  • Page 3: Wall Bracket Mounting

    WALL OPENINGS LAYOUT A. UTILITIES SUPPLY LINES 4 [102 mm] SINK & SHROUD OUTLINE 1 1/2 WASTE LOCATION GFI OUTLET LOCATION 20 1/2 [521 mm] 22 1/2 [572 mm] 20 1/4 [515 mm] 6 1/2 [165 mm] 3 1/16 [78 mm] FINISHED FLOOR B.
  • Page 4 31422 0622...
  • Page 5 31422 0622...
  • Page 6 31422 0622...
  • Page 7 31422 0622...
  • Page 8 31422 0622...
  • Page 9: Water Inlet

    SIGNAL LINE CONNECTOR WATER OUTLET WATER INLET 31422 0622...
  • Page 10 Connect G 1/2" water Connect the signal Connect water outlet supply hose to the line to the control hose from spout to water inlet. box. control box. Secure with clamp. 7.1 Connect the transformer to the control box and plug the transformer into a GFI wall outlet. 7.2 Put in 4 x AA batteries into battery box.
  • Page 11 Set sensor range (if necessary) To set the sensor range, hold down the red reset button on the right hand side of the control box for 3 seconds. Place a hand in front of the sensor at a distance where you want the water flow to trigger.
  • Page 12 31422 0622...
  • Page 13: Troubleshooting

    TROUBLESHOOTING GENERAL CLEANING Use only soap, water and a soft cloth for cleaning. Clean sensor lens with non-abrasive materials only. 31422 0622...