FM PREMIUM 25 kW Brief Instructions For Commissioning

Advertisement

Quick Links

INSTRUCTIONS FOR COMMISSIONING
and use
Pellet stove
FM PREMIUM 25 kW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PREMIUM 25 kW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FM PREMIUM 25 kW

  • Page 1 INSTRUCTIONS FOR COMMISSIONING and use Pellet stove FM PREMIUM 25 kW...
  • Page 2 ATTENTION! STRICTLY OBSERVE! ATTENTION!!! Installation, installation and commissioning of a thermal fireplace should be carried out by an authorized service or an authorized specialist, observing safety instructions and labor rules. ATTENTION!!! Do not connect the exhaust system to a chimney to which another fireplace, boiler or suction system is already connected.
  • Page 3: Table Of Contents

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 1. Precautionary measures ................... 4 2. Technical specifications ..................... 6 2.1. Supply and unpacking of the thermofireplace 2.2. Description of the pellet fireplace 2.3. Technical specifications 3. Installation of a pellet fireplace ..................8 3.1.
  • Page 4: Precautionary Measures

    1. Precautionary measures The FM PREMIUM 25kw pellet fireplace is designed to have maximum safety and ease of operation. However, it is necessary to observe the following safety measures: 1. The authorized installer is advised not to leave uncovered parts of pipes that are not fully enclosed in the collector.
  • Page 5 INSTRUCTIONS FOR USE FM PREMIUM 25KW For safe operation, it is necessary to strictly adhere to the following rules: - The pellet stove should not be operated by children or disabled people. - It is forbidden to install a fireplace in wet or damp rooms, for example, in a bathroom or a room intended for a washing machine.
  • Page 6: Technical Specifications

    Carefully read all documentation and save it. If a defect, damage or missing parts and elements are found, contact the seller from whom you purchased the product. 2.2. Description of the pellet fireplace Termosemineul or plate FM PREMIUM 25kW with water jacket, is designed connection heat installation, heating houses, offices, smaller restaurants and others.
  • Page 7: Technical Specifications

    INSTRUCTIONS FOR USE FM PREMIUM 25KW Elements of a pellet furnace: 1 - Command (Controller) 6 - Ash drawer 2 – Pellet tank cap 7 - Torch 3 – Pellet tank 8 - Power supply 4 - Heat-resistant glass 9 - Side decorative panels...
  • Page 8: Installation Of A Pellet Fireplace

    INSTRUCTIONS FOR USE FM PREMIUM 25KW at 13 % oxygen O₂ at rated heat capacity Efficacy Power of the electrical part Voltage V/Hz Recommended fuel Lem granules, Diameter 6-8 mm, EN 14961-2:2011 The data in the table above form the basis for tests carried out on the combustion of wood pellets with a calorific value of 18220 Kj/kg (equivalent to 4350 Kcal/kg).
  • Page 9: Connection Of The External Fresh Air Intake Pipe

    INSTRUCTIONS FOR USE FM PREMIUM 25KW ABOVE recommendations for the installation and installation of a thermal fireplace: Check the minimum volume of the room in which the thermofireplace will be installed (not less than 40 m3 ); Check if there is an open place where smoke can escape;...
  • Page 10: Flue Gas System

    INSTRUCTIONS FOR USE FM PREMIUM 25KW EXAMPLE OF AN OUTDOOR CONNECTION (fresh air intake) For proper operation, an external connection can be made through a pipe with a diameter of 80 mm, with a silicone gasket. The outer opening should be facing downwards and the pipe angle should be 90° –...
  • Page 11: Flue Gas System Pipes (Chimney Connection Pipes)

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 3.5. Flue gas system pipes (chimney connection pipes) Pipes must be strong, fine inside, machined from metal and silicone gaskets. The diameter of the pipes up to 3 m long should be 80 mm.
  • Page 12 INSTRUCTIONS FOR USE FM PREMIUM 25KW ✓ To make the connection of a thermofireplace / stove to the chimney, we recommend that you call or consult a specialist. The connecting elements (elbows, gutters) must be fastened tightly, durable in order to avoid the escape of smoke and so as not to disturb the passage part of the chimney.
  • Page 13 INSTRUCTIONS FOR USE FM PREMIUM 25KW The chimney must be built in accordance with the current norms in accordance with STAS 6793 and STAS 3417 for authorized personnel. Schemes for connecting a flue gas system / connecting a thermofireplace to a chimney / .
  • Page 14 INSTRUCTIONS FOR USE FM PREMIUM 25KW...
  • Page 15: Connection To Electrical Wiring

    INSTRUCTIONS FOR USE FM PREMIUM 25KW Flue gas discharge problems For all the problems associated with the evacuation of burnt gases, the wind plays the greatest role. 3.7. Connection to electrical wiring After installation in the room, the thermofireplace must be connected to the power supply network.
  • Page 16: Combustible Mixture

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 4. Combustible mixture ATTENTION! Pellet fireplace is tested only with wood pellets with a diameter of 6÷8mm, EN plus class A1, according to EN 14961:2011. The manufacturer is not responsible for malfunctions if you use fuel that he does not recommend.
  • Page 17 INSTRUCTIONS FOR USE FM PREMIUM 25KW Table: European wood pellet certificate Parameters Measures ENplus-A1 ENplus-A2 EN-B Diameter 6 (± 1) 6 (± 1) (± 1) 8 (± 1) 8 (± 1) (± 1) Length 15 ≤ L ≤ 40 1) 15 ≤...
  • Page 18 INSTRUCTIONS FOR USE FM PREMIUM 25KW When purchasing pellets, request a declaration of conformity and a certificate from an accredited laboratory, make sure that the fuel meets the requirements specified in the instruction. When purchasing a large number of pellets (for example, the amount required for the heating season), ask the supplier for specific and accurate information on how to store the pellets.
  • Page 19: Operation Of A Pellet Fireplace

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 5. Operation of a pellet fireplace Attention! This is done by an authorized service / installer! 5.1. Safety measures when operating pellet fireplaces The thermofireplace develops a very high temperature, and when touching hot surfaces there is a risk of burning.
  • Page 20: Controller / Cod Psysq 01000013

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6. Controller / cod PSYSQ 01000013/ 6.1. Description "EasyTech.One" is an order for pellet, water and dry fireplaces. Main features: Easy to install and use; Secure and flexible software; Clear and specific features for the user;...
  • Page 21: Connection

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.2. Connection...
  • Page 22 INSTRUCTIONS FOR USE FM PREMIUM 25KW FUNCTION CHARACTERISTICS 230 Vac ± 10% 50/60 Hz Feeding F1 = fuse T5,0 A Electric relay - maximum load 1А Electric relay - maximum load Pump 1А Heater Relay 3A МАХ Electric relay - maximum load Top-rail motor 1А...
  • Page 23: Control Panel. Functions

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.3. Control Panel. Functions -1- Display Fixed / permanent indication Blinking indication Stabilization phase Ignition phase Fireplace suspension Deletion phase Operating mode Modulation phase Engine screen turned on Heater on Programmer on Pump on...
  • Page 24 INSTRUCTIONS FOR USE FM PREMIUM 25KW -3- Alarms Description Error code HV1 protection thermostat: transmits Block Er 01 the signal and when fireplace is OFF Block Er 02 HV2 pressure protection thermostat: sends a signal when the fan is turned...
  • Page 25: User Menu

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.4. User menu (1) 6.4.1. Ignition/extinguishing P1 button saving activates ignition and extinction. Ignition is indicated by LEDs flashing first then remain permanent - L1. The operating mode is signaled by light Lead Permanent L4.
  • Page 26 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.4.4. Manual pellet feed Holding down the P2 button activates a manual pellet feed. At the bottom of the display is indicated the current mode. At the top, specify the previous feeding mode. To stop, press any button that it is.
  • Page 27 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.4.7. Display It is activated by pressing the P1 button. tA = chamber temperature tF = flue gas temperature UF = fan speed [RPM/Volt] HF02+ Commodity Code...
  • Page 28: User Menu

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.4.8. Remote control Button 1 (blue) activates the deletion. Button 2 (red) activates the ignition. Buttons 3 (yellow) / 4 (yellow) reduce / increase the degree of burning. Code modification: Remote control: Open the battery compartment cover.
  • Page 29 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.5.2. Chrono function Turn the system on/off -1- Start Schedule setting. Press the P2 button to open the menu. Press the P3/P4 buttons to see the option: ON = the beginning of programming; OFF = Discontinuation of programming.
  • Page 30 INSTRUCTIONS FOR USE FM PREMIUM 25KW Hold the P1 button: on / off for the selected period of time. Appointm - Set the selected time one day in advance to ON, at the desired value: for example, 20.30 - - Set the time to OFF, one day in advance, at 10:30 a.m.
  • Page 31: Mode Of Operation

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.6. Mode of operation 6.6.1. Off Timer Team Screw Heater if temp. the amount → Enter DELETE of combustion gases (STINGER) mode is > Th01 TORN OFF TURN OFF TURN OFF if temp. water is >...
  • Page 32 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.6.7. Stabilisation Timer Team Screw Heater if temp. the amount → Enter NORMAL of combustion gases mode is > Th09 if temp. the → repeat again amount of Ignition (Ignition) combustion gases → Enter the STOP is >...
  • Page 33 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.6.9. Regim normal (normal) Parameter Command Protractor Heater if temp. the amount of → Launches the T14 combustion gases is timer for pre-deletion in standby mode > Th03 Thermostat or if the Command combustion gas temperature after T14 is <...
  • Page 34 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.6.10. Modulation Parameters Team Protractor Heater If temp. the → Timer T14 number of starts for combustion gases pre-deletion is < Th03 in standby T14 T14 Thermostat or, if mode temp. gas control combustion is <...
  • Page 35 INSTRUCTIONS FOR USE FM PREMIUM 25KW T16 Cleaning If temp. combustion gases → The timer T16 Full speed < Th01 Thermostat starts → Enter OFF error-free T16 control → Enter Block with possible errors 6.6.12. Block Team Protractor Heater To exit: Press the P1 button for 3 seconds If there are no other locking conditions →...
  • Page 36: Functions

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.7. Functions 6.7.1. Modem control (not included in the basic package) The team manages the modem's communication with the fireplace via SMS for ignition, extinguishing, status operations, and provides information when an alarm occurs. The modem connects to the command via RS232. It is supplied with a power cord.
  • Page 37 INSTRUCTIONS FOR USE FM PREMIUM 25KW Status The modem sends back an SMS message to the number from which it (Statutes) received an order with a status or error code. To learn The fireplace has memorized the number from which the...
  • Page 38 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.7.5. Automatic control of combustion power steps To set the combustion, the user can set: AUTOMATIC METHOD [A] The combustion rate is automatically set depending on the water temperature and the parameter set for the thermostat: •...
  • Page 39 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.7.7. Fan control correction The user can adjust the fan speed in the range: -7 ÷ 7 P16 is the percentage of the change value. U03=1000 U03=1000 U03=1000 U04=1200 U05=1400 U06=1600 U07=1800 U11=900 U03=1150 U03=1150 U03=1150 U04=1380 U05=1610 U06=1840 U07=2070 U11=1035 The values determined are between: P14 ÷...
  • Page 40 INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.7.9. Configuring the pressure sensor setting The user can correct the start time of the auger in steps: – 7 ÷ 7 1- voltage (volts); 2 – Pressure (mbar)
  • Page 41: Cleaning And Maintenance

    INSTRUCTIONS FOR USE FM PREMIUM 25KW 6.7.10. Installation control Example: P26=0 Th18= 5 °C Th19= 50°C Th21= 80°C P26=1 Th18= 5 °C Th19= 40 °C Th21= 80 °C Th47= 8 °C 7. Cleaning and maintenance Regularly clean the pellet fireplace and flue gas system.
  • Page 42 INSTRUCTIONS FOR USE FM PREMIUM 25KW Clean the burner daily. Every month, clean the pellet tank, remove sawdust deposits. Clean the fireplace thoroughly after burning 800 to 1,000 pounds of pellets or do it at least once a year. ATTENTION! When cleaning a thermofireplace, observe the following steps: •...
  • Page 43 INSTRUCTIONS FOR USE FM PREMIUM 25KW Checking / replacing the door cord of a thermofireplace The wire guarantees an airtight closing of the door and the correct operation of the pellet fireplace. Regularly check the condition of the cord. If you notice a malfunction, contact the authorized service to replace the wire with a new one.
  • Page 44 INSTRUCTIONS FOR USE FM PREMIUM 25KW If the holes in the burner are filled with impurities, it must be opened and cleaned. Cleaning the pellet tank It is recommended to clean the tank period (at least once a month). Cleaning is carried out in this way: empty the pellet tank, then clean it with the help of a vacuum cleaner.
  • Page 45 INSTRUCTIONS FOR USE FM PREMIUM 25KW 1) dismantling the cover of smoke pipes; 2) Cleaning the precipitated tar with a wire brush 3) cleaning tar from smoke pipes through an inspection hole on both sides of the fireplace. After cleaning, close the system. After using poor-quality granules, we recommend that you do this cleaning once a month.
  • Page 46: Service

    INSTRUCTIONS FOR USE FM PREMIUM 25KW Inspection and cleaning of the flue gas exhaust system At the beginning of each cold season, the flue gas exhaust system must be cleaned. If the electrical cable has failed, it must be replaced.

Table of Contents