Tronair 17A7503G7000 Operation & Service Manual

Tronair 17A7503G7000 Operation & Service Manual

Mobile air conditioner (mach-iv) 230 vac-3 phase-60 hz with heater option

Advertisement

Quick Links

Operation & Service Manual
Model: 17A7503G7000
Mobile Air Conditioner (MACH-IV)
230 VAC − 3 Phase − 60 Hz
with Heater Option
10/2009 − Rev. 05
Includes Illustrated Parts Lists
For Spare Parts, Operations & Service Manuals or Service Needs
Scan the QR code or visit Tronair.com/aftermarket
The Tronair Group of Companies:
Tronair | EBIS | Columbus Jack | Eagle | DAE | Malabar International
Tronair, Inc.
Phone: (419) 866-6301 | 800-426-6301
1 Air Cargo Pkwy East
Web:
www.tronair.com
Swanton, OH 43558
Email:
sales@tronair.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 17A7503G7000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tronair 17A7503G7000

  • Page 1 For Spare Parts, Operations & Service Manuals or Service Needs Scan the QR code or visit Tronair.com/aftermarket The Tronair Group of Companies: Tronair | EBIS | Columbus Jack | Eagle | DAE | Malabar International Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301...
  • Page 3: Table Of Contents

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz TABLE OF CONTENTS PAGE Description ................................. 1 Usage And Safety Information .......................... 1 Usage ..............................1 Safety Precautions ..........................1 Safety Considerations ..........................2 Features, Benefits And Ratings .........................
  • Page 4 Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz REVISION DATE TEXT AFFECTED 04/2002 Major Revision 06/2006 Added Appendix III 04/2007 Modified 3.1, 6.2, and Parts Lists 12/2007 Removed Electrical Schematic 10/2009 Modified 1.0 Description, 2.1 Usage, 3.2 Ratings,...
  • Page 5: Description

    230 VAC − 3 Phase − 60 Hz This product can not be modified without the written approval of Tronair, Inc. Any modifications done without written approval voids all warranties and releases Tronair, Inc., its suppliers, distributors, employees, or financial institutions from any liability from consequences that may occur.
  • Page 6: Safety Considerations

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz USAGE AND SAFETY INFORMATION (continued) SAFETY CONSIDERATIONS Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components.
  • Page 7: Ratings

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz FEATURES, BENEFITS AND RATINGS (continued) RATINGS ARI* Capacity Ratings Nominal Standard Net Cooling Capacity Total SOUND RATING SEER Tons (Btuh) (dB)
  • Page 8: 208 Volt Versus 230 Volt

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz FEATURES, BENEFITS AND RATINGS (continued) 208 VOLT versus 230 VOLT If the 208-V unit is to be connected to a 230-V...
  • Page 9: Field Power Supply (Continued)

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz FIELD POWER SUPPLY (continued) NOTES: 1. In compliance with NEC requirements for multi motor and combination load equipment (refer to NEC Articles 430 and 440), the over current protective device for the unit shall be fuse or HACR breaker.
  • Page 10: Pre Start-Up

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz PRE START-UP Prior to operating the MACH-IV, the user should become familiar with the owner's operating manual. CAUTION! • Do not jumper any safety devices when operating the unit.
  • Page 11: Check For Refrigerant Leaks

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz PRE START-UP (continued) CHECK FOR REFRIGERANT LEAKS Locate and repair refrigerant leaks and charge the unit as follows: 1. Using both high-pressure and low-pressure ports, locate leaks and recover remaining refrigerant to relieve system pressure.
  • Page 12: Operation

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz OPERATION OPERATING INSTRUCTIONS Operate the MACH-IV in accordance with the operating instructions provided on the instrument panel. Reference Figure 5. A description of each step of the STARTING and SHUTOFF sequence is given, along with a brief discussion of what is to be expected.
  • Page 13 Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz STARTING MACH-IV (continued) WARNING! The end of the garden hose can not be higher than the condensate trap located under the air conditioning unit.
  • Page 14: Shut Off Mach-Iv

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz STARTING MACH-IV (continued) 8. Heating: Check supply air duct to ensure warm air is being discharged when the heater is on.
  • Page 15: Lubrication

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz CLEANING (continued) Use a water hose or other suitable equipment to remove dirt and debris. Clean the outer surfaces with a stiff brush in the normal manner.
  • Page 16: Troubleshooting

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz TROUBLESHOOTING Refer to Cooling Service Analysis Tables and Figure 10 − Page 11 for additional information. Cooling Service Analysis Table Problem...
  • Page 17: Parts Lists & Illustrations

    Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz TROUBLESHOOTING (continued) Refer to Cooling Service Analysis Tables and Figure 10 − Page 11 for additional information. Cooling Service Analysis Table...
  • Page 18 Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz Parts List When ordering Replacement Parts/Kits, please specify Model & Serial Number of your product. ITEM PART NUMBER DESCRIPTION 1 ....H-1335 ..........Hub .................. 1 2 ....
  • Page 19 Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz Parts List When ordering Replacement Parts/Kits, please specify Model & Serial Number of your product. ITEM PART NUMBER DESCRIPTION 8 ....Z-4734-01 ......... Weldment, Frame ............1 10 ....
  • Page 20 Model: 17A7503G7000 4 Ton Mobile Air Conditioner (MACH-IV) with Heater Option 230 VAC − 3 Phase − 60 Hz Parts List When ordering Replacement Parts/Kits, please specify Model & Serial Number of your product. ITEM PART NUMBER DESCRIPTION 13 ....H-2360 ..........Air Conditioner ..............1 14 ....
  • Page 21 APPENDIX I MSDS (R-410A Refrigerant)

Table of Contents