Advertisement
The NF-521 is a thermal imaging camera that combines surface temperature measurement and real-time thermal imaging The thermal imager is effective in converting thermal radiation images into visible light images. It is mainly used for building diagnostics, industrial leak detection, and electromechanical testing and so on.
1 | Master (included a 16GB TF card & lithium battery) | 1 pcs |
2 | USB cable, 16GB micro TF card | 1 pcs |
3 | Carry bag | 1 pcs |
4 | Manual | 1 pcs |
5 | Certificate | 1 pcs |
In the shutdown state, press the key (about 6 seconds) until the welcome interface appears and release to complete the start up.
In the power on state, press the key (about 3 seconds) when not enter any setting interface, until the shutdown confirmation interface appears. Press the
key to cancel the shutdown and press the
key to confirm the shutdown.
key (display mode) present in turn: infrared mode / infrared edge detection mode / dual light fusion mode.
Color plate switching sequence of NF-521 shown as below
key (display mode) present in turn: Iron red / Cold color / Black heat / Rainbow / Red heat / White heat / Lava.
When not enter any setting interface, the white center point on the screen represents the temperature value of the point, and the numerical value is displayed in the lower left corner of the screen; the red dot represents the maximum temperature of the whole screen, and the numerical value is displayed in the upper left corner.
The green dot represents the lowest temperature of the whole screen, and the numerical value is displayed under the right color board, shown as right side.
When not enter any setting interface, press trigger key to enter the photography interface. Press key to save and press
key to give up.
When the device system is on, press key, press
key to select the unit, press
key to activate, press
key to adjust the unit value, and press
key to exit.
The unit includes: ºC/ºF/K.
It represents the thermal reflectivity of the surface of the object. When measuring different objects, the numerical value should be adjusted to the corresponding reflectivity, so the temperature measurement will be accurate.
When the system is on, press key, press
key to select emissivity, press
key to activate, press
key to adjust emissivity, and press
key to exit.
Emissivity: 0. 1-1.0 adjustable.
The large interval shutter can make the image clear and the temperature measurement accurate. Industrial temperature measurement interval is generally 3 minutes; temperature measurement interval is generally 1 minute.
Before enter any interface, press to select file management, and then you can view pictures option and view video option; select the object to view and enter the interface; if there is no content, prompt no content and return.
Press to view other pictures or videos In the picture viewing state, press the trigger key, you can switch the display of the corresponding visible light image.
In the video viewing state, press the trigger key to play or pause the video. Press to enter the delete current picture option or delete current video option; continue to press
to delete, and press
to cancel.
In the main menu, press Up and Down keys to move the cursor to more settings, press key, and then press
key to select the language, press
key to activate, press
key to select the language you need, after selection, press
key to save and exit.
As shown in the pictures below
In Settings menu, press Up and Down key to select the date and time option; press to enter the modification, select 00 / 01 / 01 00:00 12 (year / month / day/hour/minute: 12- hour or 24-hour time display);press Up and Down key to add or subtract; press
to confirm and enter the next item; when all settings were completed, press
to save and exit.
The technology is used to adjust the fusion position Of visible light and infrared light, switch the display mode to dual light fusion mode, and aim the thermal imager at the heat source to be adjusted at the same time; then press to select settings option, press
to select image fusion option.
Image zooming is used to adjust the magnification of visible light, so as to be consistent with the size Of infrared image. Adjust the cursor up and down to select image zooming. Press key, the interface will disappear, and the red font value will appear in the middle and lower position. Then press
key to adjust until the size of infrared image object is the same as that of visible light image object. Press
to confirm and return.
Left and right adjustment is used to set the left and right cursors of visible light and infrared; up and down adjustment is used to set the up and down coordinates of visible light and infrared. The adjustment method is the same as above.
The first line in the upper left corner of the screen represents the maximum temperature of the whole picture, and the second line represents the minimum temperature of the whole picture;
In the alarm setting menu, the high temperature value means that if the temperature of the whole picture exceeds this value, it will alarm (the high temperature value will turn red); the low temperature value means that if the temperature of the whole picture is lower than this value, it will alarm (the low temperature value will turn red); after adjusting these two values, turn on the alarm switch.
When no setting interface is entered, long press the trigger key until 30s appears in the middle and lower position Of the screen, release the trigger key and start recording; the default recording time is 30 seconds, and a prompt box will appear after the recording is finished; the confirm key means save, and the power key means cancel; If you want to end the video recording in advance, just short press the trigger key again.
When enter settings interfaces, move the cursor to the auto shutdown option, and press to set the auto shutdown. There are 15 minutes, 30 minutes, and 1 hour to choose. After setting the auto shutdown time, press
to save and exit.
The system has built-in 2GB storage space, which can play video content of pictures. Insert the TF card into the card and hold it for about 2 seconds, and the TF Card icon will appear in the upper right corner. Select settings - data output option.
When enter settings interfaces, move the cursor to the system information option, and press to check the details of the whole device.
When power on, the battery symbol in the upper right corner Of the screen represents the current power. When the battery symbol turns red, it means that it needs to be charged right now, otherwise it will be automatically shut down due to low power. When charging, use the Micro USB data cable and plug it into the 5V charger for charging.
When the charger powers on, the charging symbol in the upper right corner of the screen turns green and the charging status is dynamically displayed. When power off, the battery symbol in the center Of the screen dynamically displays the charging state.
Language | Chinese / English |
Thermal imaging resolution | 32*32 (1024 pixels) |
Electronic shutter | No |
Visible light camera | 2 megapixels |
Display resolution | Thermal imaging, thermal mixing, digital camera |
Color palettes | Iron red / rainbow / black & white |
Infrared spectral bandwidth | 8~14 μm |
FOV | 33º horizontal |
IFOV | 18 mrad |
Thermal imaging sensitivity | 150mk |
Frame rate | ≤9Hz |
Image format | BMP |
Temperature measurement range | -20~400ºC |
Basic accuracy | 0ºC to 400ºC Accuracy: ±1.8% or ±1.8ºC, -20 to -0.9ºC Accuracy: ±3ºC, Test conditions, emissivity: 0.95 Ambient temperature: 25±2ºC |
Emissivity | adjustable 0.1~0.99 |
Measuring resolution | 0.1ºC/ºF |
Response time | 150ms |
Spectral band | 8~14um |
Device size (LxWxH) | 60*120*210mm |
Monitor | 2.4 & rdquo; TFT LCD |
Display resolution | 320*240 pixels |
Battery | 3.7V/2600 mAh |
Automatic shutdown function | Yes |
Certification | CE |
SD card | 16GB Micro TF card |
Working temperature | -100-450, 14 F-113 F |
Drop proof | 1M (3.28inch) |
Standard accessories | Charging, manual, USB cable, 16GB micro TF card |
Note: when the measured temperature is not accurate, you can try moving the device and changing the distance from the target to get a close temperature value.