Users need to have insight in the dangers of operating this device. • Electrical devices are no toys. Therefore, store and use this device out of reach of children. 2 | IMD3...
Page 3
WARNING! supply available. If the IMD3 not work properly or the housing is damage, shut off the installation and go to a • Be aware other devices do not cause a short circuit at the contacts of the device. certified company and let the system inspected to ensure the security of the system, or send •...
Under normal circumstances where 230Vac is Isolation failure The IMD3 has been designed for installations present in the MAINS, the IMD3 does not register MAINS with correct earthing: where 230Vac is being generated by inverters. an ‘Isolation failure’ . This is due to the inverter...
PE-Pipe or connected directly with the Remote and the IMD3 Remote contacts. vehicle’s chassis. Position the IMD3 in a closed off area, which • When Connected to a an external 230Vac grid can only be carried out by qualified and make sure this grid is properly grounded and authorised personnel.
Page 8
• Select: Do not use VS (Virtual Switch) - Select: Start assistant and follow instructions • Select: Start assistant and follow instructions - Select Tab: Assistants - Select: Add Assistant - Select: safety switch - Select: Start assistant and follow instructions 14 | IMD3...
Page 9
• Select: >> • Select: Send settings - Select: Send settings • Select: All settings - Select: All settings - Window: Input - Select: Switch the unit off when: temperature sense input is opened - Select: >> 16 | IMD3...
In Victron VE.Config: Tab Inverter -> Clear the selection of the ‘ground relay’ checkbox. Diagram 5 If everything is connected correctly and the ground relay is disabled, you can test whether the isolation guard activates after switching on your inverter. 18 | IMD3...
Page 11
125 °C RTI IMP UL 746B 1.5 mm 105 °C 2.5 to 2.8 mm 105 °C 3.0 mm 105 °C RTI Str UL 746B 1.5 mm 125 °C 2.5 to 2.8 mm 125 °C 3.0 mm 125 °C 20 | IMD3...
Earth fault active Vin-0.45 aggressive detergents Iout2 trip current (PPTC Vin max = 60V Use in parallel The IMD3 can’t be use resettable fuse) in parallel or with other Iout2 hold current (PPTC Vin max = 60V insulation monitors resettable fuse)
Page 14
Emission EN 61000-3-3 (2013) +A1 (2019) + A2 (2021) + AC (2022) (not yet harmonized) Emission / Immunity EN 61326-2-4 (2013) Electrical Safety IEC 61557-1 IEC 61557-8 IEC 61010-1 IEC 61010-2-030 The EMC reports can be downloaded on our website. 26 | IMD3...