New Rcom Pro 20 USER'S MANUAL
New Rcom Pro 20 USER'S MANUAL
1. Safety Cautions
Electrical hazards
Do not use a damaged
Do not pull the cord when
taking out the power cord,
power cord or loose
and keep wet hands away
outlet.
from connecting plug.
Risk of electric shock or fire.
Risk of electric shock or fire.
Setting Cautions
Do not install in dusty or
Do not install under the
dirty environment.
direct sunlight.
Risk of damage or fire within
Risk of fire or interference with
the incubator.
the incubation process.
Do not cover the
Install away from heat
ventilating opening.
sources.
Inner temperature can rise,
Risk of damage to the incubator
case and interference with
interrupting incubation.
the incubation process.
Do not disassemble or
Please ensure that no
modify the incubator in
small objects get into
any way.
the holes on the incubator.
Risk if electric shock or fire.
Risk of electric shock or fire.
Cleaning Cautions
Do not spray cleanser
Clean the incubator by a
directly on the incubator
soft cloth with a neutral
surface.
detergent.
2. Identification of Parts
Vents for air circulation
For circulating warm air
View Window
Air inlet vent
For a clear view of
For inlet of air
the incubation process.
from outside
( duplicated View Window )
Digital Control Center
See description of
the function and operation.
Locking Button
3. Basic Components
Main Body-1
Water Cap
View Window
Small Egg Tray
Universal Tray
(Option)
4. How to Assemble
View Window
Insert the power cord
in the socket at the back
standard egg tray
of the main body.
Main Body-1
Egg turning Plate
Lock the three locking
Main Body-2
buttons at the front and rear
of the incubator.
PX-20D, PX-20DUSB(Professional)
Be careful the details below when you use.
Never pull the plug out of
Do not twist or crush
Do not insert multiple
the outlet during the
electric cord.
connecting plugs in an
incubation period.
outlet.
Risk of fire or electrical overload.
Incubation will be interrupted.
Risk of electric shock or fire.
Be careful the details below when you use.
Do not install in moist or
Do not install in excessively
Do not use any other
cold or hot conditions,
non-standard parts
humid environment.
cigarette smoke, etc.
except those provided.
Risk of fire or electric shock.
Risk of interference with
Risk of damage or hatching
the incubation process.
failure.
Ensure that the incubator is
Do not turn the incubator
Do not install where
installed on a stable surface
children or other people
upside down.
away from edges.
can touch with easy.
Risk of damage to incubator
Water will pour out of the incubator,
Risk of knocking the incubator
and eggs and user from
and view window can be dropped
or accidental interference with
accidental knocks or drops.
or damaged.
the controls.
If the incubator sounds
Clean the incubator
If the incubator requires
strange or emits smoke
thoroughly before storing.
repair disconnect from the
contact your service
power supply and please
center.
contact to your service center.
Risk of electric shock or fire.
Be sure to disconnect the electric cord
from the outlet before cleaning.
For special cleaning of
Brush away dust on the
Do not use chemicals like wax,
plug with a dry cloth.
benzene, alcohol, thinner,
inner part per year, contact
to the service center.
aromatic, or lubricant, etc.
Power Connecting
For connecting
power cord.
To facilitate water top-up
for the humidity control.
Main Body-1
Main Body-2
Main Body-2
Egg turning Plate
User's Manual
Standard Egg Tray
Large Egg Tray
USB Cable
PC SOFTWARE
< USB MODEL >
< USB MODEL >
Program CD Included
5. How to Replace Fuse
▶ When the machine failed to
power on even if you plugged in,
remove the fixing piece like
the picture by screwdriver.
▶ You can find assembled PCB
when open the cover.
Remove faulty fuse with screwdriver.
▶ Replace with new fuse.
( 250V 2.0A Ø5*20mm )
6. Before use
Digital Incubator
▶ Insert the electric cord in the connecting socket at the back of the Main body and
www.R-com.co.kr
put the power cord into the outlet. The display will come on.
There can be some odor the first time you use the incubator, that is normal.
There can be some odor the first time you use the incubator, that is normal.
▶ Open the watercap and fill the hole with clean water. And, refill water after 5 min.
The styrofoam ball floats on and blocks the hole when full.
(Humidity goes down temporarily, in case you refill water under incubation period.)
You should stop to fill in the water as soon as the Styrofoam ball floats on.
The ball will block the hole when full.
After filling up with water, never shake or turn over the main body of the incubator.
Check the water level
Check the water level every three days and refill fully on incubation period.
The light for water top-up can remain for a while after you filled up.
The light for water top-up can remain for a while after you filled up.
▶ Place your eggs and cover the view window.
Be careful to close the view window completely; if not, the temperature will fail
to go up.
The egg to incubate must be a fertilized egg.
The egg to incubate must be a fertilized egg.
You can turn off humidification function when you don't fill water with your incubation
or when you need low humidity incubation under 30%.
(Water supplement alarm will turn off with this function.
Refer to "How to turn OFF humidification function.")
7. Operation Part
Menu Button
- Select Reptiles
- Incubation Termination
Select Button
- Select Auto/Manual,
- Pass to next stage
Function Button
- Other function display
- Return to previous stage
8. Display Part Explanation
ICON
Chicken
1
2
3
4
Egg Tray
5
Small, Standard,
or Large egg tray
6
according to egg size.
< USB MODEL >
Universal Tray
9. SET UP(Other Functions)
(Sold Seperately)
Water Cap
T.CAL
Temperature
Calibration
H.CAL
Humidity
Calibration
A LA RM
Abnomal
High Alarm
A LA RM
Abnomal
Power Cord
low Alarm
Uni t
Li ght
Sound
ALL RESET
Factory setting
Info
10. Easy Function Operation
Automatic Mode
Incubation
Other(Manual) Mode
Incubation
How to change Setting under Incubation
(MANUAL)
Incubation
Termination
Incubator Initialization
(Factory Setting)
℃ ↔ ℉
How to change
How to turn off
Humidification Function
(In case of low humidity incubation)
every three days
and refill
fully
on incubation period.
New
D i g i t a l I n c u b a t o r
MENU
Chicken
MANUAL
SHIFT
37.5
1h
55
90˚
SET UP
BACK
DIGITAL INCUBATOR
Egg Turning Interval Indication (per hour)
Egg Turning Angle Indication
NAME AND FUNCTION
ICON
Species of Birds
Heater Stop Display
7
Heater Operation Display
Humidification Stop Display
Bird Icon Display
Humidification Operation Display
8
Power Failure Notification
Egg Turning Indication
9
37.5
Manual Egg Turning Stop Indication
Automatic Egg Turning Stop Indication
Incubation Termination
10
PC Connecting
11
Alarm
WARNING
Be sure to read CAUTIONS. ( Calibration available after 5 Sec. )
Fatal Damage
with Incorrect Calibration !
Temp. calibration limits : -9.9℃ ~ +9.9℃
WARNING
Be sure to read CAUTIONS. ( Calibration available after 5 Sec.)
Fatal Damage
with Incorrect Calibration !
Hi gh
Alarm sounds when incubator temp. is higher than setting value
because of room temp. change or heating system disorder
T emp
* Setting Range : 0.0℃~5.0℃ (Default Setting : 2.0℃)
Hi Er r
Low
Alarm sounds when incubator temp. is lower than setting value
because of room temp. change or heating system disorder
T emp
* Setting Range : 0.0℃~5.0℃ (Default Setting : -3.0℃)
LoEr r
Selecting Centigrade (
o
C) and Fahrenheit (
* Default Value : Centigrade (
o
C)
LCD Backlight management setting
* Always On : Always BackLight On
* Event On
: 20 Sec. ON with Key input
ON/OFF Setting for Melody, other alarms
* Default Value : ON
It returns to factory setting when you change the initial setting at discretion.
ALL RESET
Basic information of Incubator (versoin Indication)
REFER TO "HOW TO START INCUBATION" FOR MORE INFORMATION.
Select
MANUAL
the Species of Bird
UP
Select
MENU
ENTER
the Species of Bird
DOWN
Once: Temp. Setting
Four times: Humidity Setting
MANUAL
Seven times:
Egg Turning Angle Setting
Nine times: Egg Turning Interval Setting
Screen
System finish
on Incubation
MENU
Are you sure?
UP
"All Reset"
SET UP
BACK
DOWN
UP
℃
SET UP
ENTER
BACK
℉
DOWN
Screen
DOWN
MANUAL
on Incubation
4 times
UNDER 30%
Ver E 3.1
Up Button
- Temp. & Humidity UP
- Setting Value Change
UP
Down Button
DOWN
- Temp. & Humidity DOWN
- Setting Value Change
ENTER
Input Button
- Enter input value,
Pass to next stage
- Setting Value Check
NAME AND FUNCTION
**Ch oos e a k i nd**
* Chicken ①
* Duck ②
* Quail ③
* Pheasant ④
* Peafowl ⑤
* Goose ⑥
* wildgoose ⑦
* G-Pheasant ⑧
* Turkey ⑨
* Others Birds ⑩
FAN Operation Display
Current Temperature Display
Temperature Abnormal Display
Current Humidity Display
40
OFF
Humidification function OFF
Water Supplement
Humidity Abnormal
o
F)
* Always Off : Always BackLight Off
* Default Value : Always On
ENTER
2 Sec.
Temp. Setting
Humid. Setting
ENTER
Egg Turning Angle Setting
Egg Turning Interval Setting(Incubation day)
UP
ENTER
DOWN
UP
Select YES
ENTER
DOWN
ENTER
ENTER
UP
℃↔℉
ENTER
DOWN
"OFF"
ENTER
Need help?
Do you have a question about the Pro 20 and is the answer not in the manual?
Questions and answers