GAOTek -MGD-132 Manual

Methane gas leak detector

Advertisement

Quick Links

Product Name
Product SKU
Product URL
Based in New York City & Toronto, GAO Tek Inc. is ranked as one of the top 10 global B2B technology suppliers.
GAO ships overnight within the U.S. & Canada & provides top-notch support thanks to its 4 decades of
experience.
GAOTek Methane Gas Leak Detector
https://gaotek.com/product/gaotek-
methane-gas-leak-detector-3/
Contact us:
sales@gaotek.com
GAOTek-MGD-132
P a g e | 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAOTek-MGD-132 and is the answer not in the manual?

Questions and answers

Summary of Contents for GAOTek GAOTek-MGD-132

  • Page 1 P a g e | 1 Product Name GAOTek Methane Gas Leak Detector Product SKU GAOTek-MGD-132 https://gaotek.com/product/gaotek- Product URL methane-gas-leak-detector-3/ Contact us: sales@gaotek.com Based in New York City & Toronto, GAO Tek Inc. is ranked as one of the top 10 global B2B technology suppliers.
  • Page 2: Table Of Contents

    P a g e | 2 Table of Contents Chapter 1: Product introduction ....................3 Brief introduction ......................3 Specification .........................4 Chapter 2: Operation ......................5 Packing List ........................5 Power on/off .........................5 Operation ........................6 Advanced operations .....................8 Exit menu ........................10 Chapter 3: Maintenance ..................... 11 Daily maintenance ......................
  • Page 3: Chapter 1: Product Introduction

    P a g e | 3 Chapter 1: Product introduction 1.1 Brief introduction The product adopts the semiconductor principle and can be widely used in the leak detection of natural gas, methane heating system, gas valve, standard instrument and pipeline. The overall design of the instrument is small and exquisite, which greatly improves the comfort of customers.
  • Page 4: Specification

    P a g e | 4 Filter Indicator light Screen Gooseneck Buzzer Alarm light Body Charging port Button Handle Nameplate Lanyard hole Power light: steady green when working Fault light: steady yellow light when the instrument is blocked or the sensor is faulty. Charging light: red when charging, off when finish charging Left button: UP、Zero cal...
  • Page 5: Chapter 2: Operation

    P a g e | 5 Charging voltage DC5V Charging time Continuous not less than 8h operation time Dimensions 187mm*67mm*42mm Without probe Weight About 0.3kg Chapter 2: Operation 2.1 Packing List Please confirm if the package is complete before use. If there is any loss, please contact us as soon as possible.
  • Page 6: Operation

    P a g e | 6 In the main interface, press the left button to adjust zero, press the right button to mute the alarm. Shutdown In the main interface, long press the middle button to enter the shutdown interface, and release the button to enter the shutdown state.
  • Page 7 P a g e | 7  Alarm history After entering the menu, short press the left button or right button to select the “ALARM HISTORY” option, short press the middle button to enter the alarm history interface. Press and hold the middle button to exit the alarm history interface and return to the menu interface.
  • Page 8: Advanced Operations

    P a g e | 8 After entering the menu, short press the left button or right button to select the “SELF TEST” option, short press the middle button, it enters the self-test state. The display shows red, yellow, blue, white and black in turn, the lights flash in sequence, and the buzzer sounds once. It loops twice like that.
  • Page 9 P a g e | 9 After entering the user menu, short press the left button or right button to select the “SETTINGS” option, short press the middle button to enter the factory setting input password option, enter the correct password to enter the factory setting interface. ...
  • Page 10: Exit Menu

    P a g e | 10 After entering the factory setting interface, short press the left key or right key to select the "alamr-2 set" option, and short press the middle key to enter. In the calibration setting, short press the left or right button to adjust the value, and short press the middle button to adjust the number of digits.
  • Page 11: Chapter 3: Maintenance

    P a g e | 11 Chapter 3: Maintenance 3.1 Daily maintenance Charging There is a power indicator in the upper right corner of the display. When the battery is in low power, it should be charged in time. The charging port is a standard USB charging port. When charging, the original charger can be used, and the standard data cable can also be used for charging.
  • Page 12: Trouble-Shooting

    P a g e | 12 The following conditions are not covered by the free repair unless agreed by AIYI, please note:  Use, or maintain the product to result in damage to the product without in accordance withthe instructions ...