Legendfires Ethos 400 Installation And User Instructions Manual

Advertisement

Quick Links

Ethos 400 Stove
- Log Effect
- Live Fuel Effect Radiant Convector Stove
Installation and
Users Instructions
These instructions should be read by the
installer before installation and then should be
handed to the end user when the installation
is complete.
This is an official requirement and is the
responsibility of the fitter of this
appliance.
Having installed the appliance, the installer
should take the necessary steps to ensure
that the user fully understands how to operate
the appliance and is also made aware of the
fire's basic cleaning and maintenance
requirements.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ethos 400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Legendfires Ethos 400

  • Page 1 Ethos 400 Stove - Log Effect - Live Fuel Effect Radiant Convector Stove Installation and Users Instructions These instructions should be read by the installer before installation and then should be handed to the end user when the installation is complete.
  • Page 2: Table Of Contents

    CONTENTS SECTION pagE Notes for the Installer and End User Installation Requirements Installation Procedure Installation - Class One Flue Commissioning Technical Data Replacement Parts Trouble Shooting (GAS SAFE Engineer Only) User Instructions Cleaning and Maintenance Log Layout Instructions Trouble Shooting (User) Guarantee...
  • Page 3: Notes For The Installer And End User

    NOTES FOR ThE INSTaLLER aND END USER This appliance has been designed, tested and manufactured to EN613 and must be installed by a qualified Gas Safe Registered Installer in accordance with the Gas Safety (Installation and use) regulations 1994 and all other relevant standards.
  • Page 4 NOTES FOR ThE INSTaLLER aND END USER This fire is a very effective heating appliance and must be fitted against a wall of non-combustible material as classified in BS 476-4:1970 (2007). All parts of the appliance become hot while running and should therefore be considered to be working surfaces. An air vent is not required for this application.
  • Page 5: Installation Requirements

    INSTaLLaTION REqUIREMENTS This appliance must only be installed in great Britain or Ireland. 1. This fire is a natural gas appliance and has been designed for use with the following applications: a) Class I - Conventional brick or stone chimney as used for a solid fuel fire with a cross sectional dimension of 225mm x 225mm (9”...
  • Page 6: Installation Procedure

    INSTaLLaTION pROCEDURE 1. Remove the magnetic trim from the front of the stove (Fig. 2). 2. Remove the two screws at the bottom of the glass door panel (Fig. 3). Magnetic Trim 3. Hinge the door upwards by approximately 30° (Fig.
  • Page 7: Installation - Class One Flue

    INSTaLLaTION - Class One Flue with Flexible Liner This appliance should be installed in accordance with BS5871-2: 2005. A debris collection space is not required for a lined chimney. This liner has to be fitted to the top of the appliance via the stove pipe and extend all the way to the top of the chimney capping and terminated by a BS Gas Flue Terminal.
  • Page 8: Commissioning

    COMMISSIONINg 1. Remove the burner assembly (2 x wing nuts) and chosen gas inlet plate (Fig. 8). M5 Machine Screws Burner Assembly 2. Relocate the burner assembly and mark/cut gas pipe to length, then secure burner assembly with the 2 x M5 Fig.
  • Page 9 COMMISSIONINg 5. Refit all the back and side liner components and slide black top panel back into position (Fig. 11). 6. At this stage locate the burner top grille on the tabs provided before slotting the remaining liner blocks into position.
  • Page 10: Technical Data

    TEChNICaL DaTa Model Ethos 400 Stove Gas Type Natural Gas Gas Category Gas Type Inlet Pressure (mbar) Countries of Destination See table below Gas Valve TESC-01 RF868-30 Injector Size Bray 82/360 Oxypilot ERTA PG-82-650 Gas Rate Full Reduced Nominal Heat Input (Gross, kW) Nominal Gas Flow Rate (m3/h) 0.524...
  • Page 11 TROUBLE ShOOTINg (gaS SaFE ENgINEER ONLY) Code Comment Apperance Possible Cause Action TESC locked due to Red Led is Temporary air Reset control by pressing start button for 1 second and releasing. Then press again the same way failed ignition permanently on disturbance around pilot to attempt a normal start command.
  • Page 12 TROUBLE ShOOTINg (gaS SaFE ENgINEER ONLY) Code Comment Apperance Possible Cause Action Button (-) is shorted Check for contamination Clean as necessary. Replace switch panel as necessary if damaged or too contaminated. Reset and try again to other buttons / damage and replace disconnect wired control panel and try again –...
  • Page 13: User Instructions

    USERS INSTRUCTIONS warnings all parts of the appliance become hot while running and should therefore be considered to be working surfaces. a suitable guard may be required to take account of special hazards that exist in nurseries and other places where there are young children, aged or infirm persons. Curtains are not to be placed directly above the appliance.
  • Page 14 USERS INSTRUCTIONS handset Ensure the Power Isolator Switch on the front corner of Fire Control is in the on position (I). Note: For safety reasons a button must be pressed and released for the command to be recognised. Keeping hold of the button when pressing (unless otherwise instructed) will not be recognised as a command press. Grasp around the handset to unlock its functions.
  • Page 15 USERS INSTRUCTIONS Operating instruction (Detailed) ThE haNDSET aND CONTROLS ShOULD aLREaDY BE paIRED aND ThE DaY aND TIME SET CORRECTLY. ShOULD aNY aDJUSTMENTS BE NECESSaRY SEE INSTRUCTIONS BELOw: Setting the time Following pressing “SET” at paring above, the display will be as shown, as the time is not set yet and will progress automatically to the next screen shown below.
  • Page 16 USERS INSTRUCTIONS paging the handset If you have misplaced the handset you can page it by pressing the + button only on the fire control for around 5 seconds. The handset will flash and make a noise to help you to locate it. Once you pick up the TESC it knows you hold it and so the sound stops.
  • Page 17 USERS INSTRUCTIONS Snooze mode in Thermostatic mode The same thing as above can be done before or during a thermostatic mode operation (see below). Thermostatic mode only The handset has within it a thermostat sensor and this can be set so the fire will heat the room to match the temperature set in the handset.
  • Page 18: Cleaning And Maintenance

    CLEaNINg aND MaINTENaNCE It is recommended that this appliance is serviced at regular 12 monthly intervals. The chimney or flue should also be checked regularly to ensure that all products of combustion are entering the flue and there is no excessive build up of soot.
  • Page 19: Log Layout Instructions

    LOg LaYOUT INSTRUCTIONS CaUTION: The logs are extremely fragile and must be handled accordingly. gloves should be worn and any inhalation of dust should be avoided. The logs must be kept away from children at all times. Never put additional logs on the fire. Never use logs other than those originally supplied, or genuine Legend Spare parts.
  • Page 20 LOg LaYOUT INSTRUCTIONS CONTINUED 9. Place the remaining logs as shown in the photographs below.
  • Page 21 LOg LaYOUT INSTRUCTIONS CONTINUED It is very important that all the logs are used and arranged as shown in order to achieve the desired flame picture. It may be necessary to remove some or all of the logs to clean them at some time. Cleaning must only be done using a soft brush.
  • Page 24: Trouble Shooting (User)

    TROUBLE ShOOTINg (USER) Non Display handset with pilot burner If the fire does not start at the first attempt it may retry several times to do so. At the end of trying if it cannot ignite the burner; it will show a RED light on the handset and on the fire control and stop the fire. •...
  • Page 25 Check out our full range of Heating Products Central Heating Controls Honeywell Heating Controls Danfoss Heating Controls Radiator Valves Fernox Sentinel Magnaclean Warmup underfloor heating Water Heaters Hand Dryers...

Table of Contents