A.O. Smith SBT 300 Installation, User And Service Manual
A.O. Smith SBT 300 Installation, User And Service Manual

A.O. Smith SBT 300 Installation, User And Service Manual

Thermal store buffervat
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

SBT
IT
Indirecte boiler
Thermal Store
Indirect calorifier
Buffervat
Ballon échangeur
300/500/750/1000/1500
2000/2500/3000/4000/5000
IT 1500/2000/2500/3000
Installatie-, Gebruikers- en Servicehandleiding
Installation, User and Service Manual
Installation, User and Service Manual
Installatie-, Gebruikers- en Servicehandleiding
Manuel d'installation, d'utilisation et d'entretien

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBT 300 and is the answer not in the manual?

Questions and answers

Summary of Contents for A.O. Smith SBT 300

  • Page 1 Thermal Store Indirecte boiler Buffervat Indirect calorifier Ballon échangeur 300/500/750/1000/1500 2000/2500/3000/4000/5000 IT 1500/2000/2500/3000 Installation, User and Service Manual Installatie-, Gebruikers- en Servicehandleiding Installatie-, Gebruikers- en Servicehandleiding Installation, User and Service Manual Manuel d'installation, d'utilisation et d'entretien...
  • Page 2 Data is subject to change / Gegevens onderhevig aan verandering A.O. Smith Europe De Run 5305 PO Box 70 T : +31 (0)40 294 2500 5500 AB Veldhoven info@aosmith.com The Netherlands www.aosmithinternational.com...
  • Page 3: Table Of Contents

    English Preface ..................................4 INTRODUCTION ............................. 8 SAFETY GUIDELINES ............................8 TECHNICAL DETAILS ............................9 GENERAL REQUIREMENTS ..........................12 WATER QUALITY ............................12 WATER CONNECTIONS ..........................12 COMMISSIONING AND TESTING ........................13 USER INSTRUCTIONS ............................13 MAINTENANCE ............................14 10.0 WARRANTY ..............................15 11.0 APPENDIX ..............................17 Nederlands Voorwoord ................................21 INLEIDING ..............................25 VEILIGHEIDSRICHTLIJNEN ..........................25...
  • Page 4: Preface

    Liability A.O. Smith Water Products Company accepts no liability for claims from third parties arising from unauthorised use, use other than that stated in this manual, and use other than in accordance with the General Conditions registered at the Chamber of Commerce.
  • Page 5 Document indentification Article number Language Version 0338217 0338217_SBT_ENNL_V1.0, 2024-07-08...
  • Page 6 Table of contents Preface ..................................4 INTRODUCTION ............................. 8 SAFETY GUIDELINES ............................8 General description of safety symbols used ........................8 General ....................................8 TECHNICAL DETAILS ............................9 COOLING SYSTEMS ................................9 DIMENSIONS AND CONNECTION SIZES ..........................10 3.2.1 Dimensional drawing..............................10 3.2.2 Dimensions ..................................10 3.2.3 Connection sizes [all female] ............................11 GENERAL REQUIREMENTS ..........................12...
  • Page 7 10.3 Conditions for installation and use ...........................15 10.4 Exclusions ..................................15 10.5 Scope of the warranty ..............................16 10.6 Claims ....................................16 10.7 Obligations of A.O. Smith ..............................16 11.0 APPENDIX ..............................17 11.1 DECLARATION OF CONFORMITY ............................17 11.2 ERP DATA TABLE ................................18 0338217_SBT_ENNL_V1.0, 2024-07-08...
  • Page 8: Introduction

    This symbol shows essential information which is not safety related General A.O. Smith is not liable for any damage caused by inaccurately following these mounting instructions. Only original parts may be used when carrying out any repair or service work.
  • Page 9: Technical Details

    TECHNICAL DETAILS Note: Suitable for both heating and cooling projects Unit Description SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 litres Storage Capacity 1000 1500 Empty Weight Floor Load (weight unit + storage capacity) 1130 1718 Maximum Working Pressure Tank °C...
  • Page 10: Dimensions And Connection Sizes

    DIMENSIONS AND CONNECTION SIZES 3.2.1 IMENSIONAL DRAWING 3.2.2 IMENSIONS Description Unit SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 Total Height (with insulation) 1680 1735 1765 2075 2245 Diameter of Water Heater (with insulation) 1010 1220 Height of Heating system flow connection...
  • Page 11: Connection Sizes [All Female]

    3.2.3 ONNECTION SIZES ALL FEMALE Description Unit SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 Connection Heating System Flow 2" 3" 3" 3" 3" Connection Tank body 1½" 2" 2" 2" 2" Connection Sensor Point ½" ½" ½"...
  • Page 12: General Requirements

    GENERAL REQUIREMENTS The A.O. Smith SBT thermal store has been designed to operate trouble free for many years. These instructions should be followed closely to obtain the maximum usage and efficiency of the equipment. PLEASE read the instructions fully before installing or using the appliance. These instructions should be read in conjunction with the appropriate Heat pump installation manual.
  • Page 13: Commissioning And Testing

    COMMISSIONING AND TESTING Electrical Installation Any ancillary item that requires an electrical supply should be installed and commissioned as per instructions. Water Connection For design, see Section 6: Water connections The system should be thoroughly flushed out with water without any circulating pumps in position. Ensure all the valves are open.
  • Page 14: Maintenance

    MAINTENANCE General Regular servicing is required, to ensure trouble free operation. Even if a maintenance schedule is determined to be less than annually, it is important that all controls and safety features be checked for correct operation on an annual basis.
  • Page 15: 10.0 Warranty

    If within two years of the original installation date of a buffer tank supplied by A.O. Smith, following verification, and at the sole discretion of A.O. Smith, an assembly or part (with exclusion of the tank) proves to be defective or fails to function correctly due to manufacturing and/or material defects, then A.O.
  • Page 16: Scope Of The Warranty

    A claim on grounds of the specified warranty must be submitted to the dealer from whom the buffer tank was purchased, or to another authorised dealer for A.O. Smith Water Products Company products. Inspection of the buffer tank as referred to in articles 1 and 2 shall take place in one of the laboratories of A.O. Smith. 10.7 Obligations of A.O.
  • Page 17: Appendix

    APPENDIX 11.0 11.1 DECLARATION OF CONFORMITY Conditions of use: 1. The installation instructions have been followed 2. Fluids being passed through the heat exchanger are non-hazardous in the group 2 category 3. The maximum working pressures and temperatures as noted on the equipment data plate are not exceeded. 0338217_SBT_ENNL_V1.0, 2024-07-08...
  • Page 18: Erp Data Table

    11.2 ERP DATA TABLE Only applicable for hot water tank up to 2000 litres. Value Information Unit A.O. Smith Trade mark Model Identifier SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 SBT 2000 Energy efficiency class Standing loss 65.5...
  • Page 19 0338217_SBT_ENNL_V1.0, 2024-07-08...
  • Page 21: Nederlands

    A.O. Smith Water Products Company. A.O. Smith Water Products Company behoudt zich het recht voor de specificaties zoals vermeld in deze handleiding te wijzigen.
  • Page 22 Document aanduiding Artikelnummer Taal Versie 0338217...
  • Page 23 Inhoudsopgave Voorwoord ................................21 INLEIDING ..............................25 VEILIGHEIDSRICHTLIJNEN ..........................25 Algemene beschrijving van de gebruikte veiligheidssymbolen ..................25 Algemeen ..................................25 TECHNISCHE INFORMATIE ..........................26 KOELSYSTEMEN ................................26 AFMETINGEN EN AFMETINGEN AANSLUITINGEN ......................27 3.1.1 Maattekening ................................27 3.1.2 Afmetingen ..................................27 3.1.1 Afmetingen aansluitingen [allen inwendig].........................28 ALGEMENE EISEN ............................29 WATER KWALITEIT ............................29 Buffervat ...................................29 WATER AANSLUITINGEN ..........................29...
  • Page 24 Garantie Algemeen ................................32 10.2 Garantie Tank ...................................32 10.3 Voorwaarden installatie en gebruik ..........................32 10.4 Uitsluitingen ..................................32 10.5 Omvang Garantie ................................33 10.6 Claims ....................................33 10.7 Verplichtingen voor A.O. Smith ............................33 11.0 BIJLAGE ................................34 11.1 CONFORMITEITSVERKLARING ............................34 11.2 ERP - GEGEVENS TABEL ..............................35...
  • Page 25: Inleiding

    INLEIDING • De SBT is een thermisch buffervat voor gebruik met hernieuwbare energie om energie in op te slaan. • Er moet voor worden gezorgd dat aan alle veiligheidseisen wordt voldaan voor omstandigheden met hoge of lage druk in het syteem. VEILIGHEIDSRICHTLIJNEN Lees zorgvuldig alle instructies door voordat u met de installatie begint.
  • Page 26: Technische Informatie

    TECHNISCHE INFORMATIE Opmerking: Geschikt voor zowel verwarmings- als koelprojecten Eenheid Omschrijving SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 liter Opslag Capaciteit 1000 1500 Ledig Gewicht Vloerbelasting (ledig gewicht + opslag capaciteit) 1130 1718 Maximale Werkdruk Tank °C Minimale Temperatuur Tank °C...
  • Page 27: Afmetingen En Afmetingen Aansluitingen

    AFMETINGEN EN AFMETINGEN AANSLUITINGEN 3.1.1 AATTEKENING 3.1.2 FMETINGEN Omschrijving Eenheid SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 Totale Hoogte (incl. isolatie) 1680 1735 1765 2075 2245 Diameter Tank (incl. isolatie) 1010 1220 Hoogte Warmwateruitlaat 1405 1450 1445...
  • Page 28: Afmetingen Aansluitingen [Allen Inwendig]

    3.1.1 FMETINGEN AANSLUITINGEN ALLEN INWENDIG Omschrijving Eenheid SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 Aansluiting Warmwateruitlaat 2" 3" 3" 3" 3" Aansluiting Tank 1½" 2" 2" 2" 2" Aansluiting Sensor ½" ½" ½" ½" ½" Aansluiting Tank 1½"...
  • Page 29: Algemene Eisen

    ALGEMENE EISEN Het A.O. Smith SBT thermische buffervat is ontworpen om vele jaren probleemloos te functioneren. Deze instructies moeten nauwkeurig worden gevolgd om een maximaal gebruik en maximale efficiëntie van de apparatuur te verkrijgen. Lees EERST de instructies volledig door voordat u het apparaat installeert of gebruikt. Deze instructies moeten samen met de betreffende installatiehandleiding voor de warmtepomp worden gelezen.
  • Page 30: Onderhoud En Testen

    ONDERHOUD EN TESTEN Electrische Installatie Elk bijkomend item dat een elektrische voeding nodig heeft, moet worden geïnstalleerd en in bedrijf gesteld volgens de instructies. Water Aansluitingen Voor ontwerp, zie Hoofdstuk 6: Water aansluitingen Het systeem moet grondig worden doorgespoeld met water zonder dat er circulatiepompen zijn geplaatst.
  • Page 31: Onderhoud

    ONDERHOUD Algemeen Regelmatig onderhoud is vereist om een probleemloze werking te garanderen. Zelfs als wordt vastgesteld dat het onderhoudsschema minder dan jaarlijks bedraagt, is het belangrijk dat alle bedieningselementen en veiligheidsvoorzieningen jaarlijks worden gecontroleerd op correcte werking. Onderhoudsschema Het is een goede gewoonte om de SBT elke 12 maanden te controleren. Overige Controles 9.3.1 NTLUCHTINGSKLEP...
  • Page 32: Garantie

    Indien binnen drie jaar na de oorspronkelijke installatiedatum van een door A.O. Smith geleverd buffervat, na onderzoek en ter uitsluitende beoordeling van A.O. Smith, blijkt dat de stalen tank lekt ten gevolge van roest of corrosie vanuit de waterzijdige kant, zal A.O. Smith een volledig nieuw buffervat van gelijkwaardige grootte en kwaliteit ter beschikking stellen.
  • Page 33: Omvang Garantie

    Een claim gebaseerd op de gegeven garantie moet worden gedeponeerd bij de handelaar bij wie het buffervat is gekocht of bij een andere handelaar die de producten van A.O. Smith Water Products Company verkoopt. Het onderzoek van het buffervat bedoeld in de artikelen 1 en 2 zal plaatsvinden in een laboratorium van A.O. Smith. 10.7 Verplichtingen voor A.O.
  • Page 34: Bijlage

    BIJLAGE 11.0 11.1 CONFORMITEITSVERKLARING Gebruiksvoorwaarden: 1. De installatie-instructies worden gevolgd. 2. Vloeistoffen die door de warmtewisselaar worden geleid, zijn niet gevaarlijk in de categorie groep 2. 3. De maximale werkdrukken en temperaturen zoals vermeld op het typeplaatje van de apparatuur worden niet overschreden.
  • Page 35: Erp - Gegevens Tabel

    11.2 ERP - GEGEVENS TABEL Geldt alleen voor warmwatertanks tot 2000 liter. Waarde Informatie Eenheid A.O. Smith Merknaam Model SBT 300 SBT 500 SBT 750 SBT 1000 SBT 1500 SBT 2000 Energie-efficiëntie klasse Stilstandsverlies 65.5 114.1 132.7 125.4 149.5 190.7...