Download Print this page

Avalue Technology HPM-SIEUA User Manual

Amd single 4th generation epyc 8004 processor atx server board with ipmi2.0. processor supports up to 225w tdp

Advertisement

Quick Links

HPM-SIEUA
AMD single 4th Generation EPYC 8004 Processor ATX
Server Board with IPMI2.0. Processor supports up to 225W
TDP
User's Manual
Ed – 30 August 2024
nd
2
Copyright Notice
Copyright © 2024 Avalue Technology Inc., ALL RIGHTS RESERVED.
Part No: E2047AAS001R

Advertisement

loading
Need help?

Need help?

Do you have a question about the HPM-SIEUA and is the answer not in the manual?

Questions and answers

Summary of Contents for Avalue Technology HPM-SIEUA

  • Page 1 HPM-SIEUA AMD single 4th Generation EPYC 8004 Processor ATX Server Board with IPMI2.0. Processor supports up to 225W User’s Manual Ed – 30 August 2024 Copyright Notice Copyright © 2024 Avalue Technology Inc., ALL RIGHTS RESERVED. Part No: E2047AAS001R...
  • Page 2 HPM-SIEUA User’s Manual Document Amendment History Revision Date Comment July 2024 Avalue Initial Release August 2024 Avalue Add 2.4 Processor Installation SOP 2 HPM-SIEUA User’s Manual...
  • Page 3 For detailed information, please always refer to the electronic user's manual. Copyright Notice © 2024 by Avalue Technology Inc. All rights are reserved. No parts of this manual may be copied, modified, or reproduced in any form or by any means for commercial use without the prior written permission of Avalue Technology Inc.
  • Page 4 ㆍDescription of your software (operating system, version, application software, etc.) ㆍA complete description of the problem ㆍThe exact wording of any error messages To receive the latest version of the user’s manual; please visit our Web site at: www.avalue.com 4 HPM-SIEUA User’s Manual...
  • Page 5 On the other hand, if the new product defect is resulting from incorrect configuration or erroneous use by the user instead of any problem of the hardware itself, the customer will also be requested to pay for relevant handling fees. HPM-SIEUA User’s Manual...
  • Page 6 Lacking detailed statement of fault steps also makes the problem hard to be identified, sometimes resulting in second-time repairs. 6 HPM-SIEUA User’s Manual...
  • Page 7 • Product has been altered or its label of the serial number has been torn off. • Product functionality issues resulting from improper use by the user, unauthorized dismantle or alteration, unfit operation environment, improper maintenance, accident HPM-SIEUA User’s Manual...
  • Page 8 If the customer demands an additional maintenance analysis report, a service fee of various level will be charged depending on the warranty status. In case the analysis result shows that the defect attributes to Avalue’s faulty design or process, the analysis fee will be exempted. 8 HPM-SIEUA User’s Manual...
  • Page 9 CPU, memory, HDD, SSD, storage devices; also replacements motherboards of systems. Please contact Avalue sales for details to evaluate the possibility of system upgrade service and obtain information of lead time and price. HPM-SIEUA User’s Manual...
  • Page 10 A NOTE provides additional information intended to avoid Note inconveniences during operation. Direct current. Alternating current Stand-by, Power on FCC Certification CE Certification Follow the national requirements for disposal of equipment. Stacking layer limit This side up 10 HPM-SIEUA User’s Manual...
  • Page 11 User’s Manual Fragile Packaging Beware of water damage, moisture-proof Carton recyclable Handle with care Follow operating instructions of consult instructions for use. HPM-SIEUA User’s Manual 11...
  • Page 12 EXPLOSION ou une fuite de liquide ou de gaz inflammable. - UNE BATTERIE soumise à une pression d'air extrêmement basse pouvant entraî ner une EXPLOSION ou une fuite de liquide ou de gaz inflammable. 12 HPM-SIEUA User’s Manual...
  • Page 13 HDD Backplane thermal Sensor (JHDD_SER1) ............... 40 2.3.24 CASE OPEN connector (JCASE_OPEN1) ................40 2.3.25 CPU PCIE HP SMB connector (JPEHPSMB1) ................. 41 2.3.26 SMBUS VR connector (JVR_PRG1) ..................41 2.3.27 ESPI connector (JESPI1) ......................42 HPM-SIEUA User’s Manual 13...
  • Page 14 PCI Subsystem Settings ......................68 4.6.2.10 USB Configuration ......................... 69 4.6.2.11 Network Stack Configuration ....................70 4.6.2.12 NVMe Configuration ......................70 4.6.2.13 SATA Configuration ....................... 71 4.6.3 Chipset............................71 4.6.3.1 North Bridge ........................... 72 4.6.3.1.1 Socket 0 Information ......................72 14 HPM-SIEUA User’s Manual...
  • Page 15 BMC network configuration ....................80 4.6.8.4 BMC User Settings ......................81 4.6.8.4.1 BMC Add User Details ......................81 4.6.8.4.2 BMC Delete User Details ......................82 4.6.8.4.3 BMC Change User Settings ..................... 82 5. Mechanical Drawing ....................83 HPM-SIEUA User’s Manual 15...
  • Page 16 électrostatique. Placez tous les composants électroniques sur une surface antistatique ou dans un sac antistatique quand ils ne sont pas dans le châssis. Risque d'explosion si la batterie est remplacée par un type incorrect. Jetez les piles usagées selon les instructions 16 HPM-SIEUA User’s Manual...
  • Page 17 Dispose of the battery in accordance with local regulations and instructions from your service provider. 1.2 Packing List Before installation, please ensure all the items listed in the following table are included in the package. Item Description Q’ty HPM-SIEUA motherboard I/O Shield HPM-SIEUA User’s Manual 17...
  • Page 18 We strongly recommend that you study this manual carefully before attempting to set up HPM-SIEUA or change the standard configurations. Whilst all the necessary information is available in this manual we would recommend that unless you are confident, you contact your supplier for guidance.
  • Page 19 (Connector : 1 x 1G Base-T RJ45 module jack over 2 x USB 3.1 Gen1 stacked receptacle) LAN 2 : 2.5GbE Ethernet port (Connector : 1 x 2.5G Base-T RJ45 module jack over 2 x USB 3.1 Gen1 stacked HPM-SIEUA User’s Manual 19...
  • Page 20 1 x Outlet sensor header (The onboard and external sensors will co-exist) Display 1 x VGA port (DB15 on edge I/O) Graphic Chipset AST2600 BMC controller Spec. & Resolution 1920x1200@60Hz 32bpp Ethernet LAN Chipset 1 x Intel I210AT 20 HPM-SIEUA User’s Manual...
  • Page 21 1 x Dual 10G Base-T Ethernet controller 1G LAN: 2.5G LAN: LED Indicator 10G LAN: Mechanical & Environmental 1 x Std. 24 pin ATX Connector Power Requirement 3 x 8 Pin SSI 12V Connectors Connector current rating information. HPM-SIEUA User’s Manual 21...
  • Page 22 2 Non-Operation mode 3 Test Frequency : 5-500Hz 4 Test Axis : X,Y and Z axis 5 30 min. per each axis 6 IEC 60068-2-64 Test:Fh Package Vibration Test: 1 Test PSD : 0.026G²/Hz , 2.16 Grms 22 HPM-SIEUA User’s Manual...
  • Page 23 Windows Server 2019 bare-metal support (KB5017379) & Hyper-V support (KB5018419) Windows Server IoT 2022. OS Information Ubuntu 20.04 LTS Ubuntu 22.04 LTS or later Red Hat Enterprise Linux (RHEL) 9.0 or later Note: Specifications are subject to change without notice. HPM-SIEUA User’s Manual 23...
  • Page 24 HPM-SIEUA User’s Manual 1.5 Architecture Overview—Block Diagram The following block diagram shows the architecture and main components of HPM-SIEUA. 24 HPM-SIEUA User’s Manual...
  • Page 25 User’s Manual 2. Hardware Configuration HPM-SIEUA User’s Manual 25...
  • Page 26 HPM-SIEUA User’s Manual 2.1 Product Overview 26 HPM-SIEUA User’s Manual...
  • Page 27 CPU fan connector 1-2 4 x 1 wafer, pitch 2.54mm Serial port 1 connector VGA_COM1 VGA connector JCOM2 Serial port 2 connector 5 x 2 wafer, pitch 2.00mm JCOM5 BMC_UART5 debug connector 4 x 1 header, pitch 2.54mm HPM-SIEUA User’s Manual 27...
  • Page 28 4 x 1 wafer, pitch 2.00mm JHDD_SER1 HDD Backplane thermal Sensor 5 x 1 wafer, pitch 2.00mm JPEHPSMB1 CPU PCIE HP SMB connector 5 x 1 header, pitch 2.00mm 2 x M.2 M-Key PCIe 5.0 x4 NVMe M2(NGFF)1/2 CPU1 CPU socket 28 HPM-SIEUA User’s Manual...
  • Page 29 User’s Manual 2.3 Setting Jumpers & Connectors 2.3.1 Boot UART5 setting (JPBOOT_UART5) Disable* Enable BOOT FROM UART5 * Default 2.3.2 SATA or PCIE select (JPSATASEL) PCIE* SATA * Default HPM-SIEUA User’s Manual 29...
  • Page 30 HPM-SIEUA User’s Manual 2.3.3 System fan connector 1 (SYS_FAN1) Signal +12V FAN_TACH1 SYS_PWM1 2.3.4 System fan connector 2 (SYS_FAN2) Signal +12V FAN_TACH2 SYS_PWM2 30 HPM-SIEUA User’s Manual...
  • Page 31 User’s Manual 2.3.5 System fan connector 3 (SYS_FAN3) Signal +12V FAN_TACH3 SYS_PWM3 2.3.6 System fan connector 4 (SYS_FAN4) Signal +12V FAN_TACH4 SYS_PWM4 HPM-SIEUA User’s Manual 31...
  • Page 32 HPM-SIEUA User’s Manual 2.3.7 System fan connector 5 (SYS_FAN5) Signal +12V FAN_TACH5 SYS_PWM5 2.3.8 System fan connector 6 (SYS_FAN6) Signal +12V FAN_TACH6 SYS_PWM6 32 HPM-SIEUA User’s Manual...
  • Page 33 User’s Manual 2.3.9 CPU fan connector 1 (CPU_FAN1) Signal +12V FAN_TACH0 CPU0_PWM 2.3.10 SPI connector (JSPI1) Signal PIN PIN Signal +1.8VSB SPI_CLK SPI_CS# SPI_MOSI SPI_MISO SPI_IO2 SPI_IO3 HPM-SIEUA User’s Manual 33...
  • Page 34 HPM-SIEUA User’s Manual 2.3.11 Serial port 2 connector (JCOM2) Signal PIN PIN Signal COM_RXD2 COM_DCD#2 COM_DTR#2 COM_TXD2 COM_DSR#2 COM_CTS#2 COM_RTS#2 COM_RI#2 2.3.12 BMC_UART5 debug connector (JCOM5) Signal UART5_TXD UART5_RXD +3.3VSB 34 HPM-SIEUA User’s Manual...
  • Page 35 User’s Manual 2.3.13 ATX 12V power connector 1 (ATX12V1) Signal Signal +12V +12V +12V +12V 2.3.14 ATX 12V power connector 2 (ATX12V2) Signal Signal +12V +12V +12V +12V HPM-SIEUA User’s Manual 35...
  • Page 36 HPM-SIEUA User’s Manual 2.3.15 ATX 12V power connector 3 (ATX12V3) Signal Signal +12V +12V +12V +12V 2.3.16 ATX power connector (ATXPWR1) Signal PIN PIN Signal +3.3V +3.3V -12V +3.3V PSON# PSU_PWRGD +V5SB +12V +12V +3.3V 36 HPM-SIEUA User’s Manual...
  • Page 37 2.3.17 Power supply PMBus connector (JPMBUS1) Signal SMB_PSU_SCL SMB_PSU_SDA SMB_PSU_ALERT# 2.3.18 USB3.2 Gen1 connector (JUSB1) Signal PIN PIN Signal FROONTUSB3_OC1_N 10 P0_USB_z_PP1 P0_USB_z_PP0 P0_USB_z_PN1 P0_USB_z_PN0 P0_USB3_z_TP1 P0_USB3_z_TP0 15 P0_USB3_z_TN1 P0_USB3_z_TN0 17 P0_USB3_z_RP1 P0_USB3_z_RP0 18 P0_USB3_z_RN1 P0_USB3_z_RN0 HPM-SIEUA User’s Manual 37...
  • Page 38 UID_LED# SBPWRLED_P UID_LED_P UID_BUTTON# LAN2-X_LED_P LAN2-X_LED# 2.3.20 Front Panel connector 2 (JFP2) Signal PIN PIN Signal +3.3VSB +3.3VSB UID_LED_P PWR_LED# UID_LED# HDD_LED_P STATUS_LED# LED_HDD# STATUS_LED_P PWRON_BUTTON# LAN1_LED_P LAN1_LED# RESET_BUTTON# SMBus_SDA SMBus_SCL UID_BUTTON# INTRUSION# LAN2-X_LED_P NMI_BUTTON# LAN2-X_LED# 38 HPM-SIEUA User’s Manual...
  • Page 39 User’s Manual 2.3.21 Inlet Thermal Sensor (JINLET_SER1) Signal +3.3VSB SMB_INLET_TEMPSENSOR_SDA SMB_INLET_TEMPSENSOR_SCL 2.3.22 Outlet Thermal Sensor (JOUTLET_SER1) Signal +3.3VSB SMB_OUTLET_TEMPSENSOR_SDA SMB_OUTLET_TEMPSENSOR_SCL HPM-SIEUA User’s Manual 39...
  • Page 40 HPM-SIEUA User’s Manual 2.3.23 HDD Backplane thermal Sensor (JHDD_SER1) Signal +3.3VSB SMB_HDBP_TEMPSENSOR_SDA SMB_HDBP_TEMPSENSOR_SCL SSD_LED_N 2.3.24 CASE OPEN connector (JCASE_OPEN1) Signal CHASSIS_INTRUSION 40 HPM-SIEUA User’s Manual...
  • Page 41 User’s Manual 2.3.25 CPU PCIE HP SMB connector (JPEHPSMB1) Signal SMB_CPUHP_SCL SMB_CPUHP_SDA SMB_CPUHP_ALERT# 2.3.26 SMBUS VR connector (JVR_PRG1) Signal SMB_VR_SDA SMB_VR_SCL HPM-SIEUA User’s Manual 41...
  • Page 42 HPM-SIEUA User’s Manual 2.3.27 ESPI connector (JESPI1) Signal PIN PIN Signal ESPI_ D0 +3.3VSB ESPI_ D1 PLTRST# ESPI_ D2 ESPI_CS# ESPI_ D3 ESPI_CLK ESPI_RESET# ESPI_ALERT# 42 HPM-SIEUA User’s Manual...
  • Page 43 Using the T20 screwdriver, begin with the screw labeled as "1" on the socket diagram. Next, remove the screw labeled as "2". C. Finally, remove the screw labeled as "3". →The Retention Frame will automatically pump up. (Figure 2) Figure 1 Figure 2 HPM-SIEUA User’s Manual 43...
  • Page 44 Remove the PnP Cap. A. Use thumb and forefinger to hold the removal tap of the PnP Cap. (Figure 5.1) B. Carefully remove the PnP Cap in a vertical motion only. (Figure 5.2) Figure 5.1 Figure 5.2 44 HPM-SIEUA User’s Manual...
  • Page 45 ➢ Ensure the carrier frame makes a slight 'click' when engaging with the rail frame. Failure to secure it may result in damage to the socket cap and contacts. Finger grip Figure 6 Finger grip Figure 7 Figure 7.1 HPM-SIEUA User’s Manual 45...
  • Page 46 Stiffener Frame. Slightly press down fully, it will get stuck and won’t bounce back. (Figure 8) B. Press Retention Frame and then tighten the captive screw with T20 screwdriver. (Figure 9) Note: ➢ Tighten the screws completely in the order of 1→2→3 Figure 8 Figure 9 46 HPM-SIEUA User’s Manual...
  • Page 47 Figure 11. Apply downward pressure for about 1–2 seconds, then stop tightening. ➢ Repeat the process by tightening the screws complete down in numerical order to complete the module assembly. Figure 10 Figure 11 HPM-SIEUA User’s Manual 47...
  • Page 48 Enter to find all the relevant software, utilities, and documentation. Note: Installation procedures and screen shots in this section are for your reference and may not be exactly the same as shown on your screen. 48 HPM-SIEUA User’s Manual...
  • Page 49 Note: The installation procedures and screen shots in this section are based on Windows Server operation system. Step 3. Setup Successful. Step1. Click Install. Step 4. Click Next. Step 2. Click Install. Step 5. Click Next. HPM-SIEUA User’s Manual 49...
  • Page 50 HPM-SIEUA User’s Manual Step 6. Click Next. Step 7. Click Install. Step 8. Setup completed. 50 HPM-SIEUA User’s Manual...
  • Page 51 Note: The installation procedures and screen shots in this section are based on Windows Server operation system. Step 3. Click Next. Step 1. Click Next to continue installation. Step 4. Setup completed. Step 2. Click Next. HPM-SIEUA User’s Manual 51...
  • Page 52 All drivers can be found on the Avalue Official Website: www.avalue.com. Note: The installation procedures and screen shots in this section are based on Windows Server operation system. Step 1. Click OK to continue installation. Step 2. Setup completed. 52 HPM-SIEUA User’s Manual...
  • Page 53 User’s Manual 4.BIOS Setup HPM-SIEUA User’s Manual 53...
  • Page 54 If the message disappears before you respond and you still wish to enter Setup, restart the system to try again by turning it OFF then ON or pressing the "RESET" button on the system case. You may also restart by simultaneously pressing <Ctrl>, <Alt>, and <Delete> keys. 54 HPM-SIEUA User’s Manual...
  • Page 55 Note: Some of the navigation keys differ from one screen to another. • To Display a Sub Menu Use the arrow keys to move the cursor to the sub menu you want. Then press <Enter>. A “➢” pointer marks all sub menus. HPM-SIEUA User’s Manual 55...
  • Page 56 BIOS Vendor and your systems manufacturer to provide the absolute maximum performance and reliability. Even a seemingly small change to the chipset setup has the potential for causing you to use the override. 56 HPM-SIEUA User’s Manual...
  • Page 57 Note: The BIOS setup screens shown in this chapter are for reference purposes only, and may not exactly match what you see on your screen. Visit the Avalue website (www.avalue.com) to download the latest product and BIOS information. HPM-SIEUA User’s Manual 57...
  • Page 58 4.6.2.1 Trusted Computing Item Options Description Enables or Disables BIOS support for security device. Disable, Security Device Support O.S. will not show Security Device. TCG EFI protocol Enable[Default] and INT1A interface will not be available. 58 HPM-SIEUA User’s Manual...
  • Page 59 User’s Manual 4.6.2.2 PSP Firmware Versions 4.6.2.3 ACPI Settings Item Options Description Enable ACPI Auto Disabled[Default] Enables or Disables BIOS ACPI Auto Configuration. Configuration Enabled HPM-SIEUA User’s Manual 59...
  • Page 60 HPM-SIEUA User’s Manual 4.6.2.4 AMD CBS 4.6.2.4.1 CPU Common Options Item Option Description Disabled Controls IO based C-state generation and DF Global C-state Control Enabled C-states. Auto[Default], Disabled AVX512 Enabled Enable/Disable AVX512. Auto[Default], 60 HPM-SIEUA User’s Manual...
  • Page 61 Option Description Manual Auto = Use the fused TDP Manual = User TDP Control Auto[Default], can set customized TDP. Manual Auto = Use the fused PPT Manual = User PPT Control Auto[Default], can set customized PPT. HPM-SIEUA User’s Manual 61...
  • Page 62 Manual = User can set custom Auto[Default], performance determinism settings. 4.6.2.5 AMD PBS 4.6.2.5.1 CPU PCIe Port Bifurcation Item Option Description Auto[Default], Switch the PCIe x8 port bifurcation configuration. Slot 1 x4x4 The options include Auto, x4x4 and x8. 62 HPM-SIEUA User’s Manual...
  • Page 63 Slot 6 The options include Auto, x4x4x4x4, x4x4x8, x8x4x4 x8x4x4, x8x8 and x16. x8x8 Auto[Default], Switch the PCIe x8 port bifurcation configuration. Slot 7 x4x4 The options include Auto, x4x4 and x8. 4.6.2.6 AST2600 Super IO Configuration HPM-SIEUA User’s Manual 63...
  • Page 64 Set Parameters of Serial Port 1 (COMA). Serial Port 2 Configuration Set Parameters of Serial Port 2 (COMB). 4.6.2.6.1 Serial Port 1 Configuration Item Option Description Enabled[Default], Serial Port Enable or Disable Serial Port (COM). Disabled 4.6.2.6.2 Serial Port 2 Configuration 64 HPM-SIEUA User’s Manual...
  • Page 65 Serial Port Enable or Disable Serial Port (COM). Disabled 4.6.2.7 Serial Port Console Redirection Item Options Description Disabled[Default], Console Redirection Console Redirection Enable or Disable. Enabled Disabled[Default], Console Redirection EMS Console Redirection Enable or Disable. Enabled HPM-SIEUA User’s Manual 65...
  • Page 66 Console Redirection is disabled before booting to Always Enable[Default] legacy OS. When Always Enable is selected, then Redirect After POST BootLoader Legacy Console Redirection is enabled for legacy OS. Default setting for this option is set to Always Enable. 66 HPM-SIEUA User’s Manual...
  • Page 67 User’s Manual 4.6.2.8 CPU Configuration Item Options Description Disabled SVM Mode Enable/disable CPU Virtualization Enabled[Default], 4.6.2.8.1 Node 0 Information HPM-SIEUA User’s Manual 67...
  • Page 68 Globally Enables or Disables Hot-Plug support for the entire System has Hot-Plug capable Disabled Hot-Plug Support Slots and this option set to Enabled, it Enabled[Default], provides a Setup screen for selecting PCI resource padding for Hot-Plug. 68 HPM-SIEUA User’s Manual...
  • Page 69 Mass storage device emulation type. ‘AUTO’ Auto[Default] Floppy enumerates devices according to their media Mass Storage Devices Forced FDD format. Optical drives are emulated as ‘CDROM’, drives with no media will be Hard Disk CD-ROM emulated according to a drive type. HPM-SIEUA User’s Manual 69...
  • Page 70 HPM-SIEUA User’s Manual 4.6.2.11 Network Stack Configuration Item Option Description Enabled Network stack Enable/Disable UEFI Network Stack. Disabled[Default] 4.6.2.12 NVMe Configuration 70 HPM-SIEUA User’s Manual...
  • Page 71 User’s Manual 4.6.2.13 SATA Configuration 4.6.3 Chipset Item Option Description Off[Default] PCIe Compliance Mode PCIe Link Compliance Mode. HPM-SIEUA User’s Manual 71...
  • Page 72 HPM-SIEUA User’s Manual 4.6.3.1 North Bridge 4.6.3.1.1 Socket 0 Information 72 HPM-SIEUA User’s Manual...
  • Page 73 User’s Manual 4.6.4 Security ⚫ Administrator Password Set setup Administrator Password ⚫ User Password Set User Password 4.6.4.1 Secure Boot HPM-SIEUA User’s Manual 73...
  • Page 74 Boot Option #1 Set the system boot order. Enables or disables boot with initialization of a Disabled[Default] Fast Boot minimal set of devices required to launch active Enabled boot option. Has no effect for BBS boot options. 74 HPM-SIEUA User’s Manual...
  • Page 75 Reset the system after saving the changes. 4.6.6.2 Discard Changes and Reset Any changes made to BIOS settings during this session of the BIOS setup program are discarded. The setup program then exits and reboots the controller. HPM-SIEUA User’s Manual 75...
  • Page 76 This option restores all BIOS settings to the user defaults. This option is useful for restoring previously preserved custom BIOS setup configurations. 4.6.6.6 Launch EFI Shell from filesystem device Attempts to Launch EFI Shell application (Shellx64.efi) from one of the available filesystem devices. 4.6.7 Firmware Update 76 HPM-SIEUA User’s Manual...
  • Page 77 User’s Manual HPM-SIEUA User’s Manual 77...
  • Page 78 Wait For BMC response for specified time out. BMC starts at the same time when BIOS starts Enabled Wait For BMC Disabled[Default] during AC power ON. It takes around 30 seconds to initialize Host to BMC interfaces. 78 HPM-SIEUA User’s Manual...
  • Page 79 Choose options for reactions to a full SEL. Delete Oldest Record[Default] Disabled Both Disable the logging of EFI Status Codes or log Log EFI Status Codes Error code[Default] only error code or only progress code or both. Progress code HPM-SIEUA User’s Manual 79...
  • Page 80 Option Description Yes, On every reset[Default] Erase Log Erase Log Options. Clear Log[Default] When log is full Select the action to be taken when log is full. Do not log any more 4.6.8.3 BMC network configuration 80 HPM-SIEUA User’s Manual...
  • Page 81 Select to configure LAN channel parameters Unspecified[Default] statically or dynamically(by BIOS or BMC). Configuration Address source Static Unspecified option will not modify any BMC DynamicBmcDhcp network parameters during BIOS phase. 4.6.8.4 BMC User Settings 4.6.8.4.1 BMC Add User Details HPM-SIEUA User’s Manual 81...
  • Page 82 HPM-SIEUA User’s Manual Item Description User Name Enter BMC User Name. 4.6.8.4.2 BMC Delete User Details Item Description User Name Enter BMC User Name. 4.6.8.4.3 BMC Change User Settings Item Description User Name Enter BMC User Name. 82 HPM-SIEUA User’s Manual...
  • Page 83 User’s Manual 5. Mechanical Drawing HPM-SIEUA User’s Manual 83...
  • Page 84 HPM-SIEUA User’s Manual Unit: mm 84 HPM-SIEUA User’s Manual...