® more than underfloor Product code: 41440 Model: APE25-7-130 ( T1 ) EEi :!:: 0.21 -Ground motor before connecting to power supply. -Earthing terminals must be connected before operation Warning -Do not run the pump without water. AMBIENTE SYSTEMS LTD...
Specific at ion AMB I ENTE SYSTEMS LTD CONTENTS 1 In tro d uc t i o n --------------------------------------------------------- 2 P ro fil e a nd dimensions ------------------------ ------------------------ ------------------ --------------- --------------- - 2 .1 Model in s truction s ------------------------ -------------- 2.2 Model and function ov erview--- ------------------------------------------------------...
Page 3
AMBIENTE SYSTEMS LTD Specification CircoMax 3 water circulating pump Warranty Card Dear Customer: Thanks for purchasing this product and sincerely hope that you will enjoy more happiness and leisure for your choice. Now, please read and fill out this Warranty Card carefully. You will obtain reasonable and reliable guarantee and at the same time enjoy high quality service during warranty period as a result.
Page 4
Specification AMBIENTE SYSTEMS LTD � Thank you very much for choosing our company's products. Please read the instructions carefully and save it properly before installation and use. 6 Warnings • Please read the instructions carefully before installation and use. • The electric pump must be reliably grounded and installed with leakage protection devices before use.
AMBIENTE SYSTEMS LTD Specification APE-T(1) High Efficiency Circulation Pump (hereinafter called as "electronic pump"). The stator of the motor is completely shielded, and the rotating parts are immersed in clean water, playing an important role in cooling and lubricating during working. The shielding sleeve of the electric pump adopts thin-wall structure to completely shield the internal stator of the motor from water, the traditional mechanical seal structure is eliminated and the leakage problem of conventional water pump is solved.
Specification AMBIENTE SYSTEMS LTD • Ground motor before connecting to power supply. • Do not touch the pump while it is running. • Do not run the pump without water. Warning 3.1 The power supply voltage of the electric pump is single phase 230V, and the frequency is 50/60hz.
Page 8
AMBIENTE SYSTEMS LTD Specification Maximum pressure of electric pump, 1. 0MPa (10bar) In order to avoid the gas etching noise and damages to the pump bearing, the minimum pressure must be maintained at the pump intake port. Liquid ss·c go·c °...
AMBIENTE SYSTEMS LTD Specification 4.2 Liquid temperature and ambient temperature Do not touch the surface of the control box to avoid scald when the pump is running ° 2-110 Liquid temperature(t,)( ° Ambient temperature(t)( 0-40...
Specification AMBIENTE SYSTEMS LTD 4.3 Installation The motor shaft must be kept in horizontal direction when installing, the liquid flowing direction in pipe must be same with the arrow marked on pump body. Step 2 Step 3 Step 1 Correct installation location of motor...
AMBIENTE SYSTEMS LTD Specification 4.4 Control box positions The following operations can only be completed by qualified personnel. [)Installation direction preview (2)Cut off the power before adjusting @Empetying the liquid in the system and turn off the valve High pressu �...
Specification AMBIENTE SYSTEMS LTD 4.5 Electrical connection Electrical connection (Zl Point the plug at the socket of ® Complete assembly CD Installation position the control box and push it in 5.1 The control panel LEDs Button...
AMBIENTE SYSTEMS LTD Specification 5.3 Relationship between electric pump setting and lighted area Electric pump mode is setup with different display areas like below: Model Pressing time Display Descriptions CS Ill (Factory Setti n gs) Constant curve, spe ed Ill...
AMBIENTE SYSTEMS LTD Specification 5.4 Other functions Function Description Operation Operation v ent the air inside the Press and hold the button for 5 seconds until LED1+LED2 Iii] pump to ensure normal wor14 Venting +LED3 are all lit and then release. The pump wil vent...
AMBIENTE SYSTEMS LTD Specification Symptom Likely causes What to do Make sure the power cable is Loose power cable connection connected securely and firmly The pump is not Control electronics damaged Replace the control box working The impeller, motor may be wound by...
Page 17
AMBIENTE SYSTEMS LTD Specification Prot.ction type LikelycausH Disassemble the motor and check if the rotor can rotate normall y . If Locked-rotor protection The rotor is blocked not then cl e an up the impurities to make the rotor part rotate fl e xibl y...