Intended use: The sensor is designed for installation at the top of an automatic swing pedestrian door and for connection to a low energy automatic
door operator. The sensor detects people in the door swing area with an active infrared field.
Safety Instructions
Read these operating instructions thoroughly before putting the device into operation and retain for future reference.
This product is designed to be mounted at the top of an overhead pedestrian door. See images above.
Do not use this product other than for its specified application.
Only trained and qualified personnel may install and initialize the device.
Only authorized factory personnel may perform hardware/software changes or repairs to the product.
Failure to follow these safety precautions may cause damage to sensor or objects, serious personal injury, or death.
It is the responsibility of the equipment installer to carry out a risk assessment and to install the system, in compliance with applicable local,
national and regulations, safety standards, codes and laws.
Always consider the safety functions of your applications as a whole, never just in relation to one individual section of the system.
The sensor should only be operated from a low voltage system with safe electrical separation from high voltage systems. The wiring must be
protected against mechanical damage.
If the front cover 4 breaks, there is a risk it may shatter.
The sensor may only be operated in the aluminum rail provided for this purpose.
Parts of the sensor may become warm during operation.
Avoid touching any electronic and optical components.
Start-Up
Recommended start-up sequence: 1. Mount the aluminum rail, 2. Connect mounting sensor/cables, 3. Adjust the angle, 4. Initialization.
The start-up procedure below covers virtually all applications. However, you may have a need of a particular application not described here. In this
case, contact SDC technical support.
1. Mounting the aluminum rail
1.1. The rail 1 does not have any mounting
holes, make some in the rear of the
profile and mount it using the #8 x 5/8"
screws supplied so that it is horizontal
(use of a level is recommended)
Important: The aluminum profile must
lay flat against the mounting surface.
P:\INST-INSTRUCTIONS\ADA CONTROLS\INST-AUTOIR36_48
INSTALLATION INSTRUCTIONS
AUTO-IR36 & AUTO-IR48
DOOR-MOUNTED PRESENCE SENSOR
1.2. If the front cover 4 or rail needs to be
cut to size, lay it on flay, clean surface
and cut it using a fine tooth hacksaw, a
metal cutter or a rotary tool (with an
appropriate attachment). To attach the
cover after initialization (a.) remove
protective foil. (b.) Insert the top of the
cover 4 , then click the bottom of the
cover into place.
REV -
1
Aluminum Rail
2
Sensor (US Beam)
3
End Cap 2x
4
Front Cover
5
Bearing Clamp 2x
6
Screw Terminal
(Not visible in figure)
7 Mounting screws 2x
a
b
10-24
Page 1
1.3. Mount the end caps 3 after attaching
the cover. Punch through the screw hole
on the end cap. Secure the end caps
with the supplied screws being careful to
align the end cap pins with the pin guides
on the rail.