Download Print this page

Heltec Automation SenseCAP ONE Series Manual

Compact weather sensor

Advertisement

Quick Links

Compact Weather Sensor
Version: V1.1
Dates: 2024-9-5

Advertisement

loading
Need help?

Need help?

Do you have a question about the SenseCAP ONE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Heltec Automation SenseCAP ONE Series

  • Page 1 Compact Weather Sensor Version: V1.1 Dates: 2024-9-5...
  • Page 2 4.2.3 Setting Command Format..........................31 4.2.4 Command List..............................31 SDI-12 ................................... 38 4.3.1 SDI-12 command and response........................38 4.3.2 SDI-12 Read..............................42 5 Error code................................46 5.1 Modbus error code..............................46 Heltec.org Docunments | P2/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 3 Heltec Weather Sensor User manual 5.2 ASCII error code..............................46 5.3 SDI-12 error code..............................46 Heltec.org Docunments | P3/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 4 Heltec Weather Sensor User manual Versio Description Date The modifier V1.0 Initial version 04-07-2023 Jenkin Lu Add new product Introduction V1.1 04-25-2023 Xinan Rao Heltec.org Docunments | P4/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 5 0~60 m/ s standard range ±0.3m/s(≤10m/s); 0.1m/s ±3% ( 10m/s ~ Wind speed 0~75 m/ s extended range 50m/s) ±5% Up to 80 m / s withstand (>50m/s) range Heltec.org Docunments | P5/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 6 0~ 1000µg/m3 1µg/m3 PM10 1000µg/m3 ±15µg/m3@0~ 100µg/m3 Product Model: S1000 (10-in-1,CO2 series) Measurement Parameter Measurement Range Measurement Accuracy Resolution Air temperature -40~85 °C 0.01 °C ±0.1 ℃ Heltec.org Docunments | P6/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 7 10000 Note: Multi-in-one meteorological environment sensors with other monitoring elements can be customized. For specific requirements, please contact relevant personnel of the company. Heltec.org Docunments | P7/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 8 Heltec Weather Sensor User manual 2 Installation Before the installation, check the packing list and make sure there are no missing parts. Heltec.org Docunments | P8/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 9 USB Type-C cable, for configuring devices Flange plate (purchased separately) Pole adapter sleeve base (purchased separately) Pole adapter cross bar (purchased separately) Heltec.org Docunments | P9/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 10 USB Type-C interface allows you to connect your computer with a normal USB Type-C cable to the device for configuration. • The main data interface can be connected to the M12 8- pin cable, supporting multiple bus protocols Bottom of the device Heltec.org Docunments | P10/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 11 2.2.2 Connect with USB Cable Note: The white cover (on the side near the label) should be tightened after debugging to prevent water from entering the device! Heltec.org Docunments | P11/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 12 The holes of the cable and the pins of the device connector must be aligned when the cable is plugged Heltec.org Docunments | P12/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 13 Gray wire #5 is connected to the negative of the power supply, and pink wire #6 is connected to the positive pole of the power supply. Heltec.org Docunments | P13/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 14 2.2.4 Install the device. There are two major installation methods, either mount on a pole with a sleeve or a platform with a flange plate Heltec.org Docunments | P14/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 15 Heltec Weather Sensor User manual The size of the sleeve is shown below. Heltec.org Docunments | P15/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 16 Heltec Weather Sensor User manual It is recommended that the diameter of the pole should be less than or equal to 75cm. Heltec.org Docunments | P16/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 17 Heltec Weather Sensor User manual Note: Please tighten the screws ! The dimension of the flange plate is shown below. Heltec.org Docunments | P17/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 18 Heltec Weather Sensor User manual Heltec.org Docunments | P18/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 19 Connect the devices and data logger with an M12 data and power cable, and then the data collected by the device will be sent to the host Working Mode different communication protocols. Heltec.org Docunments | P19/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 20 After the driver is successfully installed, you can see a serial port in the device's manager. If the driver is not installed automatically, click this link to manually download install driver.( The version is CP210 x Windows Drivers) Heltec.org Docunments | P20/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 21  If you receive the corresponding 0XA message in the serial receive window, the configuration is successful. If not, please check the COM port and the baud rate. Please check the detailed ASIIC command in the next chapter. Heltec.org Docunments | P21/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 22 One start bit, 8 Data bits, None parity, one Stop bits. Data Format 9600bps (default), which can be modified by configuration. Baud Rate 43(CO2 series) S1000 S800 Default Device S700 Address (Decimal) S500 S200 Heltec.org Docunments | P22/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 23 1 byte 1 byte 1 byte 2 bytes 2 bytes 2 bytes 0x03/0x06 CCCC big endian big endian big endian Address 0-247 0x03/0x06 little-endian Heltec.org Docunments | P23/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 24 0~60000 wind speed Average 0x0012 0~60000 wind speed Accumula 0x0014 0~80000000 ted rainfall Accumulate 0x0016 0~2000000000 rainfall duration 0x0018 Rain intensity 0-200000 0x001A Maximum 0-60000 rainfall Heltec.org Docunments | P24/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 25 0. Read duration back 1 to confirm that the to 0 setting is finished. Read back 0 indicates that the setting failed Heltec.org Docunments | P25/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 26 Set the default slave ID(2-in-1 is 44,5-in-1 is 10 ,7-in-1 is 20), function code 04, starting address 0, quantity (2-in-1 is 12 ,5-in-1 is 6 ,7-in-1 is 28); Heltec.org Docunments | P26/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 27 The original code is - (FF FF FC 18-1 = FF FF FC 17) = 80 00 03 E8(Hex) = -1000 (Decimal). Then the temperature measurement is -1000/ 1000 = -1° Heltec.org Docunments | P27/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 28 00 00 00 00(Light) 00 00 00 00(Min wind direction) 00 00 00 00(Max wind direction) 00 00 00 00(Avg wind direction) 00 00 00 00 (Min wind speed) 00 00 00 00(Max wind speed) 00 00 00 00(Avg wind speed) 00 00 00 Heltec.org Docunments | P28/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 29 Read register 0x0040~0x0041. Send command:2B 04 00 40 00 02 77 D5 Return:2B 04 04 00 0C EC 98 ( CO2) FD 2F ( Check code); Heltec.org Docunments | P29/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 30 Example: ?< CR>< LF> indicates query the device’s address 2. A command with = refers to a query with an argument Example: 0XA;BD=?< CR>< LF> indicates query the device’s baud rate Heltec.org Docunments | P30/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 31 Set the communication protocol of device 0 to [cp], if [cp] is 6, the communication protocol is set to Description ASCII text protocol based on the RS-485 bus RS-48 5 address MBAD Heltec.org Docunments | P31/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 32 0XA; RESTORE= 1< CR>< LF> Setting 0XA; RESTORE= 1< CR>< LF> Response Return 0XA; RESTORE= 1 means the setting is successful and return 0XA means the setting fails. Description Heltec.org Docunments | P32/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 33 0 ° C, it may freeze, which will affect the detection of wind speed and direction) Send 0XA;HC=N< CR>< LF> 0XA;HC=N< CR>< LF> Response Set to enable heating function. Description Heltec.org Docunments | P33/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 34 Set the data update interval to 2 seconds, you can choose a value between 1 to 3600 seconds. Description Air Temperature Unit Query Send 0XA; UT=? <CR><LF> Heltec.org Docunments | P34/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 35 M = m/s, K = km/h, S = mph, N = knots The wind direction offset correction value Send 0XA;DO=? <CR>< LF> Query 0XA; DO=0<CR>< LF> Response Heltec.org Docunments | P35/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 36 0XA; AL= 1000<CR><LF> Setting Response 0XA; AL= 1000<CR><LF> When the rainfall is set to 1000 (current unit), the accumulated rainfall will be reset to 0. Description Heltec.org Docunments | P36/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 37 The accumulated rainfall in the past hour, during which the accumulated value is updated every 10s Rainfall until the accumulated time reaches 1 hour intensity (hourly rainfall) Maximum Maximum rainfall per minute in the past hour *60 minutes rainfall intensity Heltec.org Docunments | P37/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 38 Send Response 0<CR>< LF> Description Address '0' of device online Query the device information Send Response 014 SenseCAPONE3.010199069221040 01<CR><LF> Response the device information Description Heltec.org Docunments | P38/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 39 0M2!: Start Rain measurement: accumulated rainfall, accumulated rainfall time, rainfall Description intensity, maximum rainfall intensity. 0M3!: Start Dust measurement: PM2.5, PM10. Heltec.org Docunments | P39/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 40 0R1!: Start Wind continuous measurement: minimum wind direction, maximum wind direction, average wind direction, minimum wind speed, maximum wind speed, average wind speed. 0R2!: Start Rain measurement: accumulated rainfall, accumulated rainfall time, rainfall intensity, Heltec.org Docunments | P40/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 41 Clear success: 1 Clear failed: 0 0XCRD! Clear accumulated rainfall duration Send 0XCRD! Response 01<CR><LF> aN< CR>< LF> Device address:0 Description Clear success: 1 Clear failed: 0 Heltec.org Docunments | P41/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 42  Click to open the serial port.  Send the query device address command "?!", if you can see the response "0", it means the connection is OK. Heltec.org Docunments | P42/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 43 Then send " Read measurement value command 0D0!" to get the 4 measured values this measurement, which are air temperature +27.01℃ , air humidity 64.74%, barometric pressure 100720Pa, and light intensity 10Lux. Heltec.org Docunments | P43/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 44 34 5. 9 degrees, maximum wind direction 34 7 .5 degrees, average wind direction 346.3 degrees, minimum wind speed 2.8m/s, and maximum wind speed 2.8m. /s, average wind speed 2.8m/s. Heltec.org Docunments | P44/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 45 Then send “continuous measurement command 0R2!, the device returns 4 measured values: cumulative rainfall 1.2mm, cumulative rainfall duration 20 seconds, rainfall intensity 1.2mm/h, maximum rainfall intensity 72.0mm/h. Heltec.org Docunments | P45/46 | September 5 | Heltec Automation © Limited Standard files...
  • Page 46 Sensor probe exception 0XA;AT=#4 SDI-12 error code Error code Description Response instance Device do not response 2001001 0+2001001+2001001+2001001+2001001<CR><LF> Sensor probe exception 2001004 0+2001004+2001004+2001004+2001004<CR><LF> Heltec.org Docunments | P46/46 | September 5 | Heltec Automation © Limited Standard files...