Summary of Contents for KYOWA DSMC-100A Series
Page 1
. Forbid copying it without permission, and reproducing some or all of this product. This product is a book of Kyowa Electronics Instruments Co., Ltd., and the copyright belongs to Kyowa Electronics Instruments Co., Ltd. Change the contents of the instruction manual may be without a notice.
Page 2
IM-A-1332 Contents 2020.12 1. Introduction ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 2 2. Preparations for Offline Analysis software ・・・・・・・・・・・・・・・・・・・・・・・ 3 ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3 2-1. Preparation ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 4 2-2. Start of the Offline Analysis software ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 5 2-3. End of the Offline Analysis software 3. Screen explanation ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 3-1. Main Screen 4. Operating instructions ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・...
Page 3
IM-A-1332 1. Introduction 2020.12 Thank you for purchasing sampling moire camera displacement measurement device offline analysis soft. In this manual, we'll explain about a procedure to install application. ●Please read this manual before use this product. ●This manual may be changed without a notice. ●Windows 7 and Windows 10 are registered trademarks of American Microsoft.
Page 4
IM-A-1332 2. Preparations for Offline Analysis software 2020.12 2-1. Preparation Connect the dongle key to the Universal Serial Bus port before start of the Offline analysis software (the following, offline). 1. Connect the dongle key to the Universal Serial Bus port. ! CAUTION Offline cannot start when you do not connect the dongle key.(P.4)...
Page 5
IM-A-1332 2020.12 2-2. Start of the OfflineAnalysis software Start off-line software. 1. Double-click “OfflineAnalysis” icon. “During start” screen is displayed when you start, “Main” screen is displayed afterwards . “During start” Screen “Main” Screen ! CAUTION When startting without connecting the dongle key, the left message will be displayed.
Page 6
IM-A-1332 2020.12 2-3. End of the Offline analysis software End off-line software. 1. Click “Close” button in the main screen. “Main” Screen...
Page 7
IM-A-1332 3. Screen explanation 2020.12 3-1. Main Screen About the main screen, show the list of operation below. ③ ⑪ ⑩ ⑱ ⑲ ① ② ④ ⑤ ⑧ ⑨ ⑥ ⑦ ⑫ ⑬ ⑭ ⑮ ⑰ ⑯ ⑱ ⑳ ⑲ “Main” Screen Name Content ①...
Page 8
IM-A-1332 4. Operating Instructions 2020.12 4-1. To analyze it? Explain off-line analytical procedure. 1. Please click “Analysis image choice” menu or “Folder” menu. “Browse For Folder” screen is displayed. Please click “OK” button after choice with the analysis folder . “Analysis image choice” Menu “Folder”...
Page 9
IM-A-1332 2020.12 3. Please click “Start” button. Analysis is started. “Runtime” Screen “Runtime” Screen “Runtime” Screen (Standard acquisition) (Image generation) (Phase analysis) 上図(1) 4: completion images number Processing automatically changes like an upper figure. 250: Object images number 上図(2) Remaining time 4.
Page 10
IM-A-1332 2020.12 4-2. To edit the analyzing area? Explain the position of the analysis area and an editing method of the size. Illustrate by the premise that the analysis image is chosen. 1. Select “1. Area” of “Area Edit” menu, please decide editing area No. . Supplement Explain the color of the area frame displayed in “Image Monitor”...
Page 11
IM-A-1332 2020.12 4. When change “5. Center X”, “6. Center Y” of “Area Edit” menu, can change position of area. In addition, when change “7. Width”, “8. Height”, can change size of area. Supplement Can change position and size of the area by mouse operation from “Image monitor” menu. ・Position :...
Page 12
IM-A-1332 2020.12 8. You can select to use or not, by “18.Z Correct” of “Area Edit” menu. Supplement Set whether the Z correction is valid or invalid. 9. Set “19.Z MA” of “Area Edit” menu. Supplement Set moving average of Z displacement. 10.
Page 13
IM-A-1332 2020.12 4-3. To confirm the analysis result? Explain various confirmation methods about the analysis result. 4-3-1.To confirm various processing images? 1. Please left double click “Area Monitor” menu. “Image Select” context menu is displayed. Please choose middle image what you want to confirm. Supplement The default is “Original image”...
Page 14
IM-A-1332 2020.12 4-3-4.To confirm the analysis result from graph? 1. Please right click “Displacement result” graph. “Graph Operation” context menu is displayed. Please choose processing that you want to confirm. Supplement Plot color and each axial content as follows. ・Plot Blue: Displacement average value (Unit : mm) ・Plot Green:...
Page 15
IM-A-1332 2020.12 4-3-5.To confirm the analysis result in detail? 1. Please double-click the area frame of “Image Monitor” menu. To “Cursor Mode”, you can confirm the displacement every pixel in this area. Please double-click the area frame outside to finish “Cursor Mode”. Cursor mode end Supplement Cross line is displayed by the center in area.
Page 16
IM-A-1332 2020.12 4-4. To store the analysis result? Explain the method to save the analysis result. 1. Please click “All” button from “Result Save” menu. All the analysis results are stored. Supplement Save to “AnalysisFolder\OfflineAnalysis(Result)\” folder. When click “Analysis Result” button, only analysis result is stored, name as follows. ...
Page 17
IM-A-1332 5. Trouble 2020.12 5-1. What is the trouble? It occurs during analysis and expresses that you cannot continue the analysis. At the time of the occurrence, the following “Trouble display” screen is displayed. “Trouble display” screen When the trouble occurs, please click “Reset” button, after evading the trouble, revise the trouble, re-analysis.