  • Page 1 User & Installation Manual ECHO SOUNDER NED-3010 NED-3010 UM.E 20240307-04...
  • Page 2: Notice To Users

    Any attempt to modify the software on this device in a way not specified by NSR will result in the warranty being void. iv. Notice Please read this manual carefully to ensure proper use before installation and operation of the NED-3010. NED-3010 UM.E 20240307-04...
  • Page 3 MODIFY RECORD Modify by Date Paragraph Version Reason 2023/01/11 First edition 2023/09/23 General modification 2024/01/11 Add abbreviations 2024/03/07 Some modification NED-3010 UM.E 20240307-04...
  • Page 4: Table Of Contents

    4.4 Depth Channel ......................20 4.5 Depth Unit ........................20 4.6 Color Bar ........................21 4.7 Picture Advance ......................21 4.8 Simulation Data ......................22 5. ALERT MENU ........................23 5.1 Alert Active........................23 5.2 Alert History ......................... 26 NED-3010 UM.E 20240307-04...
  • Page 5 9.3 Cable Connection ......................44 APPENDIX I TECHNICAL SPECIFICATIONS ..............45 APPENDIX II MENU TREE ....................46 APPENDIX III SENTENCE DISCRIPTION ................47 APPENDIX IV LIST OF TERMS AND ABBREVIATIONS ............. 53 APPENDIX V INSTALLATION DRAWINGS ................. 54 NED-3010 UM.E 20240307-04...
  • Page 6: Overview

    NED-3010 echo sounder is designed for vessel navigation, which provides reliable information about the depth of water under the vessel through transducers. NED-3010 conforms to the standards of IMO MSC.74 (69) Annex 4: A.224 (VII) , IMO MSC.302 (87), IEC 61162-1, IEC 62923-1, IEC 62923-2 and ISO 9875.
  • Page 7 NED-3010 USER & INSTALLATION MANUAL The below figure is for the system diagram. NED-3010 UM.E 20240307-04...
  • Page 8: Equipment Description

    NED-3010 USER & INSTALLATION MANUAL 2. EQUIPMENT DESCRIPTION 2.1 Main Panel 2.2 Function Keys NED-3010 can be operated by key & knob on panel or touch-screen operation. Panel Key Description Turn to adjust Gain and Range. Press to switch the adjustment object between Gain and Range.
  • Page 9: Power On/Off

    NED-3010 USER & INSTALLATION MANUAL 2.3 Power ON/OFF ⚫ Power On Press shortly to power on the equipment, the main screen appears. ⚫ Power Off / Restart Press and hold till appears, choose [Power off] to power off the equipment.
  • Page 10: Main Screen Display

    NED-3010 USER & INSTALLATION MANUAL 2.5.1 Main Screen Display Description: Button Function ① MANUAL/AUTO Click to adjust mode; If AUTO, couldn’t adjust Range and Gain manually. ② Range Click to select Range, then turn to adjust the range level. ③...
  • Page 11: Screen Example

    NED-3010 USER & INSTALLATION MANUAL 2.5.2 Screen Example ⚫ Dual-Channel, A-Scope ON: ● Dual-Channel, A-Scope OFF: ⚫ Single-Channel, A-Scope ON: ● Single-Channel, A-Scope OFF: ⚫ GNSS, Position lost, Time Unsynchronized: ● GNSS, Position valid, Time Synchronized : ⚫ ): ):...
  • Page 12: Basic Menu Operation

    NED-3010 USER & INSTALLATION MANUAL 2.5.3 Basic Menu Operation Click to open the following menu (for example), it includes [Souder], [Display], [Alert], [System] and [Service] items. Menu Operation Description Exit or return to the upper menu, or cancel some setting selection windows.
  • Page 13: Sounder Menu

    NED-3010 USER & INSTALLATION MANUAL 3. SOUNDER MENU Click [MENU] - [Sounder], you can set: [Transducer 1/2], [Tx & Rx], [Depth Log] and [Sound Speed]. Single-Transducer (Single-Channel) Dual-Transducer (Dual-Channel) NED-3010 UM.E 20240307-04...
  • Page 14: Transducer

    NED-3010 USER & INSTALLATION MANUAL 3.1 Transducer Click [MENU] - [Sounder] - [Transducer 1/2], you can set: [Transducer], [Frequency], [Draught], [To Keel], [Gain] and [Interference Rejection]. Note: Locked items ( ) are only for viewing. If you want to modify it, password is needed.
  • Page 15: Draught

    NED-3010 USER & INSTALLATION MANUAL Frequency: “50kHz” or “200kHz”, default setting is “200kHz”. Normally, the higher the frequency, the better the resolution; and the lower the frequency, the wider the detection area. Note: The frequency set must be same as the transducer frequency.
  • Page 16: Gain

    NED-3010 USER & INSTALLATION MANUAL 3.1.5 Gain Gain: Adjust the sensitivity of the receiver, setting range: 1 ~ 20. 、 Note: 1 It is recommended to use lower Gain in shallow water and higher Gain in deep water. 、 While Auto Gain is active, the gain is adjusted automatically according to the depth and circumstance of water.
  • Page 17: Tx & Rx

    NED-3010 USER & INSTALLATION MANUAL 3.2 Tx & Rx Click [MENU] - [Sounder] - [Tx & Rx] , the following screen appears. You can set: [Tx Power], [Tx Rate], [Pulse Width] and [Pulse Width]. 3.2.1 Tx Power Tx Power: Set as “Auto” or “Manual”. If “Manual”, setting range: 0 ~ 100%, for example:...
  • Page 18: Tx Rate

    NED-3010 USER & INSTALLATION MANUAL 3.2.2 Tx Rate Tx Rate: Set as “Auto” or “Manual”. If “Manual”, setting range: 0 ~ 10Hz, for example: NED-3010 UM.E 20240307-04...
  • Page 19: Pulse Width

    NED-3010 USER & INSTALLATION MANUAL 3.2.3 Pulse Width Pulse Width: Set as “Auto” or “Manual”. If “Manual”, setting range: 0 ~ 20000 µs, setting screen is as follows: NED-3010 UM.E 20240307-04...
  • Page 20: Pulse Width Mag

    NED-3010 USER & INSTALLATION MANUAL 3.2.4 Pulse Width Mag Pulse Width Mag: Setting range: 0 ~ 20. NED-3010 UM.E 20240307-04...
  • Page 21: Depth Log

    NED-3010 USER & INSTALLATION MANUAL 3.3 Depth Log Interval: In Depth Log, the interval for sampling data is 1min. View: Set “Transducer 1”, “Transducer 2” or “Transducer 1+2” as follows: NED-3010 UM.E 20240307-04...
  • Page 22: Sounder Speed

    NED-3010 USER & INSTALLATION MANUAL 3.4 Sounder Speed Sounder Speed: Set range: 1400 ~ 1600 m/s. NED-3010 UM.E 20240307-04...
  • Page 23: Display Menu

    NED-3010 USER & INSTALLATION MANUAL 4. DISPLAY MENU Click [MENU] - [Display],the following screen appears, it includes [A-Scope], [Multi Echo], [Depth Datum], [Depth Channel], [Depth Unit], [Color Bar], [Picture Advance] and [Simulation Data] items. 4.1 A-Scope to set “ON” or “OFF”.
  • Page 24: Multi Echo

    NED-3010 USER & INSTALLATION MANUAL 4.2 Multi Echo Multi Echo:Select among “Transducer 1”, “Transducer 2” or “Transducer 1+2”. 4.3 Depth Datum Depth Datum: Select depth below “Water”, “Transducer” or “Keel”. NED-3010 UM.E 20240307-04...
  • Page 25: Depth Channel

    NED-3010 USER & INSTALLATION MANUAL 4.4 Depth Channel Depth Channel: Select the transducer for output sentence (Transducer 1 or Transducer 2). 4.5 Depth Unit Depth Unit: Set as “m” or “ft” (feet). NED-3010 UM.E 20240307-04...
  • Page 26: Color Bar

    NED-3010 USER & INSTALLATION MANUAL 4.6 Color Bar to set “ON” or “OFF”. Color Bar: Click 4.7 Picture Advance Picture Advance:The picture advance speed is the contact of screen refresh speed and transmission speed. You can set among “Stop”, “/ 4”, “/ 2”, “X 1”, “X 2” etc. For example: “/ 4” means four transmission get one picture displayed on the screen, “X 1”...
  • Page 27: Simulation Data

    NED-3010 USER & INSTALLATION MANUAL 4.8 Simulation Data Simulation Data: It provides simulated data without connection of the transducer. Click set “ON” or “OFF”. NED-3010 UM.E 20240307-04...
  • Page 28: Alert Menu

    NED-3010 USER & INSTALLATION MANUAL 5. ALERT MENU Click [MENU] - [Alert], the following screen appears, it includes [Alert Active], [Alert History] and [Depth Alarm Threshold] items. 5.1 Alert Active Alert Active list includes: NED-3010 UM.E 20240307-04...
  • Page 29 NED-3010 USER & INSTALLATION MANUAL ⚫ Acknowledge: Click to acknowledge the alert selected. For example: ⚫ Silence: Click to mute all alerts. For example: ⚫ Alert Detail: Press and hold any alert item (such as 001) in the list to view the details. For example:...
  • Page 30 NED-3010 USER & INSTALLATION MANUAL Alert Mark Description Table: Mark Priority State ACTIVE-UNACKNOWLEDGED ACTIVE-SILENCED ALARM ACTIVE-ACKNOWLEDGED ACTIVE-RESPONSIBILITY TRANSFERRED RECTIFIED-UNACKNOWLEDGED ACTIVE-UNACKNOWLEDGED ACTIVE-SILENCED WARNING ACTIVE-ACKNOWLEDGED ACTIVE-RESPONSIBILITY TRANSFERRED RECTIFIED-UNACKNOWLEDGED CAUTION ACTIVE Alert Description Table: Alert Alert Alert Alert Title Additional Description Instance Category...
  • Page 31: Alert History

    NED-3010 USER & INSTALLATION MANUAL Alert Configuration Table: Permission Alert Alert Alert Escalation Permission Transfer of Instance Category Priority Properties Acknowledge Responsibility 3031 ALARM WARNING 3062 WARNING WARNING 3062 WARNING WARNING 5.2 Alert History Alert History list is as right, up to 100 records.
  • Page 32: System Setting

    NED-3010 USER & INSTALLATION MANUAL 6. SYSTEM SETTING Click [MENU] - [System], the following screen appears, it includes [LCD Display], [NMEA], [Date & Time] and [Audio] items. 6.1 LCD Display Click [MENU] - [System] - [LCD Display], the following screen appears, it includes [Language], [Theme] and [Brightness].
  • Page 33: Language

    NED-3010 USER & INSTALLATION MANUAL 6.1.1 Language Language: Select the language to be used (English or Chinese). Please restart the system after selection. 6.1.2 Theme Theme: Set the display mode (Day or Night). NED-3010 UM.E 20240307-04...
  • Page 34: Brightness

    NED-3010 USER & INSTALLATION MANUAL 6.1.3 Brightness Brightness: Slide or pull down to adjust the brightness of screen. 6.2 NMEA Click [MENU] - [System] - [NMEA], the following screen appears, it includes Baud Rate of [GNSS], [BAM], [Data] and [Printer] (Type, Output also) items.
  • Page 35: Baudrate

    NED-3010 USER & INSTALLATION MANUAL BaudRate 6.2.1 GNSS/BAM/Data: Set Baud Rate of each port as 4800 or 38400. 6.2.2 Printer Printer: Set Baud Rate of printer port. Type: Set type of printer. NSR NPT-100 printer is recommended. to set printer output “ON” or “OFF”.
  • Page 36: Date & Time

    NED-3010 USER & INSTALLATION MANUAL 6.3 Date & Time Click [MENU] - [System] - [Date & Time], the following screen appears, it includes [Mode], [GNSS Sync], [Date], [Time] and [Local Time Zone] items. 6.3.1 Mode Mode: The displayed time can be selected between “UTC” and “Local Time”.
  • Page 37: Gnss Sync

    NED-3010 USER & INSTALLATION MANUAL 6.3.2 GNSS Sync to set “ON” or “OFF”. GNSS Sync: Click ): Time is automatically synchronized with GNSS sentence, “Synchronized” is displayed as ON ( follows. ): Time can be set manually. “Unsynchronized” is displayed as follows.
  • Page 38: Date

    NED-3010 USER & INSTALLATION MANUAL 6.3.3 Date Date: Set the date manually when [GNSS Sync] setting is “OFF”. NED-3010 UM.E 20240307-04...
  • Page 39: Time

    NED-3010 USER & INSTALLATION MANUAL 6.3.4 Time Time: Set the time manually when [GNSS Sync] setting is “OFF”. 6.3.5 Local Time Zone Local Time Zone: Pull down to set the local time zone. For example: “UTC +08:00 China Beijing”. NED-3010 UM.E 20240307-04...
  • Page 40: Service

    NED-3010 USER & INSTALLATION MANUAL 7. SERVICE Click [MENU] - [Service], the following screen appears, it includes [About Device], [Built-In Test], [Com Monitor], [Key Check], [LCD Check], [Audio Check] and [Advanced] items. 7.1 About Device Click [MENU] - [Service] -[About Device], the following screen appears, you can check the device name, version information, and update the software.
  • Page 41: Device Information

    NED-3010 USER & INSTALLATION MANUAL 7.1.1 Device Information As shown above, you can check the following device information (for example): Device: Device Name (Echo Sounder). Model: Device Model (NED-3010). Version Date: Current Version Date. Version Code: Product Version (1.0.0). Module: Module Name.
  • Page 42 NED-3010 USER & INSTALLATION MANUAL ② After the upgrade App is found, the following screen appears: ③ Select the app, click INSTALL to start the installation. NED-3010 UM.E 20240307-04...
  • Page 43: Built-In Test

    NED-3010 USER & INSTALLATION MANUAL 7.2 Built-In Test Click [MENU] - [Service] - [Built-In Test], the following screen appears, it includes: [Echo Module], [Depth Log], [Alert History], [NMEA] and [Crash] items. You can check OK or not. 7.3 Com Monitor It’s to check the communication sentences on the I/O ports.
  • Page 44: Key Check

    NED-3010 USER & INSTALLATION MANUAL Port: Pull down to select the ports. For example: 7.4 Key Check Click [MENU] - [Service] - [Key Check], the keys pressed will be displayed. For example: 7.5 LCD Check Click [MENU] - [Service] - [LCD Check], the following screen appears. Click on the screen to start the test and press to stop the test.
  • Page 45: Audio Check

    NED-3010 USER & INSTALLATION MANUAL 7.6 Audio Check Click [MENU] - [Service] - [Audio Check], alarm sounds 3 times. 7.7 Advanced The access for [MENU] - [Service] - [Advanced] is only for authorized service engineers and the password is required. Please contact NSR or local agent.
  • Page 46: Maintenance

    NED-3010 USER & INSTALLATION MANUAL 8. MAINTENANCE 8.1 ROUTINE MAINTENANCE In order to keep system functioning, routine maintenance is necessary. Check below once a month. Item Description Item Cable Cables non damage and exposed. Replace the damaged parts.。 ⚫ Tighten loosened connections.
  • Page 47 NED-3010 USER & INSTALLATION MANUAL Problem Probable cause Remedy ⚫ Adjust the gain. ⚫ Low gain setting. ⚫ Remove marine life ⚫ Marine life on transducer surface. Irregular display transducer surface when dry docked. ⚫ Low reflectivity from seabed. ⚫ Suspect muddy seabed. Note the reflectivity.
  • Page 48: Installation

    NED-3010 USER & INSTALLATION MANUAL 9. INSTALLATION 9.1 Installation of Display Unit The display unit can be installed on a table-top, on the overhead, or in a panel (optional flush mounting brackets required). Refer to the outline drawings at the end of this manual for installation instructions.
  • Page 49: Cable Connection

    NED-3010 USER & INSTALLATION MANUAL 9.3 Cable Connection The port descriptions is as follows. Please refer to the installation drawings for cable connection. GNSS Port: IEC 61162-1 & IEC 61162-2 BAM Port: IEC 61162 -1 & IEC 61162-2 Data Port: IEC 61162 -1 & IEC 61162-2...
  • Page 50: Appendix Itechnical Specifications

    NED-3010 USER & INSTALLATION MANUAL APPENDIX I TECHNICAL SPECIFICATIONS ⚫ General Channel: 2 channels Frequency: 200 kHz or 50 kHz Measure Range: 0.3 ~ 200m (200 kHz), 2 ~ 200 m (50 kHz) TX Power: 600 W ⚫ Power Supply...
  • Page 51: Appendix Ii Menu Tree

    NED-3010 USER & INSTALLATION MANUAL APPENDIX II MENU TREE MENU Sounder Transducer 1 Transducer Transducer 2 Frequency Draught To Keel Gain Interference Rejection Tx & Rx Tx Power Tx Rate Pulse Width Pulse Width Mag Depth Log Interval View Sound Speed (1400~1600 m/s)
  • Page 52: Appendix Iii Sentence Discription

    NED-3010 USER & INSTALLATION MANUAL APPENDIX III SENTENCE DISCRIPTION I/O Sentences Input sentences (IEC 61162-1 & IEC 61162-2) GNSS port: GGA, ZDA, GLL, RMC BAM port: ACN Output sentence (IEC 61162-1 & IEC 61162-2) BAM port: ALF, ALC, HBT, ARC...
  • Page 53: Gll - Geographic Position - Latitude/Longitude

    NED-3010 USER & INSTALLATION MANUAL ZDA - Time and date $--ZDA,hhmmss.ss,xx,xx,xxxx,xx,xx*hh<CR><LF> | +----------- 6 +-------------- 5 +------------------ 4 | +---------------------- 3 +------------------------- 2 +--------------------------------- 1 1. UTC 2. Day, 01 to 31 (UTC) 3. Month, 01 to 12 (UTC) 4. Year (UTC) 5.
  • Page 54 NED-3010 USER & INSTALLATION MANUAL RMC- Recommended minimum specific GNSS data $--RMC,hhmmss.ss,A,llll.ll,a,yyyyy .yyy,a,x.x,x.x,xxxxxx,x.x,a,a,a*hh<CR><LF> | | | | | | | | | | | | | +-----------------------10 | | | | | +-------------------- 9 | | | +--+------------------ 8 | | |...
  • Page 55 NED-3010 USER & INSTALLATION MANUAL ALF - Alert sentence $--ALF, x, x, x, hhmmss.ss, a, a, a, aaa, x.x, x.x, x.x, x,c---c*hh <CR><LF> | | | | | | | | | | | | | | | | +------------------------ 13...
  • Page 56 NED-3010 USER & INSTALLATION MANUAL ALC - Cyclic alert list $--ALC, xx, xx, xx, x.x, aaa, x.x, x.x,x.x, .., aaa, x.x, x.x, x.x*hh <CR><LF> +-----------------+----------- 7 +--+-------------------------- 6 | +----+----+--+------------------------------ 5 +---------------------------------------------- 4 +--------------------------------------------- 3 | +------------------------------------------- 2 +------------------------------------------ 1...
  • Page 57 NED-3010 USER & INSTALLATION MANUAL HBT – Heartbeat supervision sentence $--HBT, x.x, A, x*hh<CR><LF> | | | | | +--------------------- 3 | +------------------- 2 +------------------- 1 Configured repeat interval Equipment status Sequential sentence identifier DPT – Depth $--DPT, x.x, x.x, x.x*hh<CR><LF>...
  • Page 58: Appendix Iv List Of Terms And Abbreviations

    NED-3010 USER & INSTALLATION MANUAL APPENDIX IV LIST OF TERMS AND ABBREVIATIONS Term Meaning Bridge Alert Management Communication EPFS Electronic Position Fixing System Feet FORE Fore Global Positioning System Knots Liquid Crystal Display Meters Magnification NMEA National Marine Electronics Association...
  • Page 59: Appendix V Installation Drawings

    TRANSDUCER&TRANSDUCER TANK SIZE DRAWING NED3010/3007-ID-006 NXT-100 TRANSDUCER TANK WELDING DRAWING NED3010/3007-ID-007 NED-3010 DISPLAY UNIT SIZE DRAWING NED3010/3007-ID-008 NED-3010 DISPLAY UNIT MOUNTING DIAGRAM (TABLE TYPE) NED3010/3007-ID-009 NED-3010 DISPLAY UNIT MOUNTING DIAGRAM (FLUSH TYPE) NED3010/3007-ID-010 JUNCTION BOX SIZE DRAWING NED-3010 UM.E 20240307-04...
  • Page 70 Copyright by NEW SUNRISE CO., LTD. (NSR) www.nsrmarine.com info@nsrmarine.com March, 2024...