abi TPR 3000 Series User Manual

Thyristor power controller

Advertisement

USER MANUAL
THYRISTOR POWER CONTROLLER
--------------------------------------------------------Cautions for Your Safety-----------------------------------------------------
Please Keep these instructions and review before using this controller.
This instruction manual uses WARNING and CAUTION as signal words for safety.
WARNING
WARNING indicates a potentially hazardous situation which,
!
if not avoided, will result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, will
result in minor moderate injury and at other times will result in death or serious
injury. I may also be used to alert against unsafe practice.
WARNING indicates a potentially hazardous situation which, if not avoided,
!
will result in death or result in death or serious injury.
1. In case of using this unit with machineries (Warehouse, Medical equipments, vehicle,
train, airplane, nuclear power or safety devices etc.), it requires installing fail safe device.
 It may result in serious damage or fire injury.
2. Use a rated voltage to prevent damage or trouble.
 It may result in fire
3. Check the number of terminals when connect each line and signal input.
 It may cause fire or trouble.
4. Do not turn on the power until the wiring completed.
 It may cause electric shock.
5. Do not repair, wiring or checkup when electric power on.
 It may cause electric shock.
6. Install the controller where there is no dust, corrosive or explosive gas, direct ray of the
sun, mechanical vibration or shock present.
 It may cause fire or explosive.
7. This controller must be mounted on panel.
 It may cause electric shock.
8. Do not repair beyond of authorized technician.
 It may cause trouble.
TPR 3000 Series
-1-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPR 3000 Series and is the answer not in the manual?

Questions and answers

Sachin Balaji Desale
August 6, 2025

Cooling Fan is not Working in that what should we do

User image 6892dd5a232d8
UPENDER KUMAR
June 8, 2025

TPR 3000 CONTROLER ALRAM IN OTP WHO TO CHECK

Summary of Contents for abi TPR 3000 Series

  • Page 1 TPR 3000 Series USER MANUAL THYRISTOR POWER CONTROLLER --------------------------------------------------------Cautions for Your Safety----------------------------------------------------- ◙ Please Keep these instructions and review before using this controller. ◙ This instruction manual uses WARNING and CAUTION as signal words for safety. WARNING WARNING indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 2 ◙ CAUTION: indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury and at other times will result in death or serious injury. I may also be used to alert against unsafe practice. Installation Guidelines: 1.
  • Page 3: Installation And Wiring

    1. General TPR 3000 Series is up-graded from series with advanced digital technology. It may reliability and stability temperature control due to advanced digital technology. 2. Feature ntrol Input: Analog (4-20mA/0-20mA/1-5V/0-5V)  Co Indicating of analog signal.   Automatic Output-limit cognition of external volume or internal limit setting.
  • Page 4 3.2 Wiring 1. Power Prior to applying power, ensure the supply voltage is connected to the correct terminals as ordered specification or marked on the electrical connection diagram. Connect the power supply voltage to input line terminals. Tighten the power connections correctly. Poor tightening can lead to incorrect operation of the unit and can have serious consequences on the installation.
  • Page 5: General Arrangement

    Note 1) Keep isolated between control signal line and power line. Note 2) Ensure the power supply output voltage(+,-) for the remote controller does not shortage. Table 2. Control signal terminal Position Name Assignment Note L(Line) 230V AC ± 10%, Auxiliary Power Supply 50/60Hz.
  • Page 6: Operation

    Input Terminals Display & Key Pad M E N U E N T Control Terminals Output Terminals Output Terminals Fig: Front View of the thyristor 5.Operation 5.2.Monitoring Parameters Percentage of Load Press for 2sec. Amps R-Phase Current Amps T-Phase Current Heat sink Temperature...
  • Page 7 5.2.Operating Parameters...
  • Page 8: Technical Specifications

    - 355(w) x 570(h) x 325(d)mm. Note: For transformer primary load Tesla of transformer should be less 1.1T ABI INSTRUMENTS (P) LTD., TS84, Industial Estate, Ekkaduthangal , Chennai – 600 032, India Ph: -91-44-45540025 / 45540026, Fax: 91-44-42010488, Mob: 9840832293/95/96 Email: sales@abiindia.in ,...

Table of Contents

Save PDF