Item no. 15970-5-9970 · ENU · Change 256827 · Approved 2022-05-10 · Page 1 / 11
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
3
4
4
5
5
5
5
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
7
maintained and otherwise used by suitably qualified, trained and
8
authorized technical staff.
9
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
9
following installation in the final product.
10
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S2D170-BA04-08 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst S2D170-BA04-08

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions S2D170-BA04-08 WARNING 1.7 Emissions Live terminals and connections even with device WARNING switched off Depending on the installation and operating conditions, Electric shock the sound pressure level may exceed 70 dB(A). → Wait five minutes after disconnecting the voltage at all poles Risk of noise-induced hearing loss before opening the device.
  • Page 3: Intended Use

    Operating instructions S2D170-BA04-08 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions S2D170-BA04-08 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Direction of air flow "A" Tightening torque 0.6±0.1 Nm Item no. 15970-5-9970 · ENU · Change 256827 · Approved 2022-05-10 · Page 4 / 11...
  • Page 5: Nominal Data

    Operating instructions S2D170-BA04-08 3.2 Nominal data Approval ; Use the device in accordance with its degree of protection. Motor M2D068-BF Information on surface quality Phase The surfaces of the products conform to the generally applicable industrial Nominal voltage / VAC standard.
  • Page 6: Connection And Startup

    Operating instructions S2D170-BA04-08 4. CONNECTION AND STARTUP NOTE Water ingress into wires or cables Water ingress at the customer end of the cable can damage the 4.1 Mechanical connection device. CAUTION → Make sure the end of the cable is connected in a dry Cutting and crushing hazard when removing fan from environment.
  • Page 7: Connection In Terminal Box

    Operating instructions S2D170-BA04-08 4.3 Connection in terminal box Fans installed upright When routing the cable, make sure that the cable glands are located at 4.3.1 Preparing cables for connection the bottom. The cables must always be routed downward. Only strip the cable as far as necessary, ensuring that the cable gland is sealed and there is no strain on the connections.
  • Page 8: Connection Diagram

    Operating instructions S2D170-BA04-08 4.4 Connection diagram Change of rotation direction by reversing two phases Three-phase motor Δ Delta connection Star connection = U1 = black = V1 = blue = W1 = brown green white yellow green/yellow Item no. 15970-5-9970 · ENU · Change 256827 · Approved 2022-05-10 · Page 8 / 11...
  • Page 9: Checking Connections

    ; Disconnect the device from the power supply at the supply line's Deficient cooling Improve cooling main switch. In the event of further malfunctions, contact ebm-papst. ; When disconnecting, be sure to disconnect the ground connection last. 5.1 Cleaning To ensure a long service life, check the fans regularly for proper operation and soiling.
  • Page 10: Safety Inspection

    6 months Only ferrite magnets and not rare earth magnets are used in external damage rotor motors from ebm-papst Mulfingen GmbH & Co. KG. Item no. 15970-5-9970 · ENU · Change 256827 · Approved 2022-05-10 · Page 10 / 11...
  • Page 11 Electrolytic capacitors ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 15970-5-9970 · ENU · Change 256827 · Approved 2022-05-10 · Page 11 / 11...

Table of Contents