AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT • USER’S MANUAL • MANUAL UTILIZATORULUI • BENUTZERHANDBUCH MODELS: EMPVI-24WFI/EMPVO-24...
Page 4
Keep this manual where the user can easily nd it. · Do not use means to accelerate the defrosting process or to clean, other than those · recommended by the manufacturer. The appliance must be stored in a room without continuously operating ignition sources (for ·...
Page 6
Parts and Functions Indoor Unit Remote controller Operation mode indicator Outdoor Unit...
Page 7
Operation LIGHT/RESET/ Clock set EXTRA FUNCTION RESET CONFIRM CANCEL EXTRA FUNCTION...
Page 8
Operation AUTO,COOL,HEAT,DRY,FAN Operation starts In DRY mode, the unit will initiate the dehumidifica- tion process. Cool air will be blow during this mode. The fan speed depends on the difference between the room temperature and the set temperature. MODE circulated...
Page 9
Operation I FEEL Operation HEALTH Operation HEALTH The Ionizer generates ions in the air and together with the UVC function, they help to provide better air quality by killing bacteria and speeding up the dust sediment in the room. Attention:...
Page 11
Operation HEALTH AIRFLOW Operation TURBO/QUIET Operation TURBO/QUIET HEALTH AIRFLOW under direclty HEALTH AIRFLOW Attention:...
Page 12
Operation 3-Level-Eco Operation SWING Operation 4. In COOL mode, the running frequency can be adjusted between 85%, 70% or 50%. In HEAT mode, the running frequency can be adjusted between 90%, 80% or 50%.
Page 13
Operation ECO SENSOR Operation TIMER Operation ECOSENSOR Remote controller: “TIMER ON”will flash. TIMER OFF CONFIRM CANCEL CONFIRM CANCEL NOTE: After replacing batteries or a power failure happens, time set- ting should be reset. According to the time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Page 14
Operation ON/OFF operation and test operation ON/OFF Operation: Test operation: Loading of the battery...
Page 15
This appliance contains a UV-C lamp. Refer to the maintenance instructions prior to opening the appliance. Eye or skin irritation may result from direct exposure to the UV-C lamp, do not look and/or touch the UV-C lamp directly. Be certain that there is no power supply to the unit before removing UV-C barriers with the ultraviolet radiation hazard symbol should not be removed.
Page 16
56°C Sterilization The 56°C Sterilization function can only be activated through the mobile application Inventor Control. When 56°C Sterilization function is activated, the air conditioner will operate as below: 1st Stage: The air conditioner will start with the Self Clean function in order to remove the dirt.
Page 17
Make sure that the router is close to the air conditioner for unhindered pairing prossess and wireless operation. Step 1: Download and install the “Inventor Control” application from the Google Play Store or IOS App Store. Step 2: Select “Register” to create a new Step 3: To add the device, select “My...
Page 18
Step 6: Press “Go to Connect” to enter your mobile Network and enter the conditioner to the power supply and turn it on. Set the “U-AC-XXXX”. Return to Inventor Control once connected. to proceed. The pairing air conditioner to Cooling process may take some Mode, Low Fan Speed and time.
Page 20
Liquid pipe Φ 6.35x0.8mm FOR 09K 12K Gas pipe Φ 9.52x0.8mm Liquid pipe Φ 6.35x0.8mm FOR 18K Gas pipe Φ 12.7x0.8mm Liquid pipe Φ 9.52x0.8mm FOR 24K Gas pipe Φ 15.88x1.0mm Attention must be paid to the rising up of drain hose mor e than 15 cm mor e than 10 cm...
Page 22
C od e A n alyze an d diag n o s e T ro ub le d e sc ription in d ica tio n F a u lty c o n ne cto r c o n ne ction ; F a u lty th e rm isto r;...
Page 26
All the pictures in the manual are for explanatory purposes only. The actual shape of the unit you The company may not be held responsible for any misprinted information. The design and the without any prior notice. Please consult with the manufacturer at +30 211 300 3300 or with the Local Distributor for further details.
Page 32
AUTO, COOL, HEAT, DRY Στη λειτουργία DRY, η μονάδα θα ξεκινήσει τη διαδικασία αφύγρανσης. Κατά τη διάρκεια αυτής της λειτουργίας απο τη μονάδα θα εξέλθει δροσερός αέρας. Η ταχύτητα του ανεμιστήρα εξαρτάται από τη διαφορά μεταξύ της θερμοκρασίας του χώρου και...
Page 36
SWING 3 LEVEL ECO Λειτουργία Η λειτουργία 3-Level-Eco εξασφαλίζει τη μέγιστη δυνατή εξοικονόμηση ενέργειας, επιτρέποντας να ρυθμίζετε τη συχνότητα λειτουργίας του συμπιέστη. Πατήστε το πλήκτρο ECO μια φορά για να επιλέξετε το επίπεδο L1. Πατήστε ξανά το πλήκτροECO για να εισέλθετε...
Page 37
ECO SENSOR TIMER TIMER TIMER ON προτιμίσεις TIMER TIMER TIMER OFF TIMER που δεν έχει ανιχνεύσει κίνηση στο δωμάτιο.
Page 52
RED Declaration of Conformity (DoC) Unique identification of this DoC: 20210308001 We, INVENTOR A.G. ELECTRIC APPLIANCES S.A. declare under our sole responsibility that the product: product name: Wi-Fi Module trade name: Inventor type or model: WFM-H20 relevant supplementary information: N.A.
Page 53
AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT V:1.0.032024 INVENTOR A.G. S.A.