Moisture Analyzer
Operation Manual
Please read and adhere to all recommendations in this manual to ensure the best experience and to maintain
your Analyzer in good working order. The manual is for SMA-100 moisture analyzer.
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SMA-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stalwart SMA-100

  • Page 1 Moisture Analyzer Operation Manual Please read and adhere to all recommendations in this manual to ensure the best experience and to maintain your Analyzer in good working order. The manual is for SMA-100 moisture analyzer.
  • Page 2 1. Introduction 1.1. Safety Precautions For safe and dependable operation of this Analyzer, please comply with the following safety precautions: Use the Analyzer exclusively for determination of moisture in samples. Improper operation of the Analyzer can endanger personnel and cause property damage. If the Analyzer is used in a manner not specified in this manual, the protection provided may be impaired.
  • Page 3 • Power Input: 200VAC-240VAC, 3A, 50Hz • Voltage fluctuation: 220 ± 10% • Power load: 250W (maximum power during heating) • Protection: Protection from dust and dampness 1.3. Specifications: Model SMA-10A SMA-50A-1 SMA-50A-5 SMA-100 Weighing Range 100g Readability 10mg Repeatability (3g samples) 0.5% 0.2% 0.3% 0.3%...
  • Page 4 2. Installation 2.1. Selecting the Location • Operate the Analyzer on a firm, level surface. • Select a location that is safe and with adequate ventilation. Fire, corrosive or toxic fumes and other hazards associated with the test samples will require specially prepared locations. •...
  • Page 5 Export: Insert a USB flash drive, select the file to be exported. Temp Cal: The temperature has been calibrated before leaving factory. If there is no professional equipment, please do not calibrate temperature by yourself. The temperature calibration is for external temperature calibration. There is a temperature difference between the temperature in the heating chamber and the temperature of the temperature probe.
  • Page 6 5.2. Sample Weight The weight of the sample affects the test time and the repeatability of the results. The maximum weight of the sample is 50g. The heavier the sample is, the more water is evaporated and the longer the test time is. In general, it is recommended that the sample weight is 3g-10g, which can get faster results, but there is a lack of measurement accuracy.
  • Page 7 No stable Weighing instability Waiting for stability Range over Overweight Reduce weighing objects No plate Not put the pan on the pan support Put the pan on the pan support Testing in progress, no other Wait for the end of the test, and then press It's working operations can be performed.