Page 1
USER MANUAL COMMERCIAL CHEST FREEZER MODEL: CF30, CF44, CF60, CF76 USR Brands, Inc. Phone: 800-764-1172 | www.usrestaurant.com | sales@usrestaurant.com USRESTAURANT® RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE...
Page 2
Dear Consumers: Thank you very much for purchasing our products. In order to ensure your safety and achieve the best out of this freezer, please read this instruction carefully. Please read this user’s manual thoroughly before using. Keep this manual handy for further reference. General ...
The appliance is to be installed in accordance with the Safety WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.The appliance shall be stored in a room without continuously operating ignition sources(for example: open flames, an operating gas appliance or an operating electric heater.
Page 4
should be padded well so as to make the freezer be level and stable, or it will cause vibration and too much noise. 3. If power is cut off, wait at least 5 minutes before turning on again to avoid damage to the compressor.
DANGER: Risk of fire or explosion. Flammable refrigerant R290/R600a used. To be repaired only by trained service personnel. Do not use mechanical devices to defrost refrigerator. Do not puncture refrigerant tubing. ATTENTION: pour assurer la sécurité, la fiche d'alimentation doit être retirée avant le nettoyage.
For foods that should be moisture-free or lose water easily, wrap them up with hermetical food bags or fresh films before putting in the cabinet for the sake of avoiding smell-mixing and reducing frosting. Storage of volatile and combustible gases, liquids such as strongalkalies, strong acids, petrol ,etc.
Page 7
technician is aware of potentially toxic or flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants, i.e., non-sparking, adequately sealed, or intrinsically safe. Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
Trouble Shooting Breakdown Case Removal method The plug isn’t connected to Replug it. The indicator is not on. socket really. The compressor doses not start. Connect the socket with no power power. The indicator is on, but the The power voltage is<98V. compressor doesn’t work and buzzes only Put a power-regulator...
Need help?
Do you have a question about the CF30 and is the answer not in the manual?
Questions and answers