Download Print this page

Advertisement

Quick Links

MMI6050/8050 Series
MMI6050/8050 Series....................................................................................................................................1
1.0 Environmental Considerations ............................................................................................................1
2.0 Mounting Instructions..........................................................................................................................1
3.0 Power Connections...............................................................................................................................3
4.0 Communications Connections..............................................................................................................6
5.0 Dip Switch Settings..............................................................................................................................7
6.0 MMI Indicator Lights...........................................................................................................................8
7.0 Other Hardware Considerations...........................................................................................................8
8.0 Trouble Shooting..................................................................................................................................8
9.0 Specifications.......................................................................................................................................9
1.0 Environmental Considerations
See Specifications for environmental constraints.
Location
The MMI Series is designed for use in a factory environment. It is designed to
operate from 32 to 113 °F (0 to 45 °C) temperatures, as found in most industrial
environments. It may not be suitable for use in certain outdoor applications. Please
consult the factory for advised usage in outdoor applications.
NEMA
The MMI Series front bezel is NEMA 4 rated. When installed properly in a NEMA 4
Rating
panel, the NEMA 4 rating of the panel is not compromised. This means that fluids
do not enter the panel through the MMI series panel during wash downs.
Do not operate the unit in areas subject to explosion hazards due to flammable
gases, vapors or dusts.
The unit should not be installed where fast temperature variations and/or high
humidity are present. This causes condensation of water in the device.
Avoid installing units in environments where severe mechanical vibration or shocks
are present.
Vibration endurance: 10 to 25 Hz (X,Y,Z direction 2G 30 minutes)
2.0 Mounting Instructions
2.1 LOCATION CONSIDERATIONS
Care should be taken when locating equipment behind the unit to ensure that AC power wiring,
PLC output modules, contactors, starters and relays, and any other source of electrical
interference are located away from the back of the unit.
Particular note should be taken to the position of variable speed drives and switching power
supplies. Their input and load cables should be screened to a central star earth point.
MMI6050/8050
Installation Instruction
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the MMI6050 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for KEP MMI6050 Series

  • Page 1 MMI6050/8050 Series MMI6050/8050 Installation Instruction MMI6050/8050 Series............................1 1.0 Environmental Considerations ......................1 2.0 Mounting Instructions..........................1 3.0 Power Connections..........................3 4.0 Communications Connections......................6 5.0 Dip Switch Settings..........................7 6.0 MMI Indicator Lights...........................8 7.0 Other Hardware Considerations......................8 8.0 Trouble Shooting..........................8 9.0 Specifications............................9 1.0 Environmental Considerations See Specifications for environmental constraints.
  • Page 2 2.2 Making a NEMA-4 Mounting Panel The unit can be mounted into panels with a depth of 4”(105mm). It is recommended Details that the unit be mounted on the front panel of a steel enclosure, through an appropriate opening*. Allow a clearance of 1”(25mm) around the sides of the unit for mounting hardware.
  • Page 3 3.0 Power Connections Make sure that all local and national electrical standards are met when the installing the unit. Contact your local authorities to determine which codes apply. 3.1 POWER REQUIREMENTS The MMI can be powered by DC power only. The specified voltage range is Power +23 to 25 Volts DC.
  • Page 4 To make an MMI comply with EMC directives, and to reduce susceptibility to electrical interference, a separate #14 AWG ground wire should be taken to Requirements the chassis ground terminal of the power connector. This ground connection should be run directly to the central star earth connection point (as recommended in most Installation Instructions).
  • Page 5 ICS 3-304.81 Safety Recommendations: Consideration should be given to the use of an emergency stop function, which is independent of the programmable controller. Where the operator is exposed to the machinery, such as in loading or unloading a machine tool, or where the machine cycles automatically, consideration should be given to the use of an electromechanical override or other redundant means, independent of the programmable controller, for starting and interrupting the cycle.
  • Page 6 D-SUB Male connector. Connection This port can be attached to a Computer via a Standard USB to Mini-USB cable provided with the unit. (KEP P/N: MT6_PC) Port Activation This port is activated automatically by the PC during: Download and Upload activities.
  • Page 7 4.2 CONNECTION TO A CONTROLLER Cable Different cables are required for various devices. See EasyBuilder 8000 Help Requirements Controller Reference Section for cable details. Pin assignment of the 9 Pin, Male, D-SUB PLC[RS232] & PLC [RS-485] Port Pin Designations Symbol COM 1 [RS485] COM 1 [RS485] COM 1 [RS232]...
  • Page 8 6.0 MMI Indicator Lights PWR – Indicates if power has been applied to the unit. If this indicator fails to light, check power, check polarity of wiring and check fusing. If all conditions are correct, contact the factory for help. CPU –...
  • Page 9 Use our toll free number to contact KEP if persistent problems are encountered. Telephone: 1-800-631-2165. If the product must be returned for any reason, be sure to call KEP and get a Return Goods Authorization (RGA) number first. Units should be returned in their original packaging container, otherwise, any suitable rigid container can be used as a substitute.
  • Page 10 1024x768 resolution VGA, and one available USB or Ethernet port. We hope you will be pleased with our products. If you have any questions concerning our warranty, repair, modification or returned goods process, please contact your local KEP distributor or the KEP Customer Service Department.

This manual is also suitable for:

Mmi8050 series