Parts list

  1. 27mm wearable breast pump x2
  2. 0.94inch/24mm flange insert x2
  3. Bra adjustment strap x2
  4. Type-c cable x2
  5. Small brush x2
  6. Storage bag x2
  7. User manual x1
  8. Breastfeeding manual x1

Wearable breast pump

Wearable breast pump

Assembling

  1. Put the silicone diaphragm into the milk collector, and press it with your hands to make the edges fasten tightly to ensure a perfect seal.
    Assembling - Step 1
  2. Put the silicone shield into the breast milk collector and press it with your hands to make the edges tightly fastened. Make sure to install it in the correct direction.
    Assembling - Step 2
  3. Install the pump motor on the breast milk collector to ensure that it fits perfectly with the breast milk collector.
    Assembling - Step 3
  4. Connect the type c charging cable to charge the battery.
    Assembling - Step 4

warningNote:

  1. This product has a built-in Ii-lon battery. When the battery indicator lights red, we recommend that you use a certified 5V- -1A adapter to charge the pump motor as soon as possible.
  2. The power adapter is a common standard accessory on the market. This product is not provided and can be purchased separately if necessary. Power adapter specifications: 5V1A.
  3. The duration of pumping should be no more than 20 minutes.
  4. Check all parts for malfunction or damage. Parts may need to be rep aced in time.

Cleaning and sterilizing

  1. For the first time and before each use, you must disassemble, wash and sterilize all the breast pump parts that come into contact with breast milk.
  2. After use, please immediate y disassemble and clean al parts in contact with breasts and breast milk (membrane, milk bottle, duckbill valve, shield) to avoid breast milk residue or bacterial growth; It is recommended to use drinking water or detergent for cleaning (water temperature should not exceed 100 ºC,exceed ing it will damage the part sand lead to deformation of the parts).

Control panel

Control panel

  1. Expression Mode
  2. Stimulation Mode
  3. Auto Mode
  4. Increase Power
  5. Power Button/Mode Selection Button
  6. Strength Display
  7. Battery Display
  8. Time Consuming Display
  9. Time/Minute
  10. Reduce Power

warningOperation cautions

  1. These components do not come into your breast milk. You can wipe those parts clean with a soft cloth.
  2. Take care when cleaning the valve and the silicone diaphragm. If it gets damaged, your breast pump will not function properly.
  3. To clean the valve, rub it gently between your fingers in warm soapy water. Do not insert objects as this may cause damage.

Display description

  1. Press the silicone funnel firmly against the breast, leave no gaps and make sure your nipples are centered. Keep it upright. Be careful not to distort the position of the product and the chest, otherwise, the breast pump will not have suction.
    Display description - Step 1
  2. Lightly press the power button to start the breast pump, and the screen display will light up.
    Display description - Step 2
  3. Short press the "" power button to switch to the Stimulation Mode "" There are 12 levels in this mode. You can press the"" and "" button to select the suction power that makes you comfortable.
    Display description - Step 3
  4. Short press the "" power button to switch the Expression Mode "". There are 12 levels in this mode. You can press the "" and "" buttons to select the suction power that makes you comfortable.
    Display description - Step 4
  5. Short press the power button "" to switch to the Auto Mode "". There are 12 levels in this mode. Levels 1-6 are Stimulation Mode "", and levels 7-12 are Expression Mode "". The range of automatic up shift is 1-9 levels and, the interval between up shifts is 20 seconds. 10-12levels need to be adjusted manually. During the up shifting process, you can select the suction power that makes you comfortable by pressing the "" and "" buttons.
    Display description - Step 5
  6. Long press the power button "" to turn off the breast pump.
    Display description - Step 6
  7. After pumping, press the power button to turn off the breast pump, lean forward slightly, and then careful y remove the breast pump from the breast. If there is a small amount of breast milk remaining at the silicone shield, you can tilt the breast pump slightly to pour the remaining breast milk from the silicone shield.
    Display description - Step 7

Tips:

  1. This model has a built-in memory function, when you turn on the machine again, the machine automatically enters and up shifts to the working mode and suction level you used last time.
  2. The breast pump will automatically stop after 50 minutes of work.
  3. When you wear the breast pump, relax and sit in a comfortable chair, leaning forward slightly (use the cushion to support your back). In this way, the silicone shield of the breast pump can be slightly inclined upward, which facilitates the flow of breast milk into the milk collector and reduces the residual breast milk in the silicone shield.

Instructions for duckbill valve installation

Instructions for duckbill valve installation
Insert the raised part of the duckbill valve into the round hole at the bottom of the suction bowl groove of the bra.

Instructions for bra adjusting buckle

Adjusting the length of bra straps, makes pumping more comfortable. One end of the bra adjustment buckle hung on the inside buckle of nursing bra. Adjust the length of the bra buckle according to your preference.
Instructions for bra adjusting buckle

Instructions for pouring milk

After you finish pumping, please remove the breast pump from the breast. Keep the breast pump upright and remove the motor part, hold the milk collector to pour the breast milk into a bottle, and make sure the milk collector gap of the breast cup is aligned with the mouth of the bottle to prevent breast milk spilled.
Instructions for pouring milk - Step 1
Instructions for pouring milk - Step 2

Storing your breast milk

  • Breast milk storage
    1. Only store breast milk collected from sterilized breast pumps.
    2. The sucked milk should be placed in a clean and sterilized milk storage bag or a milk bottle with a seal, and immediate y placed in the refrigerator to refrigerate or freeze.
  • Breast milk cold storage
    1. Do not refreeze breast milk twice.
    2. Do not mix fresh breast milk with frozen breast milk.
    3. Be sure to throw away any remaining breast milk after feeding.
    4. The pumped milk can be refrigerated in the refrigerator for 48 hours, or frozen in the freezer for 5 months (Do not store breast milk in the door of the refrigerator or freezer The milk bottle or milk storage bag can be affixed with a label clearly marking the milking date and time.
  • Thawing breast milk
    Place the frozen breast milk in the refrigerator overnight to thaw. If you're in a hurry, the fastest way to defrost breast milk is to put it in a bowl of warm water. The thawed breast milk must be consumed within 24 hours.
  • Heating breast milk
    1. Place the baby bottle with breast milk upright in a bowl of warm water or in a food heater to warm breast milk safely and quickly.
    2. Keep in mind! Before feeding your baby, be sure to check the temperature of breast milk.
    3. Do not use a microwave oven to heat breast milk as this may destroy important nutrients and antibodies.
    4. Uneven heating may ead to partial overheating of the milk and cause burns.
    5. Do not heat the baby bottle with breast milk in boiling water to avoid rupturing or cracking.

FAQ

Why does the breast pump leak milk?

Possible reasons

  1. You may be in an incorrect milking position.
    Solution: Please choose the most comfortable seated position for milking.
  2. The parts of the pump were not disassembled during cleaning, resulting in the deformation of the product.
    Solution: Please disassemble all parts while cleaning the breast pump. If the parts are deformed during use, please replace the accessories timely.
  3. The duckbill valve and milk collector are in poor condition.
    If they are damaged or aged, the milk cannot go down into the bottle and will run out of the bra's place.
    Solution: Please check if the product is in good condition before using it, and replace it with new accessories in time.

Why does the breast pump suck little breast milk?

The design principle of the breast pump is to imitate the action of the baby sucks, stimulating the breast to secrete milk, and achieve the purpose of expressing breast milk; If you feel that the effect of the breast pump is not obvious and hope to pump more breast milk, you can place warm, wet washcloths on your breasts for 5 minutes in advance to activate your chest, and then use the automatic gear or massage gear for 5 minutes, and then slowly adjust the gear to find out the appropriate frequency for yourself.

Can a breast pump with a lithium battery be taken on a plane?
Yes, although our breast pump has a built-in lithium battery, the capacity of it meets the flight safety requirements.

Why does the breast pump have a plastic smell?

Please don't worry, it's normal for the product to have a slight smell. Our breast pumps are made of enviromental-friendly BPA-free PP and silicone materials. We recommend that you open the bag and box and put them aside for a day after receiving the goods. f you need it urgently, we suggest you wash it with white vinegar or baking soda, and there will be no odor.

What should mothers pay attention to while breastfeeding?

  1. Before using the breast pump, we recommend that you use a hot towel for about 3 minutes to encourage the breasts to open up and produce milk so that the pumping speed will be faster.
  2. When you use the breast pump, the gear of it should not be too large, you just need to adjust to the gear you feel comfortable with. It is recommended that mothers fully open the breasts with a massage or automatic block, and then increase the suction.
  3. GeneraIly speaking, one breast can be pumped within 8 minutes, we recommend that the maximum use time should not exceed 20 minutes.

Why do I feel the suction of my breast pump is too low?
Please check whether all parts are installed correctly and whether the breast pump is adjusted to the appropriate gear.

Product parameters

Model S21
Product name Wearable Breast Pump
Material Food Grade Silicone, ABS
Product size 7.08*5.70*3.14inch/180*145*80mm
Adapter Output 5V/1A
Lithium Battery Voltage 3.7V
Battery Capacity 1000 mAh, 1.85Wh
Duration 30 Minutes

After-Sales Service

If you reach us for any product problem, damaged product or product defects, we are responsible for our Wearable Breast Pumps.
support@mommed.com
www.mommed.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download MOMMED S21 Manual

Advertisement

Need help?

Need help?

Do you have a question about the S21 and is the answer not in the manual?

Questions and answers

Table of Contents