Download Print this page
Star FL3X SFP 1000BASE-T1 Instructions For Use Manual

Star FL3X SFP 1000BASE-T1 Instructions For Use Manual

Sfp transceiver for automotive ethernet

Advertisement

Quick Links

FL3X SFP 1000BASE-T1
Instructions for Use

Advertisement

loading
Need help?

Need help?

Do you have a question about the FL3X SFP 1000BASE-T1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Star FL3X SFP 1000BASE-T1

  • Page 1 FL3X SFP 1000BASE-T1 Instructions for Use...
  • Page 2 Therefore, the product is only allowed to be used in the sense of the product use case described herein. STAR ELECTRONICS GmbH & Co. KG makes no warranty express or implied, as to this document or the information content, materials or products for any particular purpose, nor does STAR ELECTRONICS GmbH & Co.
  • Page 3  EN 55011  EN 61326-1 The FL3X SFP 1000BASE-T1 is designed, intended and authorized for industrial use only. Using the product in domestic environment may lead to electromagnetic disturbances. This product is compliant with the European Community Directive 2011/65/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS).
  • Page 4 Intended Use ............................5 Used Pictograms ..........................6 Safety and Handling Instructions ......................7 Product Description ..........................8 FL3X SFP 1000BASE-T1 at a glance ..................... 8 Accessory Parts ........................... 8 Technical Data ............................9 Electrical Characteristics ........................9 Physical Characteristics ........................9 Environmental Conditions ........................
  • Page 5 The use of the product by non-professionals is not permitted and strictly forbidden! Intended Use The FL3X SFP 1000BASE-T1 is a testing equipment. It was developed to test the communication behavior of automotive bus systems and Ethernet together with Electronics Control Units and sensors in a fully controlled testing and/or laboratory environment.
  • Page 6 WARNING The FL3X SFP 1000BASE-T1 is NOT designed, intended, or authorized any may NOT be used for or in connection with the following purposes and/or devices: - use as part of medical systems...
  • Page 7 FL3X SFP 1000BASE-T1 has to be handled as described herein. Changes or modifications of the FL3X SFP 1000BASE-T1 are not allowed for safety and warranty reasons! STAR ELECTRONICS GmbH & Co. KG is not liable for any damages arising from non-observance of the product information.
  • Page 8 Fully compatible to any STAR COOPERATION networking products and many more SFP cards and devices (not compatible with all SFP+ connectors) Accessory Parts For further information about accessories for the FL3X SFP 1000BASE-T1 see chapter 7.2 Accessory Parts. NOTICE Use only accessory parts from STAR ELECTRONICS GmbH & Co. KG listed in chapter 7.2 Accessory Parts to ensure proper function and for warranty reasons!
  • Page 9 Figure 1: Block diagram from the FL3X SFP 1000BASE-T1 DIP Switch (Master/Slave and 100/1000BASE-T1) The FL3X SFP 1000BASE-T1 has two DIP switches for setting the Baud rate and the master/slave mode. To change the setting insert a small fine part and change carefully the switch position.
  • Page 10 1000BASE-T1 bus minus signal Table 4: Connector assignment for SPE (2-wire ethernet) The FL3X SFP 1000BASE-T1 has one LED for showing Link and Activity, see the following figure. The LED is behind the golden colored clamp on the bottom side of PCB.
  • Page 11 The following table shows the LED status. Status Description No or wrong connection Link established Blinking Data transmission Table 5: LED status Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 11 of 22...
  • Page 12 Ignore Device Number = 0x00 General writing and reading via I2C is explained in the next chapter. The STAR tunnel can be accessed via the address 0x80. This can be used to configure the PHY manually or to use register commands. For an operation, the register Device number, Register_Address_MSB, Register_Address_LSB and Operation Status must be written in the STAR Tunnel.
  • Page 13 C Access to the Addresses 0x80 and 0xA0. The access commands are for example with the address 0xA0. 4.2.2.1 Read (Current Address) Read current Address Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 13 of 22...
  • Page 14 Second Step: Read the data from the Register Address + W/R Register 4.2.2.3 Sequential read Sequential read current Address Address + W/R Data n Data n+1 Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 14 of 22...
  • Page 15 Second Step: Sequential Read the data from the Register Address + W/R Data n Data n+1 4.2.2.5 Write (Current Address) Write current Address Address + W/R Register data Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 15 of 22...
  • Page 16 1 0 0 0 0 0 0 0 0 X X X X X X X X 0 X X X X X X X X 0 X X X X X X X X 0 Address + W/R Register Data n Data n+1 Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 16 of 22...
  • Page 17 Shipping, Maintenance and Disposal Dispose off properly per regulations of the country where end-of-life occurs. Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 17 of 22...
  • Page 18 Troubleshooting This chapter contains some frequently asked questions about the FL3X SFP 1000BASE-T1. Effect Solution Effect Solution Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 18 of 22...
  • Page 19 2 pole SPE male to 2 pole H-MTD male BusCable 250 2SPE2m waterproof, 3-00343Q01 2HMTDmw OABR 2,5m Please contact Customer specific parts STAR ELECTRONICS GmbH & Co. KG Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 19 of 22...
  • Page 20 Table 3: DIP switch function ..........................10 Table 4: Connector assignment for SPE (2-wire ethernet) ..................10 Table 5: LED status ............................11 Table 6: STAR tunnel register ..........................12 Table 7: operation status register ........................13 Table 8: PIC register 0x0000 ..........................13 Table 9: PIC register 0x0001 ..........................
  • Page 21 8.2.3 List of Figures Figure 1: Block diagram from the FL3X SFP 1000BASE-T1 ..................9 Figure 2: Position from the DIP switch ........................ 10 Figure 3: SPE connector ............................. 10 Figure 4: Position of LED ............................ 11 Created by STAR ELECTRONICS GmbH & Co. KG...
  • Page 22 STAR ELECTRONICS GmbH & Co. KG A Company of the STAR COOPERATION Group Jahnstraße 86 73037 Goeppingen Germany Phone: +49 (0) 7031 6288-5656 sales-ee@star-cooperation.com www.flex-product.com Created by STAR ELECTRONICS GmbH & Co. KG Date created 2024-10-17 Date modified 2024-10-22 Page 22 of 22...

This manual is also suitable for:

3-01110a01