R E G U LO R 4 S U M M A R Y 1- PRESENTATION AND PREPARATION ----------------------------------------------------------- Description -------------------------------------------------------------------------------------------------------------------------------- Identification ----------------------------------------------------------------------------------------------------------------------------- Connection ------------------------------------------------------------------------------------------------------------------------------- Guarantee --------------------------------------------------------------------------------------------------------------------------------- 2- USE ------------------------------------------------------------------------------ ---------------------------- ------------ Choice of wheel or radar sensor (option) ----------------------------------------------------------------------------------------- Normal circulation ----------------------------------------------------------------------------------------------------------------------- Semi-continous or Continous Circulation ----------------------------------------------------------------------------------------- Field programming ---------------------------------------------------------------------------------------------------------------------...
Page 3
R E G U LO R 4 6- ELECTRIC CIRCUITS --------------------------------------------------------------------------------------------------------- Electric Wiring Diagram Mobile Unit Version ------------------------------------------------------------------------------------------ Electric Power for Mobile Unit ------------------------------------------------------------------------------------------------------------ 7- OPERATING ANOMALIES ------------------------------------------------------------------------------------------------- Unstable Control in Automatic Mode---------------------------------------------------------------------------------------------------- Accuracy of Flow/ha measured ----------------------------------------------------------------------------------------------------------- 8- MAIN SPARE PARTS -------------------------------------------------------------------------------------------------------- S U M M A R Y 677816 01/99...
R E G U LO R 4 1- PRESENTATION AND PREPARATION The user must record the values of the parameters contained in the Regulor. Any random changes to this data will lead either to significant errors in flow/ha or an incorrect display.
AR E A VO LU M E U SE D MANUAL VALID TEST FI EL D EVRARD GROUPE HARDI 12 11 Display data separation LED Display Display data separation LED Semi-continuous/Continuous circulation function LED Fault LED for works parameters Numeric keyboard...
VOLUME EPANDU MANUEL VALID TEST PAR C E L L E S EVRARD GROUPE HARDI H A R D I - E V R A R D 03540890 N de Série : Connection The REGULOR is connected to : ref. 1 - The battery 12 Volt by a male plug ref.
Page 7
R E G U LO R 4 P R E S E N T A T I O N A N D P R E P A R A T I O N 677816 02/99...
Page 8
R E G U LO R 4 2 - U S E When the power is connected, the Regulor display shows the following message : The DG4 regulating valve is positionned after turning to left then to the right to midway. The displays shows The remaining programming of the Regulor depends on the type of atomization selected.
Page 9
R E G U LO R 4 - Connect the spraying pump and move forwards. ref. 1 - Open the atomization on the individual switches for opening atomization sections and the general switch on the joystick . The Volume/hectare is adjusted automacally and the right part of display indi- cates the volume per hectare measured.
Page 10
R E G U LO R 4 Table for Nozzles Codes Co-efficient Code Message Type of nozzle NOZZLE 0 ......NOZZLE 1 ......NOZZLE 2 ......NOZZLE 3 ......NOZZLE 4 ......NOZZLE 5 ......NOZZLE 6 ......NOZZLE 7 ......
Page 11
R E G U LO R 4 ref. 1 - Close all sections simultaneously at the end of the field using the general switch , or independently ref. 2 using the various opening and closing switches for the sections. The number of the nozzle in use can be established while working. To do this press the nozzle button, the dis- play indicates which nozzle is used for a few seconds.
Page 12
R E G U LO R 4 Stage Number 4 Example : Field used n° Press button , the display shows : Stage Number 5 ‘VALID’ - Confirm with the button, the display shows : then Fiel n° can be used. To programm the flow per hectare, see the chapter ‘Use in Normal circulation Circulation or semi-continuous or continuous circulation depending on atomizer configuration.
Page 13
R E G U LO R 4 M o d i f i c a t i o n o f V O L U M E / H E C T A R E 1 - A U T O M A T I C PROGRAMMED VOLUME/HA - Press the ‘...
R E G U LO R 4 3 - M A N U A L The programmed flow remains set and the Volume/Hectare varies in an inversely proportional manner to speed. The Regulor acts as a atomization controller. Manual - Press ‘ ’...
R E G U LO R 4 O t h e r f u n c t i o n s The REGULOR 4 has seven other functions allowing access to the following data : S p e e d - P r e s s u r e - V o l u m e / h a ‘Speed-Pressure-Volume/Ha’...
R E G U LO R 4 P a r t i a l v o l u m e s p r e a d ‘VOLUME SPREAD ’ - Press the button once and the corresponding display appears This shows the volume spread.
REGULOR 4 3 - E R R O R M E S S A G E S Fives differents messages may appear on the Regulor displays. OVER-T ‘’PROGRAMMED VOLUME/HA ’’ Example of display with function ‘’ OVER-T’’ The cyclic display of the word and the function in progress indicates that the control nalve is at the left stop (ref zero) To cancel this message :...
REGULOR 4 OPEN This message appear 15 seconds after connecting the power if the regulating valve index has not reached its zero position. The cause is a fault in the electrical circuit (disconnected wire, fuses, micro-circuit breaker fot the regulating valve) or the valve itself (seized) - Disconnect the12 V power before checking these elements.
R E G U LO R 4 4 - P R O G R A M M I N G This mode allows monitoring of the data supplied by the sensors (flow meter, pressure, advance speed) or modification of the data stored by the Regulor4 The user should note the importance datas of the parameters contained in the Regulor 4.
R E G U LO R 4 Detailed List of ‘WORKS’ Tests TEST : Width of boom TEST : Wheel sensor used INDUCTIVE MAGNETIC RADAR TEST : Wheel circumference or radar pulse TEST : Unit value of flow meter TEST : No used TEST : Valve type :...
R E G U LO R 4 General Method WORKS The unit must be in ‘’ ‘’ mode : ‘TEST’ - Press - Enter the number of the test to modified ‘VALID’ - Press . the display shows the name of the test. One second later, the display shows the present programmed value.
Page 23
R E G U LO R 4 Two cases may occurs : ‘VALID’ For verification and if the value indicated corresponds to the working width, press the key. ‘VALID To programme a different working width, enter the new value and press the ’...
R E G U LO R 4 W h e e l c i r c u m f e r e n c e - T E S T 3 Description : Circumference for one turn of the wheel on which the speed sensor is set. TEST 3 does not applied the radar (See TEST 45).
Page 25
R E G U LO R 4 (DA) Read the distance displayed on the Regulor . If the value displayed is identical to that measured, no modificationis required to the wheel circumferen- ce programming (TEST 3). . If the value displayed differs from that measured, apply the following formula : New wheel circumference = Distance to be travelled x wheel value TEST3 (DD)
Page 26
R E G U LO R 4 valeur unitaire example : K= 0,00515 TEST VALID FLOW /HA UNIT VALUE 5% down Example :The flow/ha is in normal circulation; In this case to increase the volume/ha, you must reduce the value of TEST 4 between Note : It is important to take into account the error due to the non-regulation range, generally (see TEST 0,00489...
R E G U LO R 4 N° test Typ of nozzle Coefficient ..............................................................................................................................................IMPORTANT : In the tableabove, record the nozzles you are using and corresponding coefficients. For each type of nozzle (20to 29) the unit value is calculated as follows : Unit value ( ) = a x b ‘’TEST 4’’...
Page 28
R E G U LO R 4 T a b l e s f o r N o z z l e s c o e f f i c i e n t s ISO Nozzlzs Nozzles Number of nozzles per section Flow (l/mn) 2 bar 3 bar...
R E G U LO R 4 Nozzles Number of nozzles per section Flow (l/mn) 2 bar 3 bar 0,24 0,30 Rose 0075 10,7 12,2 13,8 15,2 16,6 21,8 24,2 26,4 0,33 0,40 Orange 01 14,1 16,1 18,0 19,8 21,5 27,8 30,5 33,1 42,3 0,49...
Page 30
R E G U LO R 4 In certain cases it not possible to use the information in the tables aboves, in particular when the nozzle used for semi-continuous or continuous circulation or the number of nozzles per section is not recorded. In these cases the coefficient must be calculated using the following formula : Calculate coefficient of nozzle Coeff.
Page 31
R E G U LO R 4 REGULOR 4 HARDI-EVRARD PROGRAMMING SHEET Typ of atomizer :....Chassis number ....Client : ............User.:................ PROGRAMMING TEST NAME PROGRAMMING TEST Boom width ....meter TEST Sensor type N° : ....1 INDUCTIVE 2 MAGNETIC...
Page 32
REGULOR 4 5 - M A I N T E N A N C E The Régulor 4 has special tests allowing checking of datas supplied by the flow meter, pressure sensor, ato- mizer, advance speed, etc..T o t a l n o z z l e s - T E S T 3 0 Description : Verification of number of nozzles programmed Nozzles None...
Page 33
REGULOR 4 BUSES 08’ The display shows that ‘ which corresponds to nozzles for boom section n° VALID TEST 31. - Press ‘’ ’’ to quit VALID F l o w m e t e r p u l s e s - T E S T 4 0 Description : Counter for flow meter pulses pulse Unit :...
Page 34
REGULOR 4 VALID TEST - Advance with atomizer, the pulse counter stars. If the figures are displayed intermittently, check the inductive speed sensor, disc or radar depending on the TEST 2 selection of TEST 41 allow determination of the radar calibration value, to do this : - Measure precisely a distance of 100 metres over even ground.
Page 35
R E G U LO R 4 VALID TEST - Open atomization, the display shows for example : litres/minute. Notes: 1- Theses tests can be carried out when stationary. 2- If this tests takes places in semi-continuous or continuous circulation, the type of nozzle must be pro- grammed in the Regulor and the valve at each end of the boom sections opened before starting this opera- tion.
Page 36
S P R A Y E D A R E A V O L U M E U S E D MANUAL VALID TEST F I E L D EVRARD GROUPE HARDI HARDI TVI 1 TVI 5 losed losed TVI 6 TVI 2...
Page 37
REGULOR 4 M A I N T E N A N C E 677816 02/99...
Page 38
REGULOR 4 6 - E L E C T R I C A L C I R C U I T S P r i n c i p e E l e c t r i c a l D i a g r a m M o b i l e U n i t V e r s i o n 1 BROWN 4 BLUE SPEED...
Page 39
REGULOR 4 Electric Power Circuit Mobile Unit Series AHM SUPPLY REMOTE VALVE PRINTED CIRCUIT CONSOLE Brun TVI8 TVI1 TVI8 TVI1 TVI7 TVI2 BLEU TVI TVI7 TVI2 TVI6 TVI3 TVI6 TVI3 TVI5 TVI4 TVI5 TVI4 Vert/JAUNE PRESSURE SENSOR REGULATING VALVE REMOTE VALVE WHEEL SENSOR FLOW METER Electric Power Circuit Mobile Unit Series ALPHA...
Page 40
R E G U LO R 4 7 - O P E R A T I N G A N O M A L I E S U n s t a b l e C o n t r o l i n A u t o m a t i c m o d e The valve regulates at constant speed Atomizer stopped - timing of centrifugal pump...
Page 41
R E G U LO R 4 A c c u r a c y o f F l o w / H a M e a s u r e d Does the distance displayed correspond to the actual distance ? Is flow/ha correct ? - check programming of wheel Test 3 - check mounting of sensor on disc (3 mm)