------------------------------- PRODUCT SPECIFICATIONS ---------------------------------------------------- COMPONENTS INCLUDED ----------------------- UNDERSTANDING YOUR KICKASS AIR CONDITIONER --------------------------------------------------------- PARTS DIAGRAM --------------------------------------------------------- TOUCH CONTROL ------------------------------------------------------- REMOTE CONTROL ---------------------------------------------------- ACCESSORY CONNECTION ------------------------------ DRAINPIPE CONNECTION INSTRUCTIONS ------------------- REAR EXHAUST DUCT CONNECTION INSTRUCTIONS...
Page 3
WARNING AND SAFETY INFORMATION • Ensure installation complies with local power grid wiring rules and proper grounding. • Consult a professional electrician if unsure about the electrical installation. • Place the unit on a flat, dry surface. • Maintain at least 50 cm of clearance between the unit and surrounding walls or objects.
Page 4
• The unit uses R290 refrigerant, which is environmentally friendly but highly flammable, and handle with care. • The remote control contains 1 x CR 2025 lithium coin cell battery. This is dangerous if swallowed. • Keep the coin cell battery out of reach of children. •...
Page 5
PRODUCT SPECIFICATIONS AC Input 220-240V, 50Hz, 427W Max AC Input current 1.87A Refrigerant / Amount R290 /80g Cooling area ≤ 6 sqm Cooling capacity 3100BTU/900W Product weight 13kg Product dimensions 356 x 298 x 356mm IP rating IPX1 Noise Level ≤50dB EESS Certification CCS-240526-EA...
Page 6
COMPONENTS INCLUDED DUAL EXHAUST DUCT MAIN AC UNIT REMOTE CONTROL STAND LEGS EXTERIOR EXHAUST DUCT DRAIN HOSE COUPLER CONNECTOR LARGE EXHAUST SMALL EXHAUST WINDOW SPACER KIT DUCT (130MM) DUCT (80MM)
Page 7
UNDERSTANDING YOUR KICKASS 400W PORTABLE AIR CONDITIONER PARTS DIAGRAM 1. Control panel 2. Carry handle 3. Air Outlet Louvers 4. Airflow Adjustment Lever 5. Air Intake Grille 6. Dust Filter 7. Hot Air Exhaust Port 8. Rear Air Intake Grille 9.
Page 8
TOUCH CONTROL 1. Lock: Short press the button to turn on or off the child lock feature. 2. Timer: Short press the button to set a timed shutdown when ON Mode; Short press the button to set a timed start up when OFF Mode. Quick press the button to set timing (1 –...
Page 9
REMOTE CONTROL Short press to turn the air conditioner ON or OFF. Short press to turn on or off the child lock feature. Short press to activate the sleeping mode. Short press to decrease the required temperature. Short press to set a timed shutdown when ON Mode; Short press the button to set a timed start up when OFF Mode.
Page 10
ACCESSORY CONNECTION DRAINPIPE CONNECTION INSTRUCTIONS The air conditioner offers two convenient options for water drainage: 1. Using the built in 1.5L internal water tank for water collection 2. Using the supplied drain hose for continuous drainage Option 1: Using the internal water tank •...
Page 11
Option 2: Using the supplied drain hose for continuous drainage • Locate the drainage outlet at the back of the machine. • Remove the blocket and securely attach the drain hose to the outlet. • Direct the hose to a suitable drainage location such as container or appropriate outdoor area when camping.
Page 12
• If you are using this portable air conditioner inside a room where you can use the window spacer kit to vent the exhaust outside: 1. Install the window spacer kits: Place the window spacer kit into an available window or opening that can be sealed.
Page 13
COLD EXHAUST DUCT CONNECTION INSTRUCTIONS • This accessory can be used in some environment where it is not possible to place the air conditioner for cold air to reach the position we want. • Attach and secure the two small exhaust ducts counterclockwise into the dual exhaust duct connector.
Page 14
WASHING AND MAINTENANCE INSTRUCTIONS 1. Surface Cleaning • Before cleaning or performing any maintenance, turn off the machine and unplug it. • Wipe the surface with a soft, damp cloth • Do not use harsh chemicals such as alcohol or gasoline as they may damage the surface or the entire unit.
Page 15
TROUBLESHOOTING TIPS PROBLEM REASON SOLUTION No power Ensure the machine is connected The air conditioner to an electrical socket and turn it does not work FL indicator (full water) Drain the water inside the unit. Room temperature is lower than Operate the unit in the set temperature (cooling) or recommended temperature...
Page 16
KickAss is a registered trademark of KickAss Products Pty Ltd Designed & imported by KickAss Products Pty Ltd 39 Iris Place, Acacia Ridge, QLD 4110 Australia Made in China...
Need help?
Do you have a question about the KAPAC400 and is the answer not in the manual?