The DAKOTA stove is an economical and highly efficient heating appliance designed for heating industrial spaces. In addition, the stove is well suited for permanent space heating and for spaces that are used temporarily and intermittently. CONTENTS 1. INTRODUCTION 2. TECHNICAL DATA 3.
1445* 2 000 708* 269,08 1 000 6-10 1344 INTRODUCTION This installation and operating manual relates to a heating system for a furnace intended for heating industrial premises. The DAKOTA stove is an economical and highly efficient solid fuel heating appliance.
Page 4
purpose and it depends on many factors, for example: heat losses through the surrounding construction; ceiling height; ventilation; firewood moisture, etc. Pull regulator Lock Lounge link Cleaning Secondary chamber hatches Deflector Door handle Oven Injector door Primary chamber Blowing Manhole Convection tubes Figure 1.
The ignition flue has a blow-by timer (boost regulator) that can be used to adjust the intensity of fuel combustion. The post-combustion mode of the CO released from the fuel shall be set by means of a flue gas regulator (gas regulator) in each case on a case-by-case experimental basis, depending on the design of the flue.
Page 6
on a brick base, as shown in Figure 2. The underside of the oven door, which is composed of combustible and flammable materials, shall be protected by a metal sheet 700 x 700 mm, placed long side down along the length of the oven.
Page 7
in an acidic environment, such an anchor quickly becomes unusable. For this NOTE! For non-insulated (stainless) metal chimney flue assemblies, insert the reason, the corrosion resistance of the chimney is important. A suitable material top pipe into the bottom pipe (Figure 2). is acid-resistant stainless steel, which ensures the bell's durability.
To prevent the chimney from becoming clogged with soot and condensate This will provide rain protection for the roof and attic. and to make chimney cleaning more convenient, a T-shaped fitting (Figure 3) The height of the flue above the roof shall be as follows: with a removable cap (funnel) should be installed immediately after the –...
Within 2-3 minutes after the fuel has been properly ignited, close the oven Do not burn any type of plastic, rubber, etc. in the stove, as this will release door and cover it with the damper and only then close the damper. This is toxic gases and pollute the environment.
Do not use the stove while: MANUFACTURER'S GUARANTEE – leave the stove unattended or under the supervision of children; The manufacturer guarantees the conformity of the oven with the TU U 27.5-23764970-026:2022 provided that the consumer complies with the requirements –...
Page 11
Reasons Method of elimination Rikked. External manifestations GUARANTEE MAP Stove does not heat, Insufficient height of the chimney. Install the chimney according to point 3 smoke, no draft of Table 1. Lack of thermal insulation on the outer parts of the chimney. Isolate bellows compartments outside the room.
Need help?
Do you have a question about the Dakota Series and is the answer not in the manual?
Questions and answers