Malema MPT-750-P User Manual

Mpt pressure sensor

Advertisement

Quick Links

MPT PRESSURE SENSOR
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPT-750-P and is the answer not in the manual?

Questions and answers

Summary of Contents for Malema MPT-750-P

  • Page 1 MPT PRESSURE SENSOR User Manual...
  • Page 3 2. EN61000-4-3: Radiated Immunity (and Radiated Emissions) 3. EN61000-4-4: Electrical Fast Transients 4. EN61000-4-5: Surge - Power Line 5. EN61000-4-6: Conducted Immunity Support Email Address Please contact the Malema Customer Support Team at the email addresses below, General Support: Malema.GeneralSupport@psgdover.com Customer Support: Malema.CustomerSupport@psgdover.com Order Support: Malema.OrderSupport@psgdover.com...
  • Page 4: Table Of Contents

    Index 1.00 Introduction ..........................5 1.01 Safety Precautions ...............................5 1.02 Overview ................................5 1.03 Chemicals ................................6 1.04 Storage ................................6 1.05 Maintenance ................................6 2.00 Installation ............................ 7 3.00 Standard Specifications ......................7 3.01 Performance Specifications ..........................7 3.02 Electrical Specifications ............................7 3.03 Electrical Connections ............................8 4.00 Dimensional Drawing ........................
  • Page 5: Introduction

    Modifications: Do not attempt to modify or repair the device yourself. Contact Malema Sensors for repairs. Note: Please ensure you have read the User Manual before installing the Pressure Sensor. Contact Malema Sensors if you require further assistance. Incorrect installation might result in fatal or serious injury due to malfunction or incorrect operation of the product.
  • Page 6: Chemicals

    MPT PRESSURE SENSOR 1.00 Introduction CAUTION Malema Sensor is not responsible for damage or physical injury caused by the following, • Repairs or alterations by other companies • Use of non authorized parts for maintenance causing damage • Non-compliance with the precautions outlined in this manual or improper use and service conditions •...
  • Page 7: Installation

    24 V DC ±10% Power Consumption Max 30 mA @ 24 V DC Digital Communication RS-485 Malema Addressable Sensor Network (ASN) Connector 12-Pin-HR-30 Series Hirose Connector (MPT-751-P and MPT-751-T) Cable 1 meter, 3 meter or custom length available for MPT-750-P and MPT-750-T...
  • Page 8: Electrical Connections

    MPT PRESSURE SENSOR 3.00 Standard Specifications 3.03 Electrical Connections MPT - 750 Cable Version Option G Option F Color Description Color Description 24 V DC 24 V DC Black Ground Black Ground Violet -Analog (4-20 mA) PRESS, Active Violet -Analog (4-20 mA) PRESS, Passive Blue +Analog (4-20 mA) PRESS, Active Blue...
  • Page 9 MPT PRESSURE SENSOR 3.00 Standard Specifications 3.03 Electrical Connections MPT - 751 Hirose Option A Option B Pins Description Pins Description 24 V DC 24 V DC Ground Ground -Analog (4-20 mA) PRESS, Passive -Analog (4-20 mA) PRESS, Active +Analog (4-20 mA) PRESS, Passive +Analog (4-20 mA) PRESS, Active -Analog (4-20 mA) Temp, Passive RS-485 A (+)
  • Page 10: Dimensional Drawing

    MPT PRESSURE SENSOR 4.00 Dimensional Drawing Figure 1: Figure 2: MPT Pressure Sensor Flow Through Configuration MPT Pressure Sensor Single Port Configuration MPT Size Flow through Design (Female Flare) - 1/4 101.7mm Flow through Design (Female Flare) - 3/8 106.9mm Flow through Design (Female Flare) - 1/2 127mm Flow through Design (Female Flare) - 3/4...
  • Page 11: Order Information

    8 wire cable (Power, 1 analog 0-10 V DC o/p, 2 digital o/ps, RS-485 connection) Pressure Sensor MPT-750-P only 6 wire cable (Power, 1 active analog 4-20 mA o/p and RS-485 connection) 6 wire cable (Power, 1 analog 0-10 V DC o/p and...
  • Page 12 MPT PRESSURE SENSOR 5.00 Order Information Part Number for Scheme for Sensor with Connector version Model -*** Description MPT-751-P Pressure Sensing Only MPT-751-T Pressure and Temperature Sensing Range 0-100 psig Single Port Configuration Flow Through 1/4” 3/8” Size 1/2” 3/4” (Not available in single port design) 1”...
  • Page 13: Troubleshooting

    Malema Sensors shall be relieved of any further obligation to Buyer under this section with respect to such equipment. No equipment furnished by Malema Sensors shall be deemed to be defective by reason of normal wear and tear, failure to resist erosive or corrosive action of any fluid or gas (unless otherwise specified in Quotations), Buyer’s failure to properly store, install, operate, or maintain the equipment in accordance with good industry practices or specific recommendations of Malema Sensors or in accordance with operating manuals and/or product data sheets limits, or Buyer’s failure to...
  • Page 14 MPT PRESSURE SENSOR Support Email Address Please contact the Malema Customer Support Team at the email addresses below, General Support: Malema.GeneralSupport@psgdover.com Customer Support: Malema.CustomerSupport@psgdover.com Order Support: Malema.OrderSupport@psgdover.com Quote Support: Malema.QuoteSupport@psgdover.com Technical Support: Malema.TechnicalSupport@psgdover.com India Florida California 1st, 3rd and 4th Floor, # 1433,...

This manual is also suitable for:

Mpt-750-tMpt-751-pMpt-751-t

Table of Contents