GETTING STARTED GUIDE
Thank you for purchasing KYOWA's product PCD-400B/430B Sensor Interface.
Read this GETTING STARTED GUIDE carefully in order to make full use of the high-performance capabilities of the product.
Do not use the product in methods other than described in this Getting Started and Manual.
The standard accessory DVD includes instruction manuals.
 STANDARD ACCESSORIES
The following accessories are packed with the PCD-400B/430B.
When unpacking, check the contents to ensure that all accessories are enclosed.
Dynamic Data Acquisition Software (DCS-100A)
1 (DVD)
USB cable (N-38:1 m)
1
Ground wire (P-72)
1
Test Certificate and Warranty
1 each
 OPTIONAL ACCESSORIES
AC adapter
UNI360-1540-AC
USB cable
N-39(2 m)
DC power cable
P-76(2 m)
Connection cable
N-97(10 cm)
Stacking kit
ST-1B
Input adapter for strain gage transducer
UI-10A(TEDS supported)
Input adapter for strain gage
UI-11A(TEDS supported)
Input adapter for strain gage with operating lever
UI-15A
One-touch type input adapter for strain gage
UI-16B
One-touch type input adapter
UI-55A
Input adapter for voltage
UI-30A
Data Analysis Software
DAS-200A
 SAFETY PRECAUTIONS (Do not forget to read the safety precautions prior to use.)
The PCD-400B/430B is designed to be used according to "8. Specifications." Do not use the PCD-400B/430B in an environment exceeding the specifications. Or, it may cause trouble.
・PRIOR TO USE
For safe use of the PCD-400B/430B, do not forget to read the "Safety Precautions" prior to use.
Kyowa Electronic Instruments Co., Ltd. assumes no liability for any damage resulting from the user's failure to comply with the safety precautions.
For safety operation of the PCD-400B/430B, the following symbol mark is attached to the PCD-400B/430B.
Indicates "GROUND TERMINAL."
Be sure to connect the GND terminal to the ground.
Indicates the operator must refer to an explanation in the INSTRUCTION MANUAL in order to avoid the risk of injury or death of personnel or damage to
the instrument.
・ SAFETY SYMBOLS
For safety operation of the product, the following symbol marks are used in the Instruction Manual.
WARNING
Improper operation of the system may result in death or severe injury of the operator.
CAUSION
Improper operation of the system may result in injury of the operator and physical damage of the system.
IM-A-1459B August 2023
Warning
Be sure to observe the warning and precautions described in the PCD-400B/430B Instruction Manual (FOR HARDWARE).
Power supply
PCD-400B/430B
To prevent a fire hazard, ensure that the power supply voltage specified for the PCD-400B/430B (11 to 16 VDC) matches the local line voltage before connecting the system to the DC
power. When using the optional AC adapter, check the voltage range of the AC power outlet before connecting.
SENSOR INTERFACE
Avoid using in environment with inflammable gas, etc.
To prevent the risk of fire hazard or explosion, do not use the PCD-400B/430B in environment with inflammable gas, vapor, or dust.
If any trouble occurs
To prevent a fire hazard, if smoke is emitted from the PCD-400B/430B, immediately disconnect the AC adapter from the receptacle and stop using the PCD-400B/430B.
Ground
Be sure to connect the GND terminal to the ground. Or, it may cause an electric shock hazard, lower the performance, and cause trouble.
Causion
Be sure to observe the safety precautions described in the PCD-400B/430B Instruction Manual (FOR HARDWARE).
Do not use the PCD-400B/430B outdoors.
Or, it may cause electric shock, fire hazard, lower the performance and cause troubles.
Do not turn ON the power switch immediately after turning it OFF.
After turning OFF the power switch, wait (5 seconds) until the power supply is shut OFF before turning ON the power switch again. If the power is repeatedly turned ON and OFF within 5
seconds, rush current generated by switching the power ON may damage the product.
Avoid measuring object applied with high voltage in strain measuring mode.
Although the PCD-400B/430B is insulated, if it is used for measuring objects with excessive high voltage, it may deteriorate its performance and cause trouble.
Always input voltage within allowable voltage range of ±50 V in voltage measuring mode.
When measuring object in voltage measuring mode, do not input voltage lower then -50 V or higher than +50 V. The PCD-400B/430B is not insulated in voltage measuring mode. If
voltage exceeding the allowable voltage range (+50 V) is input, performance of product may be deteriorated and cause trouble.
Use the PCD-400B/430B within temperature ranging from 0 to 40 ℃.
Use at temperatures exceeding the specified range may lower the performance and cause trouble. If use under
proper measures to keep it warm.
Use in an environment with a humidity of 20 to 85 % (no condensation).
Use in a humid place exceeding the specified range or where it is exposed to splashing water may lower the performance and cause trouble.
Do not use the product immediately after the change in the environment.
Leave the PCD-400B/430B as it is until it becomes adaptable to the environment. Abrupt change in ambient temperature due to transportation, etc. may cause dew condensation, which
may result in lower performance and troubles.
Do not use the PCD-400B/430B under dusty environment.
This can lead to performance problems and decreased operating efficiency. Be careful that dust may not enter the PCD-400B/430B not only during operation but also under stored
conditions.
Use the PCD-400B/430B under environment without excessive vibration or high impact.
Vibration resistance:29.42 m/s
Use the PCD-400B/430B in an area where vibration and impact can be kept within the scope of specifications.
Continuous vibration or severe impact may cause deteriorated performance and system failure.
Do not use the PCD-400B/430B in strong electromagnetic field.
Use the PCD-400B/430B in a magnetic field environment where the PC may be used. Performance may be lowered and erroneous operation and troubles may result if it is used near a
telemetry system, microwave oven, electronic furnace or any other equipment generating a strong magnetic field.
Do not use the PCD-400B/430B under poor conditions.
When using a DC power supply, use within the range of 11 to 16 V DC. When using the optional AC adapter (UNI360-1540-AC), use within the range of 100 to 240 V AC (50/60 Hz). Use
a power supply that is free from momentary power failures and noise.
The specifications of the optional AC adapter (UNI360-1540-AC) is as follows.
Input voltage:AC100 ~ 240 V (50/60 Hz)
Output voltage:15 V (4.0 A)
Operating temperature range:0 ~ 40 ℃
*This AC adapter has a limited life. Please purchase a new product after about 5 years.
Do not pull cords and cables.
Lay cords and cables with a certain allowance so that any unreasonable force is applied to the connections. Pulling or applying unreasonable force may cause trouble or interrupt the
measurement.
Avoid installing sensors and PCD-400B/430B near a welding machine.
Failure to do so will pose the risk of erroneous data, malfunction and failure.
Do not disassemble or remodel the PCD-400B/430B. Or, it may cause electric shock hazards or damage the PCD-400B/430B. This warranty does not cover any damaged or defective parts
that results from disassembling or remodeling.
Handle the DVD with care.
Do not expose the DVD to direct sun light, high temperature, or high humidity.
Do not apply pressure to the DVD by laying object or bending.
Dust, scratches, and fingerprints on either side of the DVD can cause write errors.
Preheat the PCD-400B/430B before use.
To ensure accurate measurements, allow approximately one hour of warm-up time after turning on the power before starting measurements.
1
WARINIG
CAUSION
2
(3 G), 5 to 200 Hz (unstacked)
direct sunlight or in a cold place is inevitable, prepare a sunscreen or take

Advertisement

loading
Need help?

Need help?

Do you have a question about the PCD-400B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KYOWA PCD-400B

  • Page 1 ● To prevent a fire hazard, ensure that the power supply voltage specified for the PCD-400B/430B (11 to 16 VDC) matches the local line voltage before connecting the system to the DC power. When using the optional AC adapter, check the voltage range of the AC power outlet before connecting.
  • Page 2 The PCD-400B/430B is provided with input adapters applicable for the sensors. Since the PCD-400B/430B is capable of measurement of 4 channels per a unit and maximum 16 channels with 4 units, the PCD-400B/430B is applicable for measurement in a wide range ...

This manual is also suitable for:

Pcd-430b