Table of Contents INTRODUCTION EATURES OMPONENT DDITIONAL CCESSORIES FIRMWARE AND SOFTWARE IRMWARE ESSION SOFTWARE UDIO ILES PANEL OVERVIEW OWER ANEL UTTONS NPUTS ACKS AND ORTS LED DISPLAY ESSION CREEN SELECTING A SESSION ESSION YPES CES S ESSION ATEGORIES AVE S ESSION ESCRIPTIONS CES S...
Page 4
EYESET COLORS SESSION SETTING SCREENS ESSION ONTROLS ESSION REFERENCES PERATING A ESSION ESSION IEWS ESSION REFERENCES BEFORE YOU BEGIN AN AVE SESSION LIVE SESSION ESSION ETTINGS YSTEM ETTINGS WARRANTY AND CARE ARRANTY ETURNING FOR REPAIRS ARE AND AINTENANCE COMPLIANCES FCC C OMPLIANCE TATEMENT ISED C...
Stimulation (CES) experiences. Extra kits for Microcurrent Electro Therapy (MET) and Transcranial DC Stimulation (tDCS) are available for purchase. The portability of the DAVID Premier lends itself to easy travel (airport x-ray machines will not harm the DAVID Premier). The DAVID Premier incorporates advanced dual-hemisphere AVE as well as Randomized AVE (RAVE).
PANEL OVERVIEW OWER Before you begin a session, check the battery level on the screen. The Power LED has three colors: Solid Green: fully charged. Flashing Yellow: While your Premier is charging, the power light will flash yellow. It will become green once fully charged.
ANEL UTTONS Press and hold to turn the device on or off. Press to perform the action shown in the bottom-left corner of the screen. Press and hold to perform a special action on the current screen. Press to perform the action shown in the bottom-right corner of the screen. Press to adjust the audio volume during AVE sessions.
LED DISPLAY When you power up your Premier for the first time, you may choose from Session Library, Live Session or System Settings. Once you have selected a session, Recently Played Sessions will be shown. o Press to scroll between menu options. o Press to select a menu option.
Page 10
All of your session information is shown on the display. Below is an explanation of the icons: 1) AVE Relaxation – Shows the type of stimulation (AVE, RAVE, CES, MET, tDCS) and category. In this example, we have selected AVE stimulation in the Relaxation category. Push and hold the for CES stimulation.
SELECTING A SESSION ESSION YPES This table shows the various types of stimulation on a fully loaded Premier. Audio-Visual Entrainment. Cranio-Electro Stimulation (short pulse) Cranio-Electro Stimulation with 50% duty cycle (long pulse). This is a much stronger form of standard CES.
Page 12
Sessions to wake you up and stimulate you for an energetic morning. These are in the 19 - 23 Hz range. Energize Sessions using Eye Movement Desensitization and Restabilization technique. EMDR Sessions help increase myelin, cerebral spinal fluid, and amyloid plaques. These sessions are used to help with cognition and brain function all around.
AVE S ESSION ESCRIPTIONS All of the AVE sessions (except Ganzfeld) also include CES to assist with relaxation by increasing endorphins and serotonin. After 20 years of observation, we have concluded that mild randomization (±1Hz) is more effective than a fixed frequency which we call RAVE (Randomized Audio-Visual Entrainment).
Page 14
Paradise - 40 min – 6.5 Hz Developed in the 1990s, this is a favourite for those wanting a deep, relaxed state of mind. A gentle slide down from alpha to theta. Extroverts with low anxiety produce high levels of this theta frequency. (RAVE &...
Page 15
Schumann for Sleep – 60 min – 7.8 Hz For effective deep meditation and to improve the onset of sleep. Calms “hyper-chattery” minds. Ideal for those with insomnia who have a busy mind and tense body. Comes with a pre-set audio file ocean waves.
Page 16
ADHD from Study – 30 min - Alpha to SMR/Beta to Alpha (3 cycles) L 10 Hz to 13.5-14 Hz/R 10 Hz to 18 - 20 Hz This session has rapid transitions for mental stimulation to help keep the user “engaged” in the session. These are mostly used with ADHD children.
Page 17
AVE – Performance Performance sessions can improve your mental game (focus and concentration) as also seen in the Brain Booster sessions. Performance sessions may also be designed for emotional and game-playing visualizations for improved performance. Performance sessions may also be used for relaxing before or after an event or game.
Page 18
EMDR 0.3 Hz – 60 min – 0.3 Hz Uses a 3.3-second cycle (looking left for 1.65 seconds and then right for 1.65 seconds). Rose color in eyeset. EMDR – 60 min - 0.4 Hz Uses a 2.5-second cycle (looking left for 1.25 seconds and then right for 1.25 seconds). Rose color in eyeset.
Page 19
Chakra - Red to Violet - 60 min – 0 Hz Starts at red and ends up at violet. Includes the chakra tones from the middle C note to B note. Great for tuning the chakras. Includes ocean waves audio with chakra-based tones. Green - 60 min –...
cerebral blood flow. In order to balance intracranial pressure, the brain pushes CSF out. But when the stimulation stops, the intracranial blood volume reduces, and the brain pulls in CSF. About 10% whole- brain CSF is exchanged on each 30 second cycle. Eight, 12 and 40 Hz were found to produce more pumping than other frequencies.
EYESET COLORS Eyeset colors coincide with the research done by Marvin Sams and Nancy White, where they found that colors influence brain waves. The colors in many of the sessions will change as the frequency changes. The applications of the colors shown in the color wheel are generalities, based on client observations. The colors may be changed in the Session Settings.
SESSION SETTINGS SCREENS ESSION ONTROLS • Press to adjust the volume, brightness, and electrostim intensity. There are 20 different volume and light intensity settings. • Press to end the session with soft-off; press again to stop immediately. ESSION REFERENCES • AVE: Press and hold to open the Session Preferences screen for the current session.
Displays the AVE visual stim data: • Light shape (Classic, Sine, Triangle, Off) • Left color (RGB) (Advanced Mode) • Right color (RGB) Displays the electrostim data: • Voltage (V) • Current (mA) • (Advanced Mode) Resistance (kΩ) • Pulse width (ms) ESSION REFERENCES Button Actions...
Page 25
Specifies the volume of the paired audio file. Audio File Volume Allows the tone type to be overridden: • Default • Pulse • Monaural Tone Type • Binaural • Allows the pitch to be overridden: • Default Pitch • Custom value (100 to 1000 Hz) (Advanced Mode) Allows the heartbeat to be overridden: •...
Allows the electrostim type to be overridden for AVE sessions: • Default • • Electrostim Type 50% CES (Advanced Mode) • NOTE: This option is only available before the session is started. Allows the electrostim frequency to be overridden for AVE sessions: •...
Plug in the Eyeset: One end of the Spectrum cord connects to the jack on the left side of the Spectrum while the other end connects to the jack on the Premier. Note that only the 1 jack is interactive with the buttons on the Spectrum.
Page 28
o Press to save your changes, or to cancel. o Press-and-hold to reset the selected setting to its default value. • Press to go back to the previous screen. Menu Options Specifies the frequency mode: • Dual – Operates the left and right channels independently. •...
Specifies the eyeset left/right colors that will be seen during the session: • White (#FFFFFF) • Red (#FF0000) • Orange (#FF8000) • Yellow (#FFFF00) • Chartreuse (#80FF00) • Green (#00FF00) • Spring (#00FF80) Left/Right Color • Cyan (#00FFFF) • Azure (#0080FF) •...
Page 30
• Press to select a setting for editing: o Press to change the selected setting. o Press to save your changes, or to cancel. o Press and hold to reset the selected setting to its default value. • Press to go back to the previous screen. PTIONS Controls the complexity of the user interface: •...
When returning your device for repair, be sure to surround the DAVID Premier with at least one inch of tight packing on all sides in a strong carton. Neither Mind Alive Inc., nor courier companies will pay for damage incurred by poorly packaged goods.
Declaration of Conformity Manufacturer: Mind Alive Inc. 6716 75 St NW Edmonton, Alberta T6E 6T9 Canada Mind Alive Inc. declares under our sole responsibility that: Product Name: DAVID Premier Product Model(s): PREM1 Complies with the following European Directives: 2014/30/EU Electromagnetic Compatibility (EMC)
If you are a first-time Premier user: We advise that you always remain seated or reclined while using the DAVID Premier. We also suggest that new users begin sessions with low brightness in the eyeset. If at any time during a session, you begin to feel vertigo, nausea, euphoria, or a sense of mental instability, lower the intensity of the eyeset and lower the volume of the tones or discontinue the session.
DAVID Delight either at the premises of Mind Alive Inc. or the premises of its dealers or distributors, or the purchaser's premises. The purchaser, employees of the purchaser, clients or patients of the purchaser, or any other person designated by the purchaser for any purpose, hereby undertake to waive and disclaim any action in respect of the aforesaid terms as above.
APPENDIX A: TROUBLESHOOTING Performing a Hard Reset 1. Press and hold for 10 seconds until the device resets and the splash screen appears. Entering Test Mode 1. Make sure the device is turned off. 2. Press and hold until the device turns on and the splash screen appears. 3.
APPENDIX B: SPECIFICATIONS Physical & Environmental Dimensions 11.7 x 7.9 x 2.4 cm Weight 150 g Operating Temperature 0 °C – 45 °C Storage Temperature -10 °C – 55 °C Battery & Power Input USB 2.0 micro-B Battery Rechargeable 2000 mAh lithium-ion polymer Charging 7.5 W (5 V, 1.5 A) BC1.2, Apple, or TomTom compatible Runtime...
Page 37
Session Files Supported Formats DAVB, DAVX Max Files Max File Size 4 GB Max Duration (HH:MM) 12:00 Audio Files Supported Formats WAV (16-bit PCM, 44.1 kHz, mono or stereo) Max Files Max File Size 4 GB Max Duration (HH:MM) Mono: 13:30 Stereo: 6:45 AVE Characteristics Frequency...
Need help?
Do you have a question about the DAVID PREMIER and is the answer not in the manual?
Questions and answers