Download Print this page

Proton PSU-BOB i4 Instruction Manual

Power supply and breakout box for sl/slr i4 and sl/slr mini i4 speed and length gauges

Advertisement

Quick Links

Instruction Manual
PSU-BOB i4
Power Supply and Breakout Box
For SL/SLR i4 and SL/SLR mini i4 Speed and
Length Gauges
Issue 1e
8 April 2022
Proton Products Co. Ltd.
10 Aylesbury End
Beaconsfield
Buckinghamshire HP9 1LW
England
www.protonproducts.com
Page 1 of 17
Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)

Advertisement

loading
Need help?

Need help?

Do you have a question about the PSU-BOB i4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Proton PSU-BOB i4

  • Page 1 For SL/SLR i4 and SL/SLR mini i4 Speed and Length Gauges Issue 1e 8 April 2022 Proton Products Co. Ltd. 10 Aylesbury End Beaconsfield Buckinghamshire HP9 1LW England www.protonproducts.com Page 1 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 2 ......17 ONTACT DETAILS FOR ENQUIRIES SALES AND SERVICE ............................17 EB SITE ......................... 17 NQUIRIES AND SALES ..........................17 ERVICE ENQUIRIES ............17 ANUAL FEEDBACK AND COPYRIGHT Page 2 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 3 Description Part number Power supply and “INTERFACE” port breakout box for use PSU-BOB i4 with Proton Products SL/SLR i4 and SL/SLR mini i4 speed 00060MC050 and length gauge. The manufacturer of the above named equipment is: Proton Products International Limited...
  • Page 4 NTRODUCTION The PSU-BOB i4 is an optional accessory for the Proton Products SL / SLR (mini) i4 speed and length gauge. It provides the following functions: • Connects to a SL / SLR (mini) i4 gauge via the DB44 “INTERFACE” connector.
  • Page 5 IMENSIONAL RAWING Page 5 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 6 7. Connect the INTERFACE port to the SL INTERFACE port using a DB44M-toDB44F cable. 8. Connect the AC power cable. 9. Enable laser output using the laser enable key switch. Page 6 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 7 To re-install the lid, follow the reverse procedure. ECHANICAL MOUNTING The unit may be mounted to a flat surface using the 4 indicated mounting holes (mounting hardware not included): Page 7 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 8 • Do not rely on any mounting bolts to provide a reliable earth path. • All earth wires should be kept as short as practical. Page 8 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 9 Ensure that all cable screens are correctly clamped and connected to their connectors and metal connector shells at any end-user equipment. • The PSU-BOB cable glands are fitted with metal fingers which must contact the cable screens for correct EMC protection. Page 9 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 10 RS-422 compliant Inverted pulse differential pair outputs. output 1 Pulse output 2 RS-422 compliant Inverted pulse differential pair outputs. output 2 RS-422 compliant Pulse output 3 differential pair outputs. Page 10 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 11 This terminal is connected via the key- Laser enable key- switch to DGND. A Key-switch KEY SW switch removable jumper connects this terminal to the /LSR_EN terminal. Page 11 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 12 • For frequent control of the laser output (such as disabling the laser output when a safety guard is opened), please use the shutter enable (“SHUT /EN”) signal. Page 12 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 13 If the shutter needs to be controlled from a remote location (such as to block laser emission when a safety guard is opened), then the “SHUT /EN”-to-“DGND” shorting link may be disconnected from the screw terminals and substituted with a remotely-mounted switch. Page 13 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 14 ONNECTION TO A GAUGE Connect the “INTERFACE” port of the PSU-BOB I4 to the “INTERFACE” port of the SL I4 gauge using a DB44M-to-DB44F cable: PSU-BOB I4 SL mini I4 gauge Connector type: DB44 male (plug) Connector type: DB44 female (socket) Suitable DB44M-to-DB44F cables may be ordered from Proton Products in the following lengths: DB44M-to-DB44F PSU-BOB I4 “INTERFACE”...
  • Page 15 Unit is powered off Power off The unit has no power switch; it may be powered off by switching off or disconnecting the mains power supply to the unit. Page 15 of 17 Proton Products PSU-BOB I4 Instruction Manual (Issue 1e)
  • Page 16 PROFI A Shield Note: the I-BUS port on the PSU-BOB i4 is only for PROFIBUS communication. RJ45 port (10/100BASE-T) is used for Modbus TCP/IP, together with Profinet or Ethernet/IP when enabled. Both protocols will be available on the same RJ45. If 2 separate Ethernet connections are needed, a managed switch is necessary.
  • Page 17 Proton Products is not responsible for consequential or incidental damage related to the provision or use of the information contained in this manual. • The information contained in this manual is the property of Proton Products and may not be circulated or distributed to third parties. •...