Page 2
Warranty HONGYUV hereby represents and warrants all Products manufactured by HONGYUV and sold here under to be free from defects in workmanship or material during a period of twenty-four (24) months from the date of delivery save for products for which a special warranty is given.
About measurement sampling rate: The ultrasonic probes sample hundreds of times per second, and process those raw data as wind speed and wind direction output every second. Hongyuv Technology Co.,Ltd Tel: +86 28 87702755 Fax: +86 28 85593421 Email: info@hongyuv.com...
1 pcs User Manual 1 pcs PACKING NOTICE By keeping HY-WDC2E well positioned in ex-work package when it’s being transferred to protect it from any potential damage. 7.APPERANCE SKETCH 7.1 Metal Shell North marker”△” on the top help you align unit toward to north It’s also zero direction of the anemometer.
Page 6
Raised oblong north marker should be pointed toward to north Gap on bottom south marker should be pointed to south Hongyuv Technology Co.,Ltd Tel: +86 28 87702755 Fax: +86 28 85593421 Email: info@hongyuv.com Website: www.hongyuv.com...
Page 7
Please point out that requirement when order it. Note: 1.Default output is RS485. 2.Final definition of cable wiring should be referred to sticker on cable. Hongyuv Technology Co.,Ltd Tel: +86 28 87702755 Fax: +86 28 85593421 Email: info@hongyuv.com Website: www.hongyuv.com...
Page 8
4F 4E 46 49 47 55 52 45 20 4D 4F 44 45 0D 0A in HEX). So far, the communication test is finished, device is proven to be communicated successfully. Hongyuv Technology Co.,Ltd Tel: +86 28 87702755 Fax: +86 28 85593421 Email: info@hongyuv.com...
Page 9
HY-WDC2E outlet. When the plug is connected, turn the outer sleeve clockwise and lock the plug. With 3 stainless steel screws, the HY-WDC2E can be fixed to the mounting pipe (the screw has a maximum installed torque of 4Nm). (refer to picture on the bottom)...
Page 10
Customers must ensure that the HY-WDC2E is installed in an open area so as to avoid obstacles to airflow or turbulence in the surrounding buildings. Do not install HY-WDC2E on the side of a high power radar or radio transmitter. 10.4...
Page 11
11.Optional installation pole(Cost extra 20 USD/PCS) In order to facilitate the installation for users, we specially customized a cast aluminum bracket for users’ option, installation way shown as pictures below: Hongyuv Technology Co.,Ltd Tel: +86 28 87702755 Fax: +86 28 85593421 Email: info@hongyuv.com...
There are no moving parts or user-serviceable parts requiring routine maintenance. Opening the unit or breaking the security seal will void the warranty and the calibration. In the event of failure, prior to returning the unit to your authorised HongYuv distributor, it is recommended that: 1.
Checksum sum figure is calculated from Exclusive OR of the bytes between (and not including) the $ and * characters. <CR><LF> ASCII Line Feed character Character Hongyuv Technology Co.,Ltd Tel: +86 28 87702755 Fax: +86 28 85593421 Email: info@hongyuv.com Website: www.hongyuv.com...
Once you enter secondary setting mode, you have to exit it by inputting command 17 or power off-on sensor, otherwise it will keep staying in setting mode where you can’t access to any data. Hongyuv Technology Co.,Ltd Tel: +86 28 87702755 Fax: +86 28 85593421 Email: info@hongyuv.com...
Need help?
Do you have a question about the HY-WDC2E and is the answer not in the manual?
Questions and answers