Advertisement

Quick Links

User Guide & Owner Manual
InterPuls IUC 24
InterPuls S.p.A.
Via F. Maritano, 11 - 42020 - Albinea (RE) – ITALY
Tel. +39 0522 347511
Fax +39 0522 348516
sales@interpuls.com
InterPuls S.p.A. –
THIS MANUAL IS PROPERTY OF
ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IUC 24 and is the answer not in the manual?

Questions and answers

Summary of Contents for InterPuls IUC 24

  • Page 1 User Guide & Owner Manual InterPuls IUC 24 InterPuls S.p.A. Via F. Maritano, 11 - 42020 - Albinea (RE) – ITALY Tel. +39 0522 347511 Fax +39 0522 348516 sales@interpuls.com InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN...
  • Page 2 TYPE OF DOCUMENT User Guide & Owner Manual DOCUMENT REF. CODE 1040195_MI_01.06.13 - IT EDITION Rev.01.06.2013 PRODUCT MODEL InterPuls IUC 24 YEAR OF MANUFACTURE 2013 InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN...
  • Page 3: Table Of Contents

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT INDEX GENERAL GUIDANCE AND SECURITY WARNINGS ..........3 BEFORE USING THE PRODUCT ................4 ASSEMBLY, DISMANTLING AND START-UP ............. 4 DISPOSAL ........................4 FIRE SAFETY ......................5 REFERENCES OF APPLIED LAWS ................5 BRANDING........................
  • Page 4 1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual IUC 24 MENU FEATURES ..................16 12.1. Menu 1.1 & Menu 1.2 – Setup Pulsation Parameters SET1 and SET2 ....18 12.1.1 Setup Pulsation Frequency (FREQ.) ............18 12.1.2 Front Ratio Setup (RATIOF) ............... 18 12.1.3 Rear Ratio Setup (RATIOR)................
  • Page 5: General Guidance And Security Warnings

    Non-compliance with the warnings presented in this manual can lead to the malfunctioning of the machinery or damage to the system. InterPuls S.p.A. denies any liability for damages caused to persons, animals Disclaimer or objects through the misuse of the machinery.
  • Page 6: Before Using The Product

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 2. BEFORE USING THE PRODUCT Rules and ATTENTION requirements for Before using the device, the operator must carefully read the authorised staff manual. The device must be used by people over the age of 18, who have been trained, are physically and mentally fit and have been given appropriate information relating to how it operates.
  • Page 7: Fire Safety

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT 5. FIRE SAFETY Preliminary remark NOTE: The device does not include a fire extinguisher. The operator must ensure that the installation location is equipped with an adequate number of suitable fire extinguishers, placed where they are visible and protected from any damage or improper use.
  • Page 8: Warning Signs

    8. WARNING SIGNS Signs displayed on the device Figure 2 ATTENTION REMOVE POWER Before opening the cover the IUC 24 must be disconnected from the electricity network. ATTENTION Damage or removal of the warning signs is absolutely forbidden. InterPuls S.p.A. –...
  • Page 9: Description Of Device

    Average absorption per coil 3,2W at 24Vcc Dimensions (LxWxH) 370 x 265 x 145 mm When switched on the first line of the screen reads “Interpuls” and the second displays the software version installed. InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF...
  • Page 10: Power Supply

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 10.1. Power supply Power supply 100265Vac 50/60Hz with filter for standard interferences Current absorption 3,5A @ 115Vac 1,7A @ 230Vac Network connection Three-pole connector with screw terminals (included) Fuses on the Two 6.3A (T)
  • Page 11: Programmable Parameters

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT 10.3. Programmable parameters Pulsation parameters IUC 24 allows the following pulsator parameters to be set to operate pulsators not equipped with programmable boards (e.g. InterPuls LE):  FREQ.: pulsation frequency ...
  • Page 12: Range Of Values

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 10.5. Range of values SET1 & SET2 Parameter Default settings Selectable values FREQ. 30260 Pulsations/minute RATIOF 60-40 10-90 ÷ 90-10 Front RATIOR 60-40 10-90 ÷ 90-10 Rear PHASE T - T/2 - T/3 - T/4 - T/5 - T/6 - T/7 - T/8...
  • Page 13: Connection And Installation

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT 11. CONNECTION AND INSTALLATION 11.1. Wall mounting of control box The control box can be wall mounted or fixed to an appropriate support using Assembly system screws. Figure 3 NOTE: Screws are not supplied...
  • Page 14: Cover Opening

    To remove the cover unscrew the 6 screws positioned on the side of the cover. Cover opening Figure 4 WARNING TURN OFF CURRENT Before opening the cover for the IUC 24 must be removed from the power supply. WARNING Do not completely remove the screws from the cover.
  • Page 15: Control Box Without Protective Cover

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT 11.3. Control box without protective cover Control box layout Figure 6 Figure 7 1 – Switching current for pulsator 5 – Cable glands for pulsator channels channels 2 – Pulsator control board 6 –...
  • Page 16: Electrical Connections

    ATTENTION REMOVE POWER Before removing the cover the power supply to the IUC 24 must be removed. Connect the power cable of the electricity network to the CN2 separable...
  • Page 17: General Connection Diaram

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT 11.5. General connection diagram General connection layout Figure 10 11.6. Adjustment of screen contrast To adjust the contrast of the screen rotate the knob located on the display Regulation procedure board:...
  • Page 18: Cover Assembly

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 11.7. Cover assembly Ensure the screws are sufficiently distanced from the support to ensure the edge Cover assembly of the cover can slot through. procedure Figure 12 Lay down the rear edge of the cover on the 4 screws positioned on the rear part of the support, taking care not to damage the components and the cables enclosed within the control box.
  • Page 19 IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT To access the control box main menu it is necessary to: Procedure for Switch on the control box accessing main menu Wait for the equipment to display the channel functionality data indicating...
  • Page 20: Menu 1.1 & Menu 1.2 - Setup Pulsation Parameters Set1 And Set2

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual Menu 1.1 & Menu 1.2 – Setup Pulsation Parameters SET1 and SET2 12.1. 12.1.1 Setup Pulsation Frequency (FREQ.) Enter Menu 1.1 SETUP SET1 Parameter adjustment procedure Scroll the parameters until the FREQ page is displayed...
  • Page 21: Rear Ratio Setup (Ratior)

    NOTE: Defined as “T” the time of a complete pulsation cycle expressed in milliseconds, the phase displacement “delay” between the wave forms of the four IUC 24 channels is equal to the value indicated on screen. InterPuls S.p.A. –...
  • Page 22: Reverse Setup (Reverse)

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 60/40 ratio, cycle duration 1000Ms The diagram represents a T/2 setting ( 500Ms delay between each channel ) Figure 16 [CHANNEL 1 / CHANNEL 2 / CHANNEL 3 / CHANNEL 4] Phase setup Enter Menu 1.1 SETUP SET1, scroll the parameters until the PHASE...
  • Page 23 IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT NOTE: If a 60/40 ratio is set in the RATIOF menu and if the REVERSE function is set to ON, an output ratio of 40/60 is obtained. Enter the Menu 1.1 SETUP SET1, scroll the parameters until the...
  • Page 24 1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual Figure 18 InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN MI - 22...
  • Page 25: Menu 1.3 - Operating Hours Counter

    1040195_MI_01.06.13-IT Menu 1.3 – Operating Hours Counter 12.2. The IUC 24 control box can count and log the operating house of the device. Preliminary remark It is possible to set a time after which a message displayed, along with an intermittent alarm signal to inform the operator that the maintenance staff must be contacted to carry out the periodic check.
  • Page 26: Next Maintenance Setup

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 12.2.2 Next maintenance setup The screen displays the number of hours currently set between the reset (see Preliminary remark 12.2.1.) and the next periodic check alert Adjustment of set value procedure Press the key.
  • Page 27: Menu 1.4 - Pulsators Current Voltage

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT Menu 1.4 – Pulsators Current Voltage 12.3. The IUC 24 control unit allows the current voltage supplied to the pulsators to be Preliminary remark viewed. Select the MENU 1.4 VOLTAGE page from the main menu...
  • Page 28: Menu 1.6 - Software Version

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual Menu 1.6 – Software Version 12.5. When the Main Menu page entitled MENU 1.6 VER SOFTWARE is selected, the Viewing procedure second line of the display will show the software version installed in the device.
  • Page 29 IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT Press to select the desired language Press to confirm. NOTE : Once the desired language has been selected, the control unit returns to the Main Menu page entitled MENU 1.8 and all the pages of the menu are now displayed in the chosen language.
  • Page 30: Map Of The Menus

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 13. MAP OF THE MENUS GENERAL TREEVIEW Figure 19 InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN MI - 28...
  • Page 31 IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT Menu 1.1 SET 1 Figure 20 Menu 1.2 SET 2 Figure 21 InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN MI - 29...
  • Page 32 1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual Menu 1.3 TIMER Figure 22 Menu 1.5 CURRENT Figure 23 Menu 1.7 DEFAULT Figure 24 InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN MI - 30...
  • Page 33 IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT Menu 1.8 LANGUAGE Figure 25 InterPuls S.p.A. – THIS MANUAL IS PROPERTY OF ANY REPRODUCTION, EVEN PARTIAL, IS STRICTLY FORBIDDEN MI - 31...
  • Page 34: Switching On For The First Time

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual Menu 1.9 START DELAY Figure 26 14. SWITCHING ON FOR THE FIRST TIME First time procedure WARNING Before switching on, ensure that all the connections have been correctly installed as indicated in the paragraph - Errore. L'origine riferimento non è...
  • Page 35: Switching On After The First Time

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT Figure 27 Wait until the control unit starts up and enters its normal operation cycle. The following data are displayed Press the button and enter the password 1 3 2. Set the pulsation parameters as explained in paragraph 12.1 - Menu 1.1 &...
  • Page 36: Troubleshooting And Alerts

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual By pressing the button, it is possible to display the information relative to a specific channel, without having to wait for the automatic scrolling. In order to switch from the settings stored for SET1 to those stored for SET2, hold down the button for at least 3 seconds.
  • Page 37: Excessive Current

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT 16.2. Excessive current Problem Encountered No command to the pulsators; no pulsation on some of the pulsator channels. Checks to be performed During operation, the normal Stand-by screen alternates with another indicating “SHORT CIRCUIT”.
  • Page 38: Memory Error

    1040195_MI_01.06.13-IT IUC 24 - User Guide & Owner Manual 16.3. Memory error Problem Encountered The control unit is not operating correctly and one of the following messages is displayed: Checks to be performed Switch off the control unit and wait for 30 seconds before switching it on again. Check whether the error message is still displayed.
  • Page 39: Low Pulsator Command Voltage

    IUC 24 - User Guide & Owner Manual 1040195_MI_01.06.13-IT 16.5. Low pulsator command voltage Problem Encountered The control unit displays the following message: This message alternates on the display with the normal message indicating that pulsator control is in operation (2sec ON - 10sec OFF) Solutions Contact Service immediately.

Table of Contents