YUEQING,WENZHOU,ZHEJIANG 325603,CHINA TEL : +86-577-5717 7008 Email : benyi@zjbeny.com VERSION : 20240820 For the latest version of specification, please refer to www.beny.com or contact to benyi@zjbeny.com We reserve the right to explain the terms of specification. Importer Information Importer: XXXXXXX...
Page 2
SAVE THESE INSTRUCTIONS-This manual contains important instructions for ZBENY Rapid Shutdown Ststem Equipment that shall be followed during installation and maintenance of the Rapid Shutdown Ststem Equipment,BFS-A1,BFS-ESW11,BFS-ESW12,BFS-ESW21,BFS-ESW21-K,BFS-ESW11-K,BFS-ESW12-K. No part of this publication may be stored, reproduced or copied without prior written permission from ZJBENY. The material furnished in this document is believed to be accurate and reliable however, ZJBENY assumes no responsibility for the use of this material.
Page 3
The ZJBEN BFS product is Rapid Shut Down Equipment for connecion to PV panel arrays in order to achieve compliance to 2014 NEC 690.12 and 2017 NEC 690.12. The BFS automatically shuts down array output to the PV inverter when it detects a temperature in excess to 100℃(BFS-A1).
Page 5
BFS-A1 INSTALLATION DIAGRAM One BFS-A1 will control two solar panels and by series connection of the BFS, multiple solar panels can be connected to from a greater capacity system. The diagram below illustrates a typical example of a BFS protected installation using six solar panels and three BFS-A1.
Page 6
*Water resistant end stop - Insert the two red sealing plugs in to the Communication Superseal plug(supplied) and connect to the DC output connector of the last BFS-A1 in the series in stallation.If only a single BFS-A1 is used then this patr is still used to seal the DC output connector.
Page 7
Installation Manual BFS-A1 MULTI-STRING INSTALLATION DIAGRAM(Even number per string) 110V input 110V input 110V input 110V input OUT- OUT+ OUT IN OUT- OUT+ OUT IN OUT- OUT+ OUT IN OUT- OUT+ OUT IN 110V input 110V input 110V input 110V input...
Page 8
* Please refer to the open circuit voltage (Voc) and the short circuit current (lsc) of the PV module. 0.823mm / 18AWG 0.5-4mm / AWG 26-10(Note: use communication connector 2*0.823mm ) Maximum BFS-A1 Units 40 Units / 150M 90 Units / 150M...
PV array Negative (-) goes to BFS-A1 Negative (-) No BFS-A1 output Replace BFS-A1 Check BFS-A1 output connections Check all PV array Positive (+) go to BFS-A1 Positive (+) Incorrect BFS-A1 polarity connection and PV array Negative (-) go to BFS-A1 Negative (-) MAINTENANCE INSTRUCTION 1、Check the string voltage and string current weekly to ensure that the circuit formed by the overall photovoltaic panel is on...
Need help?
Do you have a question about the BFS-A1 and is the answer not in the manual?
Questions and answers