Page 1
ERunner drive system* Installation instructions for ERunner model ERRWL-LS241 System RAUVOLET vetro-line 2.1 * hereinafter referred to as ERunner...
Page 2
Index About these installation instructions Target group Safety instructions and warnings Safety Standard delivery contents Approved dimensions Installation of cabinet carcass Installation of control panel and guide rails Installation of ERunner and other components Installation of tambour door Installation of drive cord Connection and cable management Installation of cover plate Commissioning...
About these installation instructions ▪ Read through the installation instructions and particularly the safety instructions before using the ERunner for the first time. ▪ Keep the installation instructions safe for later consultation. These installation instructions are not intended for the end user. They serve solely as a source of information for the cabinet manufacturer and describe the installation and usage of the ERunner.
Page 4
▪ Ensure that moisture cannot enter the inside of the drive system. ▪ Do not perform any repairs on the ERunner. In the event that repair is required, contact REHAU. ▪ This device may not be used by persons with limited physical, sensory or mental capacity or without the required experience and/or the required know-how.
Page 5
04.06 Damage to the ERunner or the control panel If you find that the ERunner is no longer working correctly, please contact REHAU. ▪ Do not perform any repairs on the ERunner on your own. ▪ Do not make any changes to the ERunner. Unauthorised repairs and changes to the ERunner can lead to incalculable risks.
Page 6
Deflection pulley (2x) with screws (6x) c Reed contact (1x) with screws (2x) d Magnets (2x) e ERunner AC adapter (1x) REHAU AC adapter cable (1x) type E/F (alternative type G, J) ERunner control panel g ERunner PURE small (1x) with cable (1x)
Page 7
Additional components h C9 mechanics (2x) Rear high deflecting plate (2x) k Front low deflecting plate (2x) End lamella set (1x) m Additional centre slat (1x) n Connection bracket (2x) p Rear deflection (1x right, 1x left) q Top guide profile (2x) End caps (2x right, 2x left) Front deflection (1x right, 1x left) Guide rail (1x right, 1x left)
Page 8
8 x spacer plates front and rear, 4x15 mm with cross slot 4 x deflection Cable channel 10x15 mm approx. 1.2 m Fixing of cable REHAU plastic lubricant 5 ml tube 1 pc Greasing the track system (material number: 17799941001) Base beam for inspection...
Page 9
[2*] [2*] Dimension drawings for preparing the 117.4 [6*] carcass parts can be provided by 25 [6*] REHAU upon request. 226.2 [1*] Example - pre-drilling structural Z (1 : 1) shelf: Infer position of the drill holes Right side Cabinet carcass...
Page 10
Installation of control panel and guide rails Installing control panel: Insert cable into the guide profile using suitable installation tool (e.g. 10-mm Teflon tape). Let the plug protrude 40 mm from the cable Carefully clip the guide profile with assembled cable into the guide rails. Let the plug protrude 40 mm Carefully clip the control panel on the cable plug with the black contact...
Page 11
Install the control panel cable behind the front deflection Insert the front deflection into the guide rails Press guide rails with front deflection flush into the grooves Ensure that the cable does not get clamped during assembly Guide the cable behind the front deflection along the side wall Assemble the front deflection with countersunk head chipboard screw...
Page 12
Installation of ERunner and other components The structural shelf must be prepared in order to install the components. The respective screw position of the components is indicated in the dimension drawing for the structural shelf (s. Kap. 07). Initial situation: Prepared cabinet with structural shelf for installing the ERunner components Assemble reed contact on the right...
Page 13
Install deflection pulleys on the left and right using the screws supplied Caution, risk of friction and abrasion due to motor-operated drive cords! The power supply unit may not be connected to the power supply yet! a Front drive cords b Rear drive cords c End lamella clip d Cord adapter...
Page 14
Using the end lamella clip (c) guide the drive cords going to the back (b) over the deflecting plate and fix it to the cabinet rear shelf using adhesive tape Guide the drive cord going to the front (a) and the cord adapter (d) over the deflection pulleys and the deflecting plate (a) and fix it at the front on the inner side wall using adhesive tape...
Page 15
Fasten end lamella (e) and additional centre slats to the end rod (b) using the connection bracket (c) Magnet is already pre-installed as an option. Otherwise, carefully insert the first magnet using a rubber mallet, as shown, in the end lamella (e). The magnet is in a mounted state on the side of reed contact.
Page 16
Apply plastic lubricant to the contact area of guide system (Recommendation: REHAU plastic lubricant; 5 ml tube; mat. no. 17799941001) Caution, crushing hazard! It is recommended to wear safety gloves. Place cabinet on the side and mount tambour door as far as possible (up to the rear stop of the bent guide profile).
Page 17
Installation of drive cord Rear drive cords Assemble end lamella clip to the end lamella using rear drive cords and the screws supplied Caution! Do not clamp drive cords when doing this! Insert connection cable of the power supply unit into the drive unit (s. Kap. 12) Caution! Do not connect the power supply unit to the power supply yet.
Page 18
Slowly close the tambour door until the front drive cords are lightly tensioned Individual parts of the end lamella clip a Tension spring b Slider c Threaded pins d Cord winding Loosen threaded pins. Tighten drive cords (cords must run over the deflecting plate, s.
Page 19
Connection and cable management 12.01 Connection management Connections to drive system a Reed contact b REHAU AC adapter c ERunner control panel d USB type B for firmware update 12.02 Cable management Store excess cable on the structural shelf in the rear right deflecting plate Caution! Do not squeeze, kink or clamp cable.
Page 20
Installation of cover plate Dampen the drillholes for the bottom beam for inspection on both sides using quick binder glue and attach bottom beam using rubber mallet. Caution! Check the correct position of the front and rear drive cords over the deflecting plate before installing the inspection base! Plug pilaster strip with the spring...
Page 21
Commissioning 14.01 General information Upon delivery, the ERunner is generally in the service mode. The ERunner can also be put in the service mode manually by simultaneously holding the sensor keys OPEN and CLOSE for 10 seconds (they must be released after 10 seconds) (s. Kap. 18). 14.02 Service mode In service mode, the ERunner works with reduced speed and can be driven by holding the OPEN and CLOSE sensors.
Operation The ERunner is controlled using a control panel in the frame profile of the tambour door cabinet. ERunner PURE small OPEN • Top sensor opens the tambour door (OPEN) • Lower sensor closes the tambour door (CLOSE) ERunner can be stopped any time by pressing any sensor. CLOSE Obstacle detection The ERunner has an obstacle detection function in the upward as well as downward direction.
Page 23
Warning! Don't disconnect the power supply before carrying out the emergency opening of the ERunner tambour door cabinet (remove plug) Unfasten inspection base and remove pilaster strip Unwind the cord on the end lamella clip. Loosen threaded pins on the end lamella clip on the rear using a 1.5 mm hexagonal key up to the point where the cord can move (do not loosen...
Page 24
Malfunctions/repairs In the event of a malfunction or defect, please contact REHAU. ▪ Do not make any changes to the ERunner. ▪ Never put a damaged ERunner into operation. Malfunction What needs to be done? Carry out the steps of the sequence in order to determine or limit the cause of the malfunction.
0.15 m/s opening 0.10 m/s closing A-weighted emission sound pressure LpA ≤ 70 dB(A) Connections a Reed contact , b REHAU AC adapter, c ERunner control panel, d USB type B for firmware update Ambient conditions Operating temperature +15 to +35° C Storage temperature -20 °C to +70 °C...
Please dispose of the used batteries in an orderly manner. For this, observe the disposal instructions of the battery manufacturer on the packaging. Th ERunner drive system, the REHAU AC adapter, the control panel and the REHAU AC adapter cable are electronic devices and must be disposed separately from domestic waste according to the WEEE directive 2012/19/EU.