Download Print this page

Advertisement

Quick Links

USER
MANUAL
MM6500 MULTIMETER
MM6500
EN ENGLISH
Manual in your
language?
Check the back cover

Advertisement

loading
Need help?

Need help?

Do you have a question about the MM6500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Futech MM6500

  • Page 1 USER EN ENGLISH MANUAL Manual in your language? MM6500 MULTIMETER Check the back cover MM6500...
  • Page 2 OVERVIEW B C D G H I Manual Auto Live NCV V.F.C MM6500 μ mμnF Mk Hz DEVICE 01 Non-contact voltage sensor 02 Non-contact voltage indicator light 03 LCD Display 04 Select button 05 HOLD button 06 Flashlight button 07 VFC button...
  • Page 3 DISPLAY SAFETY Automatic shutdown indicator Please read the safety instructions provided in the separate Hold reading indicator booklet provided with the device before using. Automatic range mode indicator · Do not exceed 1000V when making category III measure- Manual range mode indicator ments, or 600V when making category IV measurements.
  • Page 4 LIGHTING FUNCTION NOTE When not in use for a long time, please remove the battery The device has a built-in flashlight to allow for operations in and avoid storing it in a place with high temperature and darker lighting conditions. To turn on the flashlight: humidity. · Press the flashlight button [06] once to turn on the light · Press the flashlight button [06] once more to turn the flash- FIRST TIME USAGE light off again.
  • Page 5 AUTOMATIC RANGE · Rotate the rotary knob [08] to face the automatic range measurement mode · press the Select button [04] to switch between AC and DC measurement. · Use the other ends on the measurement probes to measure the voltage value of the circuit under test. ·...
  • Page 6 · Connect the black measurement probe to the COM input MEASURING RESISTANCE terminal [12] and the red probe to the Ω input terminal [11]. NOTE To avoid damage to the instrument or the device under test, turn off all power to the circuit under test and fully discharge all high-voltage capacitors before measuring resistance. AUTOMATIC RANGE ·...
  • Page 7 · Rotate the rotary knob [08] to face the measurement will turn on and the buzzer will make a continuous sound. mode. Between 15Ω~30Ω the indicator light (green) will flash and the buzzer will beep continuously. MEASURING CAPACITANCE NOTE To avoid damage to the instrument or the device under test, turn off all power to the circuit under test and fully discharge all high-voltage capacitors before measuring capacity.
  • Page 8 · Use the other ends of the measurement probes to measure · Connect the black measurement probe to the COM input the capacitance value of the object to be tested. The result will terminal [12] and the red probe to the V input terminal [11]. be shown on the display [03].
  • Page 9 · Rotate the rotary knob [08] to face the appropriate range in · Disconnect the circuit to be tested. the AC ( A~) or DC (A )measurement mode. · Connect the black measurement probe to the terminal of the disconected circuit with the lower voltage. · Connect the red measurement probe to the terminal with the higher voltage.
  • Page 10 · Sensing high voltage, two indictators [02] will light up red and If the instrument detects AC voltage, it will judge wether the the display [03] will show “-- H“. The buzzer willl also sound voltage is a firewire according to the detected strength. If it is an alarm. judged to be a live line; the display [03] will read “LIVE” and the green indicator light [02] will be on.
  • Page 11 PRECISION INDEX TECHNICAL SPECIFICATIONS DC VOLTAGE CONDITIONS FOR USAGE RANGE RESOLUTION ACCURACY MODEL MM6500 999.9mV 0.1mV Protection 600V CAT. IV and 1000V CAT. lll 9.999V ± 0.5% reading + 3 digits Pollution degree Degree 2 99.99V 10mV Operational altitude < 2000 m 999.9V...
  • Page 12 FREQUENCY BUZZER AND CONTINUITY TEST RANGE RESOLUTION ACCURACY FUNCTION RANGE ACCURACY DESCRIPTION TEST CONDITION 9.999Hz 0.001Hz Built-in buzzer sounds and the green light 99.99Hz 0.01Hz [02] turns on when resistance < 15Ω. Open-circuit 999.9Hz 0.1Hz 100Ω 1Ω Between 15 and 30Ω voltage: ±1V 9.999KHz 0.001kHz ±...
  • Page 13 Frequency response: 40Hz-1kHz, true RMS DIRECT CURRENT TEMPERATURE RANGE RESOLUTION ACCURACY 99.99A 0.01A RANGE RESOLUTION ACCURACY 999.9mA 0.01mA ± 0.8% reading + 3 digits -20°C ~1000°C 1°C 600mA 0.1mA ± 1.0% reading + 3 digits -4°F ~1832°F 1°F 10.00A 10mA ± 1.2% reading + 3 digits Overload protection: 600V AC/DC Max input mA input: 600mA DC or AC RMS Max input 10A input: 10A DC or AC RMS...
  • Page 14 DECLARATION OF CONFORMITY Futech (Belgium) declares under its own responsibility that this device: - MM6500 Multimeter is in conformity with the standards - EN61326-1:2013 - EN61326-2-2:2013 - EN61000-3-2:2014 - EN61000-3-3:2013 - EN61010-1:2010 - EN61010-2-030:2010 - EN61010-2-033:2012 under directive EMC - 2014/30/EU...
  • Page 15 NOTES...
  • Page 16 USER MANUAL other languages: DANSK ITALIANO DEUTSCH NEDERLANDS ESPAÑOL NORSK EESTI KEEL PORTUGUÊS SUOMEN KIELI SLOVENŠČINA FRANÇAIS SVENSKA ÍSLENSKA Facebook @futechtools LinkedIn futechtools World Wide Web futech-easy.com YouTube @futechtools...