USER GUIDE
EVX100
EV charger interface for the MFT-X1
Register
Support
User Guide
megger.com/register
megger.com/support
EN
ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVX100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Megger EVX100

  • Page 1 Acutest Direct USER GUIDE EVX100 EV charger interface for the MFT-X1   Register Support  User Guide megger.com/register megger.com/support ENGLISH...
  • Page 2 Megger Limited, Archcliffe Road, Dover, Kent CT17 9EN. ENGLAND T +44 (0)1304 502101 F +44 (0)1304 207342 www.megger.com Megger Ltd reserves the right to alter the specification of its products from time to time without notice. Although every effort is made to ensure the accuracy of the information contained within this document it is not warranted or represented by Megger Ltd.
  • Page 3 Other equipment manufactured by Megger Instruments Limited described in this user guide is in compliance with Directives 2014/30/EU and 2014/35/EU where they apply. The full text of Megger Instruments EU declarations of conformity are available at the following internet address: megger.com/eu-dofc...
  • Page 4: Table Of Contents

    5. Testing the EV charger ....................11 Connecting the EVX adaptor and power ON/OFF ..............11 MFT-X1 connection errors ......................12 Manual battery status check on the EVX100 ................12 6. Testing with the EVX ......................13 Testing for live voltages across terminals .................. 13 Phase sequence ...........................
  • Page 5: Introduction

    This user guide describes the operation and functions of the EVX100 Electric Vehicle Charge point Adaptor when used with the MFT-X1 multi-function tester to test EVSE units (Electric Vehicle Supply Equipment).
  • Page 6: Safety Warnings And Standards

    Plug in the EVX to the MFT before connecting to the EVSE to be tested. Similarly, „ disconnect from the EVSE before unplugging the EVX and MFT. „ Do not connect USB cable when EVX is connected to EVSE. Use only Megger approved adapters with this product. „ www.megger.com EVX100...
  • Page 7: Installation Category Definitions

    Safety Warnings and Standards „ No user serviceable parts are inside the equipment. Refer repairs to Megger approved service centres. „ This equipment contains a lithium-ion battery. Do not heat or dispose of the product in a fire. At the end of the equipment’s life dispose of it according to local regulations for „...
  • Page 8: Instrument Overview

    The following list explains the EV charger status codes reported by the MFT-X1 when using the EVX100. Most of these codes will only appear momentarily during a tripping test sequence. For normal operation with the MFT-X1 switched on and the EVX100 connected to a working charger the EV charger will be in state C2.
  • Page 9: Operation

    Operation 4. Operation NOTE : The EVX100 MUST be charged before use else the unit will not operate.This is required as international shipping prevents Li-ion battery operated equipment being shipped with more than 30% charge. Designed for testing Mode 3 AC electric vehicles, the Electric Vehicle Charge-point Adaptor, EVX100, is a compact and portable unit, designed to be fitted directly to the front of the MFT-X1.
  • Page 10: Battery Status And Charging

    Holding down the button on the top of the EVX100 will also show battery status. Charging the EVX100 NOTE : The EVX100 will only charge over an ambient temperature range of 0 ºC to 45 ºC. Charging the EVX100 battery status is performed using a type C USB cable.
  • Page 11: Testing The Ev Charger

    Do not force the adaptor, but be aware that it is a snug fit. 2. Connect the EVX connector plug to the EV charger. The EVX100 is now ready to establish communications with the EV Charger. 3. Turn the left rotary dial on the MFT-X1 to the Voltage setting.
  • Page 12: Mft-X1 Connection Errors

    (State C). MFT-X1 connection errors After switching on the MFT-X1 the EVX100 LED continues to rapidly flash Yellow for more than 30seconds, the EVX has not established connection to the MFT.
  • Page 13: Testing With The Evx

    Once in the disabled state, the charger is sent a state A, B and C to set it back to a charging state. To test the PE or CP error response: 1. Ensure the MFT-X1, and EVX100 are in voltage mode and the MFT is displaying State C2. 2. Press the Hot key 1 to select PE or CP error.
  • Page 14: Testing For Pe Earthing Issues

    Loop impedance is tested in the same way as on the standard MFT-X1 without the EVX adaptor. For full details of loop impedance testing refer the full MFT-X1 user manual. The EVX100 limits functionality to those tests suitable for use on an EV charger, as below: www.megger.com...
  • Page 15: Hot Key Options Available With The Evx100

    Testing with the EVX Hot key options available with the EVX100: Hot key options available are: Hot key 1: Shows the loop impedance value for the connection selected on hot key 5 Zmax: Shows the latest loop impedance value and also the highest value...
  • Page 16: Running A Loop Impedance Test

    NOTE : Both of these warnings will inhibit the MFT-X1 from performing a loop measurement. NOTE : The L-N swapped warning and inhibit can be disabled in SETTINGS for the MFT-X1. www.megger.com EVX100...
  • Page 17: Testing Rcd And Rdc Functionality

    Image loop test on L-PE Should an RCD or RDC trip during the measurement mode, the EV charger will lose power and switch off. The EVX100 will automatically attempt to reset the EV charger by sending the Status sequence: C, B, A, B, C.
  • Page 18: Testing The Rcd/Rdc

    Testing with the EVX Testing the RCD/RDC The EVX100 offers automatic test sequences for RCD and RDC testing. If only a part of the sequence needs to be run, the AUTO sequence can be modified in SETTINGS RCD tab – refer to the full MFT-X1 user manual.
  • Page 19: Specifications

    For measurement specification refer to the MFT-X1 user guide. See megger.com/mft-x1 NOTE : Uses the Megger Confidence Meter to measure the supply source impedance of circuits protected with an RCD rated ≥30 mA when there are only two connections possible. When a neutral is available the three-wire test will provide a quicker, more accurate result.
  • Page 20: Accessories

    Refer to www.megger.com/support Cleaning Should the EVX100 or the charge plug or cable require cleaning they can be wiped down using a damp cloth. Never clean the adaptor or plug when connected to any measurement circuit.
  • Page 21: Repair And Warranty

    3. Pack the instrument carefully to prevent damage in transit. 4. Before the instrument is sent to Megger, freight paid, make sure that the returns label is attached or that the RA number is clearly marked on the outside of the package and on any correspondence.
  • Page 22: Weee Directive

    Megger is registered in the UK as a Producer of Electrical and Electronic equipment. The registration No is; WEE/DJ2235XR. Users of Megger products in the UK may dispose of them at the end of their useful life by contacting B2B Compliance at www.b2bcompliance.org.uk or by telephone on 01691 676124.
  • Page 23 ■ Multiple user access (licence required per user) ■ Electrical, fire, lighting, PV, EV certificates ■ Attach photographs to bespoke certificates 30 Day FREE Trial Visit Certsuite.info for more information at CertSuite.info Or scan the QR code ➔ www.megger.com EVX100...
  • Page 24 The company reserves the right to change the specification or design without prior notice. Megger is a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, ® Inc and is used under licence. www.megger.com EVX100_2017-287_UG_EN_V04 The word ‘Megger’ is a registered trademark. Copyright © 2024...