Download Print this page
Lenovo ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Manual
Lenovo ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Manual

Lenovo ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Manual

Advertisement

Quick Links

ThinkSystem Micro DataCenter 6U 800mm
Deep Rack Cabinet
User Guide
Machine Type: 7D3F and 7D3G

Advertisement

loading
Need help?

Need help?

Do you have a question about the ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet and is the answer not in the manual?

Questions and answers

Summary of Contents for Lenovo ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet

  • Page 1 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide Machine Type: 7D3F and 7D3G...
  • Page 2 First Edition (June 2020) © Copyright Lenovo 2020. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services Administration (GSA) contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No.
  • Page 3 Index ....59 Install the DPI universal rack power distribution unit....© Copyright Lenovo 2020...
  • Page 4 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 5 Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright Lenovo 2020...
  • Page 6 • Always install stabilizer brackets on the rack cabinet. • Always install the heaviest devices in the bottom of the rack cabinet. • Always install servers and optional devices starting from the bottom of the rack cabinet. R003 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 7 2. Remove the signal cables from the connectors. 4. Attach signal cables to other devices. 3. Remove all cables from the devices. 5. Connect power cords to their sources. 6. Turn ON all the power sources. © Copyright Lenovo 2020...
  • Page 8 Do not connect a power cord from a device that is installed in one rack cabinet to a power device that is installed in a different rack cabinet. R009 CAUTION: ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 9 Pack the rack cabinet in the original packaging material, or equivalent. Also, lower the leveling pads to raise the casters off the pallet and bolt the rack cabinet to the pallet. © Copyright Lenovo 2020...
  • Page 10 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 11 Chapter 1. Introduction ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet is a 6U cabinet designed for Micro DataCenter servers. Figure 1. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet The cabinet comes with a limited warranty. For details about the warranty, see: https://support.lenovo.com/us/en/solutions/ht503310...
  • Page 12 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 13 Chapter 2. Specifications See this section for information about ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet. Dimension and weight Dimension • Length: 800 mm (31.5 inch) • Width: – Without the wheeled tray: 345 mm (13.58 inch) – With the wheeled tray: 512.5 mm (20.18 inch) •...
  • Page 14 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 15 Chapter 3. Parts Listing Figure 2. Rack cabinet components Table 1. Rack cabinet components Rack cabinet frame Shipping bracket Wheeled trays Removable and reversible door Removable side panel Hardware box (see “Hardware box” on page Removable side panel © Copyright Lenovo 2020...
  • Page 16 Table 2. Components in the hardware box 20 M6 screws One socket wrench 16 flange nuts One spud socket wrench 20 G-type cage nuts 15 cable ties One combination wrench Two bolt-down brackets ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 17 WARNING: Failure to follow these instructions could result in equipment damage, severe injuries, or death. Before moving the rack cabinet, complete the following steps: 1. Unlock and open both doors by pulling up the handle and turning it clockwise. © Copyright Lenovo 2020...
  • Page 18 Figure 4. Opening the door 2. Remove the four shipping brackets that secure the cabinet to the pallet. Figure 5. Removing shipping brackets Two options are available when moving the cabinet: ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 19 Casters S037 CAUTION: The weight of this part or unit is more than 55 kg (121.2 lb). It takes specially trained persons, a lifting device, or both to safely lift this part or unit. Complete the following steps to move the cabinet to the designated site: Step 1.
  • Page 20 • Make sure that more than two people are handling the cabinet while sliding it down from the ramp board. • Do not stand in the path of the cabinet. Crane lifter ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 21 Attention - Drop hazard. Complete the following steps to lift and move the cabinet to the designated site: Step 1. Remove the four plugs from the four corners on the top of the cabinet frame. Figure 9. Lifting the rack cabinet Step 2.
  • Page 22 Figure 12. Tightening the nut 2. To secure the cabinet to the ground, you can install the bolt-down brackets that is included in the hardware box (see “Hardware box” on page ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 23 Figure 13. Installing the bolt-down brackets Chapter 4 Moving the rack cabinet...
  • Page 24 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 25 See this section to learn how to connect ground cable in the rack cabinet. The following grounding pins close to door frame bottom are available for grounding cable connection. Grounding cable from the cabinet frame This cable is required for grounding. © Copyright Lenovo 2020...
  • Page 26 Figure 15. Grounding cable from the cabinet frame Grounding cable from the cabinet door This is an optional grounding cable. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 27 Figure 16. Grounding cable from the cabinet door Grounding cable from the side panel This is an optional grounding cable. Chapter 5 Managing cables...
  • Page 28 Figure 17. Grounding cable from the side panel ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 29 Note: When installed vertically into this cabinet, the server can be installed with server top facing either right or left. In this section, however, it is illustrated with the top of server facing right as an example. © Copyright Lenovo 2020...
  • Page 30 ① Pull the inner rail outward until the release latch becomes visible. ② Press on the release latch. ③ Remove the inner rail from the outer rail. Step 2. Install the inner rails to the enclosure. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 31 Figure 19. Installing the inner rails to the enclosure ① Align the mounting holes in the inner rail with the corresponding rail mounting pins on the side of the enclosure. ② Push the inner rail as shown until the mounting pins on the enclosure lock into place with the inner rail.
  • Page 32 ③ Push the rail into the EIA flange until the pins protrude through into the corresponding holes in the rack. ④ The bracket will lock into place as illustrated. Step 7. Install the front mounting bracket of the right outer rail to the lower mounting flange. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 33 Figure 23. Installing the front mounting bracket to the EIA flange Note: Make sure the rail stays horizontal. ① Open the front bracket and align the front end of the outer rail to the EIA flange. ② Pull the outer rail into the EIA flange until the pins are inserted into the corresponding holes. ③...
  • Page 34 Note: Make sure the top of the enclosure is facing right. ① Lift and align the enclosure to the slide rails. Position the enclosure as shown, and slide it into the rack. ② Press the release latches. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 35 ③ Push the enclosure all the way into the rack until it clicks into locked position. Step 12. (Optional) Open the rack release latches and tighten the screws to firmly secure the rail before moving or placing the rack cabinet in a vibration-prone area. Figure 27.
  • Page 36 In this section, however, it is illustrated with the top of server facing left as an example. P P r r o o c c e e d d u u r r e e Step 1. Remove the inner rails. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 37 Figure 29. Removing the inner rails ① Pull the inner rail outward until the release latch becomes visible. ② Press on the release latch. ③ Remove the inner rail from the outer rail. Step 2. Install the inner rails to the server. Chapter 6 Installing optional kits...
  • Page 38 Note: Make sure the stamp “Front” always faces toward the front when assembling the inner rail to the server. Step 3. Rotate the server counter-clockwise so that the left side is facing down. Figure 31. Rotating SR250 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 39 Step 4. Install the rear mounting bracket of the right outer rail to the lower EIA flange. Figure 32. Installing the rear mounting bracket to the EIA flange ① Align the rear pins on the outer rails to the EIA flange. ②...
  • Page 40 ③ Push the enclosure all the way into the rack until it clicks into locked position. Step 9. (Optional) Open the rack release latches and tighten the screws to firmly secure the rail before moving or placing the rack cabinet in a vibration-prone area. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 41 Figure 36. Securing the server Rack release latches Front screw Remove the server from the rack Figure 37. Removing SR250 ① Disconnect all the cables that are connected to the server, and slide the server out until it stops. ② Press the release latches to disengage the inner rails. ③...
  • Page 42 • When moving or replacing the cabinet after installation, contact a qualified installer specified by Lenovo service. Installation or movement of the product must be carried out by a skilled professional. If an unqualified person moves and installs the product, it may cause safety risks.
  • Page 43 Figure 38. Mounting bolt location on the wall Step 2. Remove the six screws that secure the two wheeled trays. Chapter 6 Installing optional kits...
  • Page 44 Removing the four screws on the top cover; then, secure the upper wall mounting bracket above the lower bracket with two screws, and install two eyebolts to the key shape holes on the upper bracket. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 45 Figure 41. Securing the lower bracket Step 8. Connect the two eyebolts and two keyholes in the upper wall mounting bracket to the hook of a crane lifter, and make sure the cord length allows an angle more than 75˚. Step 9.
  • Page 46 Step 13. Lift the cabinet with two people, and align the key-shaped holes on the upper bracket to the two top nails; then, carefully lower the cabinet and make sure the bottom nails fit in the notches in the lower bracket. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 47 Figure 43. Installing the cabinet to the wall Install the DPI universal rack power distribution unit Follow the instructions in this section to install the DPI universal rack power distribution unit. A A b b o o u u t t t t h h i i s s t t a a s s k k See the following table to identify the components that come with the rail kit.
  • Page 48 Secure the power distribution unit to one side of the horizontal mounting plate with two screws. Figure 44. Securing the power distribution unit Step 2. Install the bracket to the rack. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 49 Installing switches See this section to learn how to install switches into ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet. This rack cabinet supports the following switches. See the corresponding links for installation instructions. • https://systemx.lenovofiles.com/help/topic/com.lenovo.thinksystem.ne0152t.doc/ts_ne0152t.html • https://systemx.lenovofiles.com/help/topic/com.lenovo.thinksystem.ne1032t.doc/ts_ne1032t.html • https://systemx.lenovofiles.com/help/topic/com.lenovo.thinksystem.ne2572.doc/ts_ne2572.html •...
  • Page 50 See this section to learn how to install uninterruptible power systems (UPS). Following the instructions in the following link to do removal, installation, or to update compatible software for 5P1500R-L (120V) and 5P1550GR-L (230V). https://www.eaton.com/us/en-us/catalog/backup-power-ups-surge-it-power-distribution/eaton-5p- ups.resources.html ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 51 Pivot the top of the panel away from the cabinet frame to remove it. Install the side panels Complete the following steps to install the side panels. P P r r o o c c e e d d u u r r e e © Copyright Lenovo 2020...
  • Page 52 Note: For safety, this task must be done by two people. 1. If necessary, insert the key and turn it clockwise to unlock the door. 2. Pull the lower end of the handle up and clockwise; then, open the door. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 53 Figure 49. Opening the door P P r r o o c c e e d d u u r r e e Step 1. Pull up and hold both of the hinge shafts to disengage the door from the cabinet frame; then, remove the door.
  • Page 54 P P r r o o c c e e d d u u r r e e Step 1. Align the door to the frame hinges, and push the shafts in to secure the door to the frame. Figure 51. Installing the door ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 55 A A f f t t e e r r t t h h i i s s t t a a s s k k i i s s c c o o m m p p l l e e t t e e d d 1.
  • Page 56 P P r r o o c c e e d d u u r r e e Step 1. Pull up and hold both of the hinge shafts to disengage the door from the cabinet frame; then, remove the door. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 57 Figure 54. Removing the door Step 2. Remove the screws that secure the hinges to the cabinet frame. Step 3. Rotate both hinges 180 degree, switch the top and bottom hinges; then, install them to the opposite side of the frame. Figure 55.
  • Page 58 Install the device to the equivalent location on the opposite side on the cabinet frame. Figure 57. Installing the door position monitor device Remove the device from the door, and install it to the equivalent location on the opposite side of the door. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 59 Figure 58. Removing and installing the door position monitor device Step 5. Remove the screws that secure the handle to the door; then, rotate the door 180 degree while keeping the handle in the original orientation, and secure the handle to the door with screws. Figure 59.
  • Page 60 1. Close the cabinet door, and turn the door handle counterclockwise to secure it. Figure 61. Closing the cabinet door 2. If necessary, insert the key and turn it counterclockwise to lock the door. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 61 See this section for replacement of the door position monitor device. Note: This component is a Third Party Option parts. Not with standing anything to the contrary, third party options are excluded from Lenovo Statement of Limited Warranty. See https://support.lenovo.com/us/en/ for details.
  • Page 62 P P r r o o c c e e d d u u r r e e Step 1. Remove the two screws that secure the door position monitor device to the cabinet frame. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 63 Figure 64. Removing door position monitor device Install the door position monitor device P P r r o o c c e e d d u u r r e e Step 1. Secure the device to the cabinet frame with two screws. Figure 65.
  • Page 64 Figure 66. Closing the cabinet door 2. If necessary, insert the key and turn it counterclockwise to lock the door. ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 65 Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about Lenovo products, you will find a wide variety of sources available from Lenovo to assist you. On the World Wide Web, up-to-date information about Lenovo systems, optional devices, services, and support are available at: http://datacentersupport.lenovo.com...
  • Page 66 Gathering information needed to call Support If you believe that you require warranty service for your Lenovo product, the service technicians will be able to assist you more efficiently if you prepare before you call. You can also see http:// for more information about your product warranty.
  • Page 67 Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead.
  • Page 68 Trademarks Lenovo, the Lenovo logo, Micro DataCenter, ThinkSystem, Flex System, System x, NeXtScale System, and X Architecture are trademarks of Lenovo in the United States, other countries, or both. Intel and Intel Xeon are trademarks of Intel Corporation in the United States, other countries, or both.
  • Page 69 ThinkSystem Micro DataCenter iv, 1 ThinkSystem Micro DataCenter 6U 800 mm Deep Rack Cabinet 3, 5, 7, 19, 31, 37, 39–41, 45, 52–53 managing cables trademarks Micro DataCenter moving wall mount kit notices © Copyright Lenovo 2020...
  • Page 70 ThinkSystem Micro DataCenter 6U 800mm Deep Rack Cabinet User Guide...
  • Page 72 Part Number: SP47A59024 Printed in China (1P) P/N: SP47A59024 *1PSP47A59024*...

This manual is also suitable for:

7d3f7d3g