London Electronics FUSION Installation & Operating Manual

Large 6 digit counter/rate display

Advertisement

Quick Links

F04.07
Version 1.0
Publication date 12-07-2024
Model FUSION-C
Installation & Operating Manual
Easy setup
Up to 4 inputs NPN, PNP, 24V & Contact Closure
Fully Scalable
Total, Rate & Quadrature Modes
Optional Output 4-20mA / 0-10V isolated
Optional Alarm output = 2 or 4 relays Optional
Comms Output = RS232 or RS485 95-230V AC or
11-30V DC power
Caution: There is a risk of electrical shock if this instrument is
not properly installed
Caution: Risk of danger: Read the whole manual before you
install this meter
www.london-electronics.com
Revision 6
!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FUSION and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for London Electronics FUSION

  • Page 1 Model FUSION-C Installation & Operating Manual Revision 6 Easy setup Up to 4 inputs NPN, PNP, 24V & Contact Closure Fully Scalable Total, Rate & Quadrature Modes Optional Output 4-20mA / 0-10V isolated Optional Alarm output = 2 or 4 relays Optional...
  • Page 2: Table Of Contents

    FUSION-C Users Manual Table of Contents Warranty ..............................1 Warnings ..............................2 Introduction............................3 General Description ..........................4 Suspension Mounting Dimensions......................5 Wall Mounting Dimensions........................6 Panel Mounting Dimensions ........................7 Connections............................8 Connections............................9 Installation Hints For Best Performance ...................10 48V AC Power Wiring Option ......................12 Display Brightness ..........................13 Input Signal Configuration .........................14...
  • Page 3 FUSION-C Users Manual Production Rate Mode ........................26 Production Rate Mode - Continued ....................27 Production Rate Mode - Application Notes..................28 Quadrature Mode..........................29 Quadrature Mode - Application Notes ....................30 Logic Input Functions .........................31 Logic Input Connections & Front Buttons ..................32 Last Digit Rounding Up By 1, 2, 5, 10, 20 or 50 ................33 Scale Factor Adjustment ........................34...
  • Page 4: Warranty

    FUSION-C Users Manual Warranty We warrant this product against defects in materials or workmanship for a period of three (3) years from the date of purchase. In the event of a defect during the warranty period, the unit should be returned, freight (and all duties and taxes) prepaid by the Buyer to the authorised distributor from where the unit was purchased.
  • Page 5: Warnings

    FUSION-C Users Manual Warnings Please carefully read this manual and all warnings. Install the meter ONLY when you are sure that you’ve covered all aspects. Where the product is intended for “UL” installations, removal or addition of option boards is not permitted.
  • Page 6: Introduction

    FUSION-C Users Manual Introduction Please contact us if you need help, if you have a complaint, or if you have suggestions to help us improve our products or services. If you contact us about a product you already have, please tell us the full model number and serial number, so that we can give you accurate and fast help.
  • Page 7: General Description

    FUSION-C Users Manual General Description This series of meters accepts industrial sensors to allow various physical measurements to be made, such a weight, temperature, pressure, humidity etc. Different models are available for different sensor types. The main function of this series is to give a numeric readout of the variable being monitored.
  • Page 8: Suspension Mounting Dimensions

    FUSION-C Users Manual Suspension Mounting Dimensions 15mmO 15mmO 6.35mmO 6.35mmO Plan View 25mm X mm Y mm Short-drop mounting holes Long-drop mounting holes W mm 77 mm 8.8.8.8.8.8. H mm H mm 25mm Cable Glands. Number of glands depends on installed options.
  • Page 9: Wall Mounting Dimensions

    FUSION-C Users Manual Wall Mounting Dimensions 98 mm W mm 22mm 60 mm 8.8.8.8.8.8. H mm 25mm Cable Glands. Number of glands depends on installed options. 80 mm 60 mm The 4 bracket holes are 5.2mm diameter 60 mm X mm 72.5 mm...
  • Page 10: Panel Mounting Dimensions

    FUSION-C Users Manual Panel Mounting Dimensions 67mm 8.8.8.8.8.8. 25mm H mm A mm Neoprene Bezel W mm gasket Neoprene Cable glands gasket B mm Detail showing bracket hardware fitting sequence Bezel Panel cutout dimensions Neoprene gasket Panel A+3mm(h) x B+3mm(w)
  • Page 11: Connections

    FUSION-C Users Manual Warning: Connections Disconnect all power before removing the rear of the display There is a wide range of possible locations for the input board, output board and power supply board/s. Their locations depend on the height of digits, number of digits, brightness of digits and any installed options.
  • Page 12: Connections

    FUSION-C Users Manual Connections Warning: Disconnect all power before removing the rear of the display Output option board (if fitted) Connectors and options Analog Connectors may be Serial Data 0, 2 or 4 Alarm Relay output present even if output...
  • Page 13: Installation Hints For Best Performance

    FUSION-C Users Manual Installation Hints For Best Performance This section offers several suggestions which will help you get the best performance from your measurement system. Some sensors generate comparatively small signals which can easily be corrupted by the potentially high level of electrical noise which can be created by electrical machinery such as motors, welding systems, discharge lighting, AC power inverters and solenoids.
  • Page 14 FUSION-C Users Manual Page 11 www.london-electronics.com...
  • Page 15: 48V Ac Power Wiring Option

    FUSION-C Users Manual 48V AC Power Wiring Option Page 12 www.london-electronics.com...
  • Page 16: Display Brightness

    FUSION-C Users Manual Display Brightness You can adjust the display brightness at any time, provided the display is locked. Set1 Set2 Output Alarms Digit Lockout Switch must be ON Max/Min Reset Circuit board Press 3 seconds Set1 Set2 Output Alarms...
  • Page 17: Input Signal Configuration

    FUSION-C Users Manual Input Signal Configuration Each of the display’s 4 inputs can be configured to accept different types of input signals, using the procedure below..Set2 Output Set1 Alarms Lockout Switch must be OFF Digit Max/Min Reset Circuit boardON Press 3 seconds Display shows input channel choices...
  • Page 18: Input Signal Configuration - Continued

    FUSION-C Users Manual Input Signal Configuration - Continued Display shows edge count choices in Set2 Output Set1 Alarms the following modes:- Digit Max/Min Reset 1in.u.d, 2in.u.d, 2in.u.u.,4 uudd, 4 uuuu, 4 dddd, quad. Press to select an Edge choice then press OK to accept.
  • Page 19: Input Signal Configuration Guide

    FUSION-C Users Manual Input Signal Configuration Guide This table tells you which settings to choose for each input signal type. The sensor should be connected to the display according to the connection diagram page. Sensor family Input Signal Type Input signal loading Input de-bounce puls.dc...
  • Page 20: Display Modes

    FUSION-C Users Manual Display Modes You can choose from eleven basic display modes, some of which have extra sub- modes. Set1 Set2 Output Alarms Lockout Switch must be OFF Digit Max/Min Reset Circuit board Press 3 seconds Display shows... Set1...
  • Page 21: Factory Defaults

    FUSION-C Users Manual Factory Defaults You can return the display to its factory default conditions whenever you wish. If you do so, you will permanently loose all your settings and will need to start from the beginning again. The calibration Audit Counter will NOT be reset, there is no way provided to reset this value, as it is intended as a secure record to indicate whether changes have been made to the display since it was last calibrated..
  • Page 22: Simple Rate Mode

    FUSION-C Users Manual Simple Rate Mode Rate mode is ideal for showing instantaneous speed, RPM, frequency, production rate, flow rate etc. For production rate showing the true number of items produced in the last hour, consider using our ‘Production Rate Mode’ method, which is ideal for production which is erratic or has periods of widely differing production rate.
  • Page 23: Simple Rate Mode - Continued

    FUSION-C Users Manual Simple Rate Mode - Continued will appear, prompting you to enter a Set1 Set2 Output Alarms Digit delay time in seconds, so that if no pulses are Max/Min Reset received within this time, the display will revert to...
  • Page 24: Application Notes - Rate Mode

    FUSION-C Users Manual Application Notes - Rate Mode RPM Measurements We can accept any number 2866 of pulses per rotation, from 1 upwards. Input 1 Bolt(s) to create pulse in sensor = (60/pulses per rotation) Rotating part Proximity sensor Frequency Measurements Ideal for the precision measurement of generator or inverter grid frequency.
  • Page 25: Period Mode

    FUSION-C Users Manual Period Mode Rate mode is ideal for showing instantaneous speed, RPM, frequency, production rate, flow rate etc. For production rate showing the true number of items produced in the last hour, consider using our ‘Binned Rate’ method, which is ideal for production which is erratic or has periods of widely differing production rate.
  • Page 26: Application Notes - Period Mode

    FUSION-C Users Manual Application Notes - Period Mode Bake timer eg. With 0.255 seconds Oven Heater between each pulse, the bake time is 36 minutes Bread 36.0 Conveyor Input 1 minutes Bolt(s) to create pulse = 255 in sensor = 36.0...
  • Page 27: Totalising Modes

    FUSION-C Users Manual Totalising Modes There are several useful totalising modes available, which use 1 or more of the display’s logic input ports. The total will be stored on loss of power, and will be restored when power is returned to the display.
  • Page 28: Totalising Modes - Application Notes

    FUSION-C Users Manual Totalising Modes - Application Notes The 8 totalising modes are ideal for counting pulses, where 1 pulse = 1 item, or the total can be scaled, for example to show total flow of liquid, where 1 pulse may represent a certain volume of liquid according to the relationship between “...
  • Page 29: Production Rate Mode

    FUSION-C Users Manual Production Rate Mode In this mode four inputs are available, two can add to give a combined total, and two can subtract to give combined rejects. This mode of rate measurement is ideal for showing real production rates over longer periods, for example showing items per hour, for the previous hour, updated every 15 seconds, 5 minutes, or whatever best suits your process.
  • Page 30: Production Rate Mode - Continued

    FUSION-C Users Manual Production Rate Mode - Continued will appear, prompting you to enter a Set1 Set2 Output Alarms Digit value for the number of bins to use. Default is 0, Max/Min Reset maximum is 200. See opposite for a guide how to choose the best value.
  • Page 31: Production Rate Mode - Application Notes

    FUSION-C Users Manual Production Rate Mode - Application Notes 1. Choose an averaging time, in seconds, you want to use for computing your production rate. For example if you want to average over 45 minutes, your averaging time will be 2700 seconds.
  • Page 32: Quadrature Mode

    FUSION-C Users Manual Quadrature Mode The quadrature mode allows you to scale a count and increase or decrease the value according to the sequencing of two pulses which are 90 degrees out of phase. This mode is ideal for measuring distance in pay-out/feed-in cable systems, or direction in rotary systems.
  • Page 33: Quadrature Mode - Application Notes

    FUSION-C Users Manual Quadrature Mode - Application Notes In a quadrature sensor, the two incoming pulses overlap. Pulses to input 1 will arrive before or after pulses to input 2, depending on the direction of movement. This is achieved by staggering the trigger zones for sensor A and B. They must overlap, so that one will lead the other in one direction, and vice-versa.
  • Page 34: Logic Input Functions

    FUSION-C Users Manual Logic Input Functions The three contact closure inputs on the rear of the meter have default functions which are:- Contact closure 1 = Tare Contact closure 2 = Peak/Valley display Contact closure 3 = Reset You can re-assign these to include :HOLD, Nett/Gross value display, Memory...
  • Page 35: Logic Input Connections & Front Buttons

    FUSION-C Users Manual Logic Input Connections & Front Buttons The previous page explained how to select the functions of the 3 logic inputs. You can connect remote contact closures or open NPN collectors to activate these logic inputs. The logic input provides a 5V DC signal. When you connect this to common, a current of 1mA will flow.
  • Page 36: Last Digit Rounding Up By 1, 2, 5, 10, 20 Or 50

    FUSION-C Users Manual Last Digit Rounding Up By 1, 2, 5, 10, 20 or 50 You can adjust the way the display rounds up, which is useful if you want to display a very large number, but do not want jitter on the last digit.
  • Page 37: Scale Factor Adjustment

    FUSION-C Users Manual Scale Factor Adjustment After you have calibrated your meter, you can use the SCALE feature to make fine adjustments to calibration, without affecting the calibration itself. Example 1. Changing weight units of measure from kg to pounds You could also use the SCALE to convert your readout from kg to pounds, without affecting the calibration.
  • Page 38: Offset Adjustment

    FUSION-C Users Manual Offset Adjustment After you have calibrated your meter, you can use the feature to make fine additions or subtractions to the reading, without affecting the calibration itself. Set1 Set2 Output Alarms Digit Max/Min Reset Lockout Switch must be OFF...
  • Page 39: Menu Timeout Adjustment

    FUSION-C Users Manual Menu Timeout Adjustment The display has a default timeout of 60 seconds, to allow you sufficient time to refer to the manual between key operations. You can make this period shorter, if you wish, once you become more familiar with the setup method.
  • Page 40: Reverse Display Function (Mirror Image)

    FUSION-C Users Manual Reverse Display Function (Mirror Image) If you need to be able to see a reflection of the display in a mirror or other reflective surface, for example in a simple heads-up system, or for drivers reversing into a bay, using mirrors only, you can set the display to show as a mirror image.
  • Page 41: Bootup Routine & Tare Save Choices

    FUSION-C Users Manual Bootup Routine & Tare Save Choices When you switch on your meter, it can be set to power up with 3 possible summary message combinations. The choices are:- Segment test, followed by a full summary of software revision, calibration audit number, model number, installed options.
  • Page 42: Language Selection For User Interface

    FUSION-C Users Manual Language Selection for User Interface You can select English or French menu prompts. Set1 Set2 Output Alarms Digit Max/Min Reset Lockout Switch must be OFF Press together, briefly Circuit board Display shows Set2 Output Set1 Alarms ui.Eng...
  • Page 43: Multi-Program Memory Option 'Mem

    FUSION-C Users Manual Multi-Program Memory Option ‘MEM’ The three contact closure inputs on the rear of the meter may be used to call up between 1 to 7 additional meter setup memories (pages), if the MEM option has been installed.
  • Page 44: Error Codes & Fault Findings

    FUSION-C Users Manual Error Codes & Fault Findings 1. Under Range. The meter is being asked to display a value which is more negative than its limit of -1999 2. Over Range. The meter is being asked to display a value which...
  • Page 45: How To Install Option Boards

    FUSION-C Users Manual How To Install Option Boards Warning: Disconnect Where the product is intended for “UL” installations power before you expose removal or addition of option boards is not permitted. the internals of the display If you want to open your display to install or modify option boards, follow these steps...
  • Page 46: Waste Electrical Electronic Equipment (Weee)

    FUSION-C Users Manual Waste Electrical Electronic Equipment (WEEE) In Europe, this equipment must be disposed of in accordance with European parliamentary Directive 2002/96/EC This directive encourages recycling and the reduction of waste materials in the environment. This means it must be sent to an approved recycling plant if you want to dispose of it.
  • Page 47: Equipment Specifications

    FUSION-C Users Manual Equipment Specifications Page 44 www.london-electronics.com...
  • Page 48: Record Of Revisions

    FUSION-C Users Manual Record of Revisions 6 September 2010 Version F00.18 Software released. Manual format revised to improve clarity and segregate easy from advanced menu functions. Optional outputs now described in their own dedicated manuals. Cabling guidance added. 1 February 2011 Version F00.21 software released.
  • Page 49 FUSION-C Users Manual Page 46 www.london-electronics.com...
  • Page 50: Declaration Of Uk & Ce Conformity

    Signal cabling shall be routed separately to power carrying cabling (includes relay output wiring) All signal cabling shall be screened. The screen shall only be terminated to the power earth terminal at the meter end of the cable. Declared as true and correct, for and on behalf of London Electronics Ltd. J.R.Lees Director Page 47 www.london-electronics.com...

This manual is also suitable for:

Fusion-cSs-fusion-cExnr-fusion-c

Table of Contents