Aira HPI-BT-40-1.0 Installation Manual

Aira HPI-BT-40-1.0 Installation Manual

Buffer tanks

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the HPI-BT-40-1.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aira HPI-BT-40-1.0

  • Page 2: Table Of Contents

    Transportation & Storage .................................. 7 Remove old products ..................................7 Clean the existing heating system ..............................7 Install the Aira Indoor Unit ................................7 Mount the buffer tank ..................................7 Connect the water pipes to the buffer tank ..........................8 Install the heating system piping and the outdoor unit ......................
  • Page 3: Introduction

    Welcome to your heat pump system Congratulations on switching to clean, green home costs and produce less CO than a traditional heating. Your Aira heat pump will cut your energy heating system using oil or gas. A+++ Aira Intelligence The highest possible energy class rating Ultra-connected &...
  • Page 4: Safety

    • Check all products for transportation damage and contact Aira Customer Service if any damage is discovered. • If a leak is detected, immediately shut off the water supply and protect the surroundings that 2.2 Warning...
  • Page 5: Product Information

    The hot water for the home’s radiators and underfloor heating is stored in the buffer tank. A buffer tank is always used in an Aira installation to increase system reliability, increase the hot water volume, reduce knocking noises due to...
  • Page 6: Product Overview

    AIRA BUFFER TANKS ½ 3.3 Product overview 1. Temperature sensor 2. Thermometer 3. Drainage 4. & 5. One connection from the heating/cooling zones and one connection to the indoor unit (reversible) 6. & 7. One connection from the heating/cooling zones and one connection to the indoor unit (reversible) 8.
  • Page 7: Installation

    It is critical to ensure that the heating system is cleaned from residue particles before installing the Aira heat pump system with an existing heating system. Fix the bracket to the wall by using 16 screws 4.4 Install the Aira Indoor Unit combined with plugs if needed.
  • Page 8: Connect The Water Pipes To The Buffer Tank

    100 L buffer tank. Use the supplied temperature the buffer tank to facilitate any future service. Use sensor and extension cable for the installation. the recommenced pipe sizes in the Aira Indoor Installation Manual. 4.6.1 Magnetite filter A magnetite particle filter must be installed on the...
  • Page 9: Connect The Buffer Tank To The Indoor Unit

    All cables must be properly secured into place. 4.11 Commissioning All installation steps in the heat pump system installation must have been carried out and inspected before commissioning starts. Commission the heat pump system by following the instruction in the Aira Indoor Unit Installation Manual.
  • Page 10: Service & Maintenance

    The owner outlet, or other electrical connection is loose or will be notified via a push notification from the Aira broken and immediately contact Aira customer app. When the app is opened, a prompt to contact support.
  • Page 11: End Of Use

    Care for the environment! No part of the heat pump system is allowed to be discarded with household waste! These products contain electrical or electronic components that should be recycled. Contact Aira customer support, or the local service office responsible for the installation, for environmentally safe recycling.
  • Page 12 Web. http://www.airahome.com E-mail: info@airahome.com © Aira Group AB This instruction manual is owned by Aira Group AB and may not be copied or reproduced without written consent from Aira Group AB. Aira Group AB reserves the right to make changes.

This manual is also suitable for: