Download Print this page

Advertisement

Quick Links

AquaStar
User's Guide
WARNING!
Read the technical instructions before installing the bath
Read the users instructions before using the bath
Do not bring sharp objects into the bath
Contact the seller if the colours appear to be changing under or on top of the coating
If a leakage appears contact the seller immediately.
All electrical work should be perfomed by a qualified electrician
Do not leave children in the bath without supervision
Do not sit with your back or head against the skimmer
For AquaStar 150/180 a mains connection of 230V and a 2x16A with a 30mA Ground Fault Current Interrupt (GFCI) for both
phases are required. A service switch, which is closely installed to the electrical connection is recommended.
ATTENTION! If the hot tub will be countersunk e.g. in a terrace it is necessary that the access is not obstructed in any way
order to be able to service it. Service hatches should be removable without a problem.
If automatic dispensers (floating, etc.) are used, careful adjustment should be made to avoid incorrect dosage. Follow the
recommendations in our instructions.
The circulation pump also generates heat and if it is running a long time (eg, continuous filtration TM) it can raise the
temperature by several degrees in one day when the tub is well insulated.
Check the quality of the water, as well as temperature and function, regularly, don't leave the spa unmonitored for long time
periods.
2020-11-06

Advertisement

loading
Need help?

Need help?

Do you have a question about the AquaStar 150 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Polar Electro AquaStar 150

  • Page 1 Do not sit with your back or head against the skimmer • For AquaStar 150/180 a mains connection of 230V and a 2x16A with a 30mA Ground Fault Current Interrupt (GFCI) for both • phases are required. A service switch, which is closely installed to the electrical connection is recommended.
  • Page 3 AquaStar – During start up 1. Make sure the valve (A) on the right of the filter is open by pulling the red handle upwards and opening the air screw (B). Close it when water starts seeping out. 2. Make sure the valve for the circulation is open. Start and carefully open the nut (E) on top of the pump to let the air out.
  • Page 4 AquaStar – Draining Draining of water 1. The spa has four service hatches, one in each corner, two of these are attached with screws and the two others have a locking mechanism. ATTENTION! If the hot tub will be countersunk e.g. in a terrace it is necessary that the access is not obstructed in any way order to be able to service it.
  • Page 5 USER MANUAL for the SG-0007B SYSTEM This product is meant to be used for electronic control of functions for spa baths. Please read all of the instructions carefully before enjoying the spa. WARNING: Operating the system without water will cause severe damage.
  • Page 6 (Fig 2) ON/OFF key (power key): Connect the power supply and press the ON/OFF key. All the control systems are now ready to run • (indicator light is on), and the circulation and Ozone disinfection system (if one exists) will start working automatically (if the water temperature is not at the pre-set temperature, the heating system will start to work in 60 seconds).
  • Page 7 NOTE: The heater will not be activated if there is insufficient water flow that may be due to low water levels in the bath and / or poorly cleaned filter cartridge. If the heater ceases to function (e.g. after a change of water), most likely the overheating protection has activated.
  • Page 8 Summary: is selected the filtration is handled automatically in cycles of “1 hour on, 3 hours off”. is selected the filtration pump (and thus the filtration) is on continuously, 24h per day without stopping in between. If the preset temperature is higher than the actual water temperature then both the circulation pump and heater are activated until the water temperature reaches the chosen setting.
  • Page 9 AQUASTAR - CLEANING AND CHANGE OF FILTER 1. The spa has four service hatches, one in each corner, two of these are attached with screws and the two others have a locking mechanism. Open the service hatches where filter and circulation To ensure good water hygiene, it is pump are installed.

This manual is also suitable for:

Aquastar 180Ht150pasHt180pas