Display is blank | - Check circuit breaker and reset if necessary.
- Make sure power switch at heating and cooling system is on.
- Make sure furnace door is closed securely.
- Make sure C wire is connected.
|
Cannot change system setting to Cool | - Check that System Setup screen "Your thermostat controls" or "Your system type" is set to match your heating and cooling equipment.
|
Fan does not turn on when heat is required | - Check that System Setup screen "Your fan control" is set to match your heating equipment.
|
"Wait" appears on the screen | - Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.
|
Heat pump issues cool air in heat mode, or warm air in cool mode | - Check your setting for System Setup screen "Type of changeover valve" to make sure it is properly configured for your system.
|
Heating or cooling system does not respond | - Touch SYSTEM to set system to Heat. Make sure the temperature is set higher than the Inside temperature.
- Touch SYSTEM to set system to Cool. Make sure the temperature is set lower than the Inside temperature.
- Check circuit breaker and reset if necessary.
- Make sure power switch at heating and cooling system is on.
- Make sure furnace door is closed securely.
- If "Wait" is displayed, the compressor protection timer is on. Wait 5 minutes for the system to restart safely, without damaging the compressor.
|
Heating system is running in cool mode | - Check that System Setup screen "Your thermostat controls" or "Your system type" is set to match your heating and cooling equipment (see "System Setup Options (MENU > System Setup)".
|