Summary of Contents for Cino FUZZYSCAN SE380 Series

  • Page 1 OEM SCAN ENGINE Programming Manual International Edition, Rev. A6...
  • Page 2 Revision History Rev. No. Released Date Description Rev. A May 26,2010 First Release Page 16 Add “UPC/EAN Security Level” Rev. A1 Jun. 18,2010 Page 38 Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode" and change the default value from 5 seconds to immediate. Page 36 Cancel”...
  • Page 3 © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication.
  • Page 4 Table of Contents Getting Started Getting Familiar with Your FuzzyScan Configure Your FuzzyScan Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Control Keyboard Interface Control Serial Interface Control Wand/Laser Emulation Control Operation Control Condensed DataWizard Appendix Symbology ID Table Keyboard Function Code Table ASCII Input Shortcut Host Interface Quick Set...
  • Page 5 Getting Started Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan SE380 Series Scan Engine. The OEM miniature decoded out scan engine is designed for easy integration into devices which need scanning capability. It delivers superior reading performance, reliability and durability.
  • Page 6 Getting Started Bar Code Programming Menu The FuzzyScan bar code commands are specially designed System Command System Command System Command System Command Proprietary bar code labels which allow you to set the The System Command is the highest level bar code FuzzyScan internal programming parameters.
  • Page 7 Getting Started Programming Procedures Programming Procedures Programming Procedures Programming Procedures As you scan the bar code command to select the desired If the programming family must take multiple scans parameters, information about the final selected parameters selection, cycling scan selection, or dual level selection represented by the bar code commands are stored in the procedures, the family of the programming menu will be FuzzyScan’s internal Flash Memory ASIC or non-volatile...
  • Page 8 Getting Started Program & End Program & End Program & End Program & End System List, Group & Master Default System List, Group & Master Default System List, Group & Master Default System List, Group & Master Default Scan Scan “SYSLIST”...
  • Page 9 Getting Started Single scan selection Single scan selection Single scan selection Single scan selection Multiple scans selection Multiple scans selection Multiple scans selection Multiple scans selection Scan Scan “PROGRAM” Enter programming mode. “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan Scan...
  • Page 10 Getting Started Cycling scan selection Cycling scan selection Cycling scan selection Cycling scan selection Dual level selection Dual level selection Dual level selection Dual level selection Scan Scan “PROGRAM” Enter programming mode. “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan Scan...
  • Page 11 Getting Started Host Interface Selection PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Standard/TTL RS-232 peer-to-peer serial Host Interface Selection Wand emulation USB Com Port Emulation Laser emulation USB HID standard mode USB HID turbo mode...
  • Page 12 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ User Defined Symbol ID ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Code 128 (default=B) (1 character) Symbol ID : 1 character UCC/EAN-128 (default=C) (1 character) UPC-A (default=A) (1 character)
  • Page 13 Symbology ID Transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CINO symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission...
  • Page 14 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ Readable Bar Code Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Auto Readable Symbology Setting Code 128 * UPC-A * UPC-E * EAN-13 * EAN-8 * Codabar/NW-7 * Code 39 * Trioptic Code 39...
  • Page 15 Getting Started Symbology Reading Control Code 39/Code 32 Setting ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Code 39 Code 39 Family Setting Enable Code 39 Select Standard Code 39 as primary format Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission...
  • Page 16 Getting Started Symbology Reading Control Code 39 Setting ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Level 0 Code 39 Security Level Level 1 Level 2 Level 3 Code 39 Security Level The scanner offers four levels of decode security for Code39 bar codes: Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec.
  • Page 17 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ Codabar/NW-7 Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Codabar Codabar Setting Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission...
  • Page 18 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ UPC-A & UPC-E Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable UPC-A UPC Family Setting Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization...
  • Page 19 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ UPC-A & UPC-E Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Select UPC without supplement digits UPC Supplement Setting Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2/5 supplement digits Disable force supplement digits output...
  • Page 20 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ EAN Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable EAN-13 EAN Setting Enable EAN-13 Disable EAN-8 Enable EAN-8 Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN-13 check digit transmission Enable EAN-13 check digit transmission Disable EAN-8 check digit transmission...
  • Page 21 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ EAN Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Level 0 UPC/EAN Security Level Level 1 Level 2 Only available for UPC-A & EAN-13 Disable all specific prefix supplement digital output EAN Supplement Control Enable all specific prefix supplement digital output Enable 491 Supplement Digit Output...
  • Page 22 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ UCC Coupon Extended Code Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable UCC Coupon Extended Code UCC Coupon Extended Code Enable UCC Coupon Extended Code UCC Coupon Extended Code When UCC coupon extended code function is enabled, engine decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99”...
  • Page 23 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ IATA & Interleaved 2 of 5 Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable IATA IATA Setting Enable IATA Select 15-digit fixed length IATA checking Select variable length IATA Disable check digit verification Enable check digit automatic verification...
  • Page 24 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ Code 25 Family Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Standard/Industrial 2 of 5 Code 25 Setting Enable Standard/Industrial 2 of 5 Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable China Postal Code Enable China Postal Code...
  • Page 25 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ Code 11 & Code 93 Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Code 11 Code 11 Setting Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission...
  • Page 26 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ MSI/Plessey Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable MSI/Plessy MSI/Plessey Setting Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission...
  • Page 27 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ Code 128 & UCC/EAN 128 Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Code 128 and UCC/EAN-128 Code 128/EAN-128 Setting Enable Code 128 and UCC/EAN-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off...
  • Page 28 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ UK/Plessey Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable UK/Plessey UK/Plessey Setting Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission...
  • Page 29 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ Telepen Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Telepen Telepen Setting Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Default (04) Telepen Min.
  • Page 30 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ GS1 DataBar Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable GS1 DataBar (RSS-14) GS1 DataBar Setting Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded...
  • Page 31 Getting Started Symbology Reading Control ♦ ♦ ♦ ♦ Linear-stacked & Korea Post Code Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable composite codes Composite Codes Setting Enable composite codes UPC Composite Mode: UPC never linked UPC Composite Mode: UPC always linked Disable PDF417 PDF417/MicroPDF417 Setting...
  • Page 32 Getting Started Keyboard Interface Control ♦ ♦ ♦ ♦ Keyboard Layout (Language) Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code USA (QWERTY) Keyboard Layout France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (Spanish, QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY)
  • Page 33 Getting Started Keyboard Interface Control ♦ ♦ ♦ ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None Record Suffix RETURN SPACE ENTER (Numeric Key Pad) User defined character (1 character) 5, (00-7F) None Preamble...
  • Page 34 Getting Started Keyboard Interface Control ♦ ♦ ♦ ♦ Delay Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None Intermessage Delay 1-99 (x5) msec. (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
  • Page 35 Getting Started Keyboard Interface Control ♦ ♦ ♦ ♦ Emulation Setting & Upper/Lower Case Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Enable ASCII 00-31 code as keyboard function code output Function Key Emulation Ctrl-Output Refer to Appendix –...
  • Page 36 Getting Started Serial Interface Control ♦ ♦ ♦ ♦ Record Suffix, Preamble ,Postamble Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable STX/ETX transmission STX/ETX Control Enable STX/ETX transmission STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
  • Page 37 Getting Started Serial Interface Control ♦ ♦ ♦ ♦ Delay Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None Intermessage Delay 1-99 (x5) msec. (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
  • Page 38 Getting Started Serial Interface Control ♦ ♦ ♦ ♦ Protocol, ACK/NAK Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None (free running mode) Handshaking Protocol RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) 3 times NAK Retry Count 0~255 times...
  • Page 39 Getting Started Serial Interface Control ♦ ♦ ♦ ♦ Time Out Setting, Baud Rate, Data Frame ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None 1 second Serial Response Time-out 200 mseconds 2 seconds 500 mseconds 5 seconds User defined value (seconds) 6, (2 digits)
  • Page 40 Getting Started Wand/Laser Emulation Control ♦ ♦ ♦ ♦ Output Polarity, Signal State, Margin/Module Time, etc. ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code High level (5Vdc) on Bar (low level on Space) Output Polarity Low level (0Vdc) on Bar (high level on Space) Determine the output voltage level for both bar and space.
  • Page 41 Getting Started Operation Control ♦ ♦ ♦ ♦ Operation Mode Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Low Power mode Operation Mode Trigger mode Presentation mode Alternative mode Force mode (L680/L780 laser imagers don’t support this mode.) Level mode Lower Power Mode (Low Power Triggering) When the engine receives an external trigger or a serial trigger ON command under trigger mode, the engine will turn on the light source to read barcode until gets a good read, a serial trigger OFF command or a release of external trigger.
  • Page 42 Getting Started Operation Control ♦ ♦ ♦ ♦ Buzzer, Indicator, Inverse Reading, Dollar Sign♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Buzzer tone – mute Buzzer Tone Adjust Buzzer tone – low Buzzer tone – medium Buzzer tone –...
  • Page 43 Getting Started Operation Control ♦ ♦ ♦ ♦ Redundancy, Scan Rate Control ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None Redundancy Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading. Dynamic Scan Rate Control Fixed...
  • Page 44 Getting Started  Operation Control ♦ ♦ ♦ ♦ Delay Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Reread Delay Disable Immediate time out (Double Scan Verification) Short time out Medium time out Long time out Force verification None Good Read Delay...
  • Page 45 Getting Started Operation Control ♦ ♦ ♦ ♦ Time-out Setting, Good Read Beep Duration ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 100 msec. 600 msec. Scan Input Time-out 200 msec. 700 msec. 300 msec. 800 msec.
  • Page 46 Getting Started Operation Control ♦ ♦ ♦ ♦ Presentation Scanning Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Presentation Auto-sense Enable Level 1 Presentation Sensitivity Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 When enable the Presentation Auto-sense, the engine can be switched between hands free scanning and hand-held scanning automatically when working with the...
  • Page 47 Getting Started Condensed DataWizard ♦ ♦ ♦ ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code None Preamble 1-15 characters [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. None Postamble 1-15 characters...
  • Page 48 Getting Started Condensed DataWizard ♦ ♦ ♦ ♦ Data Formatter Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Formatter Control Select one bar code symbology automatic termination (2 digits) Select all bar code symbologies automatic termination Disable 1st Insertion...
  • Page 49 Getting Started Condensed DataWizard ♦ ♦ ♦ ♦ Data Verifier Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Verifier Control Select one bar code symbology (2 digits) automatic termination Select all bar code symbologies automatic termination Disable Identified Data Length...
  • Page 50 Getting Started Condensed DataWizard ♦ ♦ ♦ ♦ Data Replacer Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Replacer Control Select one bar code symbology automatic termination (2 digits) Select all bar code symbologies automatic termination Disable 1st Replacement...
  • Page 51 Getting Started Condensed DataWizard ♦ ♦ ♦ ♦ Data Organizer Setting ♦ ♦ ♦ ♦ PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code 2nd Option Code Disable Organizer Control Select one bar code symbology automatic termination (2 digits) Select all bar code symbologies automatic termination Disable 1st Organization...
  • Page 52 Getting Started [Data Verifier, Data Replacer, Data Organizer] Select a Bar Code Symbology Select a Bar Code Symbology Select a Bar Code Symbology Select a Bar Code Symbology If there is a 11-character data string, please refer to the You can select one or all types of bar code symbologies to following to calculate the actual position for identification.
  • Page 53 Getting Started Programming Procedure Programming Procedure Programming Procedure Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Replacer Control” and set bar code symbology to “48”. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5).
  • Page 54 Getting Started Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character Cino ID AIM ID Cino ID AIM ID Code Family Primary Format Code Family...
  • Page 55 Getting Started Keyboard Function Code Table ANSI ASCII Key Function ANSI ASCII Key Function RESERVED CTRL (Left) ALT (Left) SHIFT CAPS LOCK NUM LOCK INS (Insert) (Edit) DEL (Delete) (Edit) BACK SPACE HOME (Edit) END (Edit) PAGE UP (Edit) PAGE DOWN (Edit) UP (Edit) ENTER (CR) DOWN (Edit)
  • Page 56 Getting Started ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via HEX/ASCII Reference Table programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. SPACE Example: "...
  • Page 57 Getting Started Host Interface Quick Set RS232 Serial USB Com Port Emulation USB HID Standard Mode USB HID Turbo Mode...
  • Page 58 Getting Started Operation Mode Quick Set Lower Power (Low power trigger) Level (Auto power off) Presentation (Auto sensing) Trigger (External triggering) Force (Continued power on) Alternative (Periodic power off)
  • Page 59 Getting Started Option Codes FIN (Finish) END (Exit)
  • Page 60 Getting Started System Commands PROGRAM System Information List (Enter Programming Mode) (SYSLIST) Save User Default FIN (Finish) PowerTool Host Link User Default Factory Default (Exit Programming Mode) Master Default Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value. Master Default: After scanning “Master Default”...
  • Page 61 Scan Engine Programming Manual CINO GROUP PC WORTH INT’L CO., LTD.

This manual is also suitable for:

Fuzzyscan se380-eva-kit