Check that following is
included in the package
TSS Gateway
Adapter and cable TempMonitor BLE,
START button until screen shows "dELY"¹
Press and Hold
¹
Note, when pressing START button a beep will be heard indicating that the
button is activated, ensure that button is continuously pressed for at least 5
seconds until the display changes from "Strt" to "dELY".
TempMonitor BLE Kit
Quick Installation Guide
Installation Guide
1 connected probe
with damper
Place TempMonitor BLE
outside the fridge and the
probe in its damper inside
the fridge.
+1 hour
NOTE: Ensure damper is in
its place at least 1 hour
before starting logger to
avoid temperature
excursion.
START
Place the gateway
with LED facing
upward. Antennas
mostly vertical, a
slight angle out is
recommended.
Attach country adapter and
connect the TSS Gateway to
power outlet and place it in the
same room as the TempMonitor
(Recommended distance less
than 30 meters from TempMonitor
BLE, free line of sight)
Quick Press START
button once to TURN ON logger
TOGGLE is used for toggling between (probe)
temperature sensors
COM_DEV_080 Ver G
Applicable to TM BLE FW 1.2.0 and later
Check green light indicating TSS
Gateway is powered and has
connection, this can take up to 15
minutes.
If start delay configured,
'dELY' will be displayed for the
configured time and then start
to record the data

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TempMonitor BLE Kit and is the answer not in the manual?

Questions and answers

Summary of Contents for TSS TempMonitor BLE Kit

  • Page 1 Antennas mostly vertical, a slight angle out is recommended. Attach country adapter and connect the TSS Gateway to power outlet and place it in the Check green light indicating TSS same room as the TempMonitor Gateway is powered and has...
  • Page 2 • Ensure that the START button is firmly pressed and held down until the screen changes. This can take several seconds. If the above is unsuccessful, please report back to TSS Customer service.  I’m being told there is no data in the system, although the logger seems to be working. What do I need to First, verify that the Gateway and the TempMonitor BLE is close to each other, we recommend keeping them in the same room and less than 30 meters apart.
  • Page 3 User Manual TSS TempMonitor BLE TSS AB │ Berzelius väg 25-27, 171 65 Solna, Sweden │ E-mail: customer.service@tss.se │ Phone: +46 (0) 8 630 0606 │ www.tss.se...
  • Page 4: Table Of Contents

    2.12 Calibration Expiry ......................... 14 2.13 Memory ............................15 General Logger Information ........................ 16 3.1 Logger and Probe Identification ....................16 3.2 Logger Components ........................17 3.3 Battery ............................17 Troubleshooting ........................... 18 TSS AB 2 (18) COM_DEV_081 Ver C │ www.tss.se...
  • Page 5: Introduction

    Introduction The TSS TempMonitor BLE is a wireless storage logger with an internal temperature sensor and support for up to two probes, that can communicate with TSS Gateway and TSS Mobile App. Key Features The TempMonitor BLE, Bluetooth low energy temperature data logger can be paired with TSS GW, smartphones and transmit data via Bluetooth 5.
  • Page 6: Display Interface

    Display Interface 2.1.1 LCD Symbol meaning TSS AB 4 (18) COM_DEV_081 Ver C │ www.tss.se...
  • Page 7: Lcd Text Meaning

    UPLd pending upload before Prob logger can’t be started StoP logger is stopped logger can be started because a probe is missing EXPR calibration expiry has passed, logger can’t be started TSS AB 5 (18) COM_DEV_081 Ver C │ www.tss.se...
  • Page 8: Buttons

    Button action are displayed below: START is used for waking up, starting and acknowledging alarms on logger. MUTE is used for muting/unmuting the buzzer. TOGGLE is used for toggling between temperature sensors. TSS AB 6 (18) COM_DEV_081 Ver C │ www.tss.se...
  • Page 9: Start Up Logger

    Note, when pressing START button a beep will the data. be heard indicating that the button is activated, ensure that button is continuously pressed until the display changes from “Strt” to “dELY”. TSS AB 7 (18) COM_DEV_081 Ver C │ www.tss.se...
  • Page 10: Connection And Signal Strength

    Connection and signal strength To verify that the logger has connection to TSS Gateway the Bluetooth symbol shall be visible on the LCD screen. Logger has Bluetooth connection to TSS Gateway. In case the logger cannot establish a Bluetooth connection to the Gateway the symbol will be marked with an X.
  • Page 11: Toggle Temperature Channels

    TOGGLE is used for toggling between temperature sensors. Probe 1 is selected Probe 2 is selected T is the internal temperature sensor. Note that only two channels can be active during recording. TSS AB 9 (18) COM_DEV_081 Ver C │ www.tss.se...
  • Page 12: Max And Min Temperature

    The highest (Max) and lowest (Min) recorded temperature values are displayed on the screen. It is based on the values for the Last 30 days. Max and Min temperature for the Last 30 days TSS AB 10 (18) COM_DEV_081 Ver C │...
  • Page 13: Alarms And Events

    If the temperature is still out of range during the time of acknowledgement will the cross mark (X) remain until the temperature is within range. The buzzer will be muted by the acknowledgement. If a new alarm is triggered will the buzzer continue to beep as per configuration. TSS AB 11 (18) COM_DEV_081 Ver C │...
  • Page 14: Mute/Unmute

    5 minutes. To unmute the logger, press the mute button once more. The icon will be removed indicating that the logger is no longer muted. MUTE is used for muting/unmuting the buzzer Ala rm pres ent, Buzzer active Ala rm pres ent, Buzzer muted TSS AB 12 (18) COM_DEV_081 Ver C │ www.tss.se...
  • Page 15: Battery

    Rem ove Battery Lid. The logger will automatically continue logging temperature after the new batteries have been inserted¹. If there was any unread temperature measurement, event, probe event or alarm the logger display will show TSS AB 13 (18) COM_DEV_081 Ver C │...
  • Page 16: Calibration Expiry

    2.12 Calibration Expiry When the sensor(s) have less than 60 days until they expire a General Warning symbol will be lit. Additional notifications related to the Calibration Expiry are handled by TSS Cloud. General Warning symbol is activated Note, if a sensor has expired it is not possible to start the logger.
  • Page 17: Memory

    Gateway this will not happen. In case this this message appears ensure that the Gateway is connected to power and is online. Low Memory symbol is activated General Warning symbol is activated TSS AB 15 (18) COM_DEV_081 Ver C │...
  • Page 18: General Logger Information

    Each TempMonitor BLE is identified with a unique 16-character id, located on its back. Each Probe TMBLE100, is identified with a unique 16-chracter id. The Expiry Date of the probe is stated too. TSS AB 16 (18) COM_DEV_081 Ver C │...
  • Page 19: Logger Components

    Do not dispose of the logger or batteries in fire. Do not expose the contents of the batteries to water. Dispose of the batteries according to local regulations for lithium batteries. TSS AB 17 (18) COM_DEV_081 Ver C │...
  • Page 20: Troubleshooting

    Troubleshooting Should you experience issues with any of the above steps, or with the TSS TempMonitor BLE in general, please reach out to us at customer.service@tss.se. TSS AB 18 (18) COM_DEV_081 Ver C │ www.tss.se...