Safe Notice This product has good and reliable performance within the use scope of the design, but However, artificial damage to the device should be avoided. Before using the device, please read the manual carefully to ensure the safety of the users and the device. Please keep this manual properly for future reference.
Page 4
The device shall be scrapped in accordance with the relevant national regulations to reduce the environmental pollution. In the following cases, please immediately disconnect the power supply and contact us. The water enters into device. Device breakdown or casing break. ...
Product Overview 1 Product Overview KOM-DH DIN rail chassis supports 4 slots, up to 4 KOM600H 100M or 1000M media converters, flexible configuration, and supports redundant power input of 100-240VAC, 50/60Hz, 110-220VDC. 1.1 Front panel Figure 1 KOM-DH front panel view...
Product Overview 1.2 Side panel Figure 2 KOM-DH Side panel view 1.3 Matched media converter models 100M media converter Support 1 100M ethernet port and 1 100M singlemode SFP port 12VDC KOM600H-100/SM-12VDC single power input. support 1 100M ethernet port and 1 100M multimode SFP port, 12VDC KOM600H-100/MM-12VDC single power input.
Installation 2 Installation 2.1 Dimensions Figure 3 Dimensions (mm) Caution: The device enclosure is a part of the cooling system of the whole device. The enclosure will heat up at the normal working. Do not cover the enclosure when the device is working. 2.2 Installation methods and steps Before installing, please confirm the following installation requirements: 1)Environmental requirements: temperature -20℃~70℃, relative humidity 5%~95% (no...
Installation 7) Only professionals, or trained and qualified personnel can install, replace, and repair this device. 2.2.1 Chassis installation and disassemble Installation Step 1:Select the installation location of the device to ensure enough installation space and smooth heat dissipation. Step 2:Put the upper part of the rail socket on the DIN rail, push slightly up at the lower end of the device, follow the arrow 2 below to turn the device, until the device is reliably installed on the DIN rail to complete the installation.
Installation Figure 5 Disassemble from rail 2.2.2 Media converter installation and disassemble Installation Select the installation location of the device to ensure enough installation space and smooth heat dissipation. Step 1:insert the KOM600H media converter into the selected chassis and push the device in the direction of arrow 1 till the 12VDC power terminal of the device back panel is inserted.
Installation Step 2, remove the device from the chassis and complete the disassembly. 2.2.3 Grounding Normal grounding of device is an important guarantee for lightning protection and interference prevention of device, so users must connect the grounding wire correctly. And ground before power on, and then disconnect the grounding wire after power off.
Page 12
Installation Figure 7 5-pin 5.08mm spacing plug type terminal (Socket) Table 2 5-pin 5.08mm spacing plug type terminal definition PIN No. Signal AC wiring definition AC wiring definition PGND PGND PWR1:+ PWR1:L PWR1:- PWR1:N PWR2:+ PWR2:L PWR2:- PWR2:N Wiring and installation Step 1, ground the device well follow step 2.2.3.
Page 13
Installation Wiring cross-sectional Terminal type Torque requirements area range (AWG) Plug-in terminal 4.5-5.0 lb-in 12-24 Caution: Before connecting to the power supply, check that the power supply meets the requirements identified by the device to avoid damage to the device. Warning:...
LED status 3 LED status Table 4 Front panel LED description Status Description The input power 1 is connected correctly and running normally PWR1 LED The input power 1 is not connected or is running incorrectly The input power 2 is connected correctly and running normally PWR 2 LED The input power 2 is not connected or is running incorrectly...
Basic performance and specifications 4 Basic performance and specifications Slot Slot number Power LED PWR1,PWR2 Power supply Input voltage range 100-240VAC,50/60Hz,110-220VDC redundant power input Terminal 5-pin 5.08mm spacing plug-in terminal Power rating 9.5W Mechanical Chassis Metal, no fan Mounting DIN rail Dimension 87.6mm×142mm×139mm(Excludes the connector overhang, and (W×H×D)
Page 16
Basic performance and specifications IEC61000-4-5(Surge): Power Port: ±1kV/DM, ±2kV/CM; Data Port: ±1kV IEC61000-4-6(CS): 10V (150kHz–80MHz) Safety IEC62368-1, EN62368-1 Warranty warranty 5 years...