Orolia KANNAD 406 SURVIVAL Installation And Operation Manual

Orolia KANNAD 406 SURVIVAL Installation And Operation Manual

Advertisement

Quick Links

Emergency Locator
Transmitters
Orolia S.A.S.
P/N : S1823502-05
P/N : S1820511-02
P/N : S1820511-05
P/N : S1820511-03
P/N : S1820511-04
Revision 06
FEB 23/2006
First issue:
INSTALLATION MANUAL
OPERATION MANUAL
KANNAD 406 SURVIVAL
ELT, KANNAD 406 SURVIVAL
MOUNTING BRACKET, AS
MOUNTING BRACKET, AS-PLUS
CARRY-OFF BAG, AS
CARRY-OFF BAG, Short
DOC06056G
TP PAGE : 1
Date of rev. JUN 22/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KANNAD 406 SURVIVAL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Orolia KANNAD 406 SURVIVAL

  • Page 1 Emergency Locator Transmitters Orolia S.A.S. INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL P/N : S1823502-05 ELT, KANNAD 406 SURVIVAL P/N : S1820511-02 MOUNTING BRACKET, AS P/N : S1820511-05 MOUNTING BRACKET, AS-PLUS P/N : S1820511-03 CARRY-OFF BAG, AS P/N : S1820511-04...
  • Page 2 Please register a support ticket via the Orolia website: https://www.orolia.com/support/ THIS DOCUMENT IS COPYRIGHT © 2022 OROLIA S.A.S. ALL RIGHTS ARE STRICTLY RESERVED. THIS DOCUMENT AND ANY ATTACHED MATERIALS CONTAINS...
  • Page 3: Record Of Revisions

    KANNAD 406 SURVIVAL RECORD OF REVISIONS REV. Nb REVISION DATE INSERTION DATE FEB 23/2006 NOV 08/2006 FEB 01/2008 JUN 25/2008 JUL 08/2013 AUG 12/2020 JUN 22/2022 ROR PAGE: 1 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 4 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL RECORD OF REVISIONS PAGE INTENTIONALLY LEFT BLANK ROR PAGE: 2 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 5 JUN 22/2022 INTRO JUN 22/2022 System Overview JUN 22/2022 JUN 22/2022 JUN 22/2022 JUN 22/2022 JUN 22/2022 JUN 22/2022 System Functional Description and Operation JUN 22/2022 LEP PAGE: 1 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 6: List Of Effective Pages

    JUN 22/2022 JUN 22/2022 JUN 22/2022 JUN 22/2022 Check JUN 22/2022 JUN 22/2022 Troubleshooting JUN 22/2022 JUN 22/2022 Schematics and Diagrams JUN 22/2022 JUN 22/2022 JUN 22/2022 LEP PAGE: 2 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 7 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL LIST OF EFFECTIVE PAGES SUBJECT PAGE DATE JUN 22/2022 Servicing JUN 22/2022 JUN 22/2022 Disposal JUN 22/2022 JUN 22/2022 LEP PAGE: 3 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 8 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL LIST OF EFFECTIVE PAGES PAGE INTENTIONALLY LEFT BLANK LEP PAGE: 4 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 9: Table Of Contents

    Deployment from mounting bracket..............209 CHECK....................301 Self-test ....................301 Periodicity ......................301 Self-test procedure .................... 301 TROUBLESHOOTING................. 401 General ..................... 401 Faults on Self-test ................401 TOC PAGE: 1 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 10 Maintenance Schedule ..............601 Periodic inspection .................... 601 Battery replacement ..................601 Battery replacement requirements............. 602 REMOVAL ..................701 End of life statement ................701 Disposal .................... 701 TOC PAGE: 2 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 11: Introduction

    KANNAD 406 SURVIVAL INTRODUCTION The instructions in this manual provide the information necessary for the installation and the operation of the KANNAD 406 SURVIVAL ELT. Servicing instructions are normally performed by shop personnel. For servicing and maintenance instructions, refer to relevant CMM.
  • Page 12 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL PAGE INTENTIONALLY LEFT BLANK PAGE INTRO 2 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 13: System Overview

    • EPIRB (Emergency Position Indicating Radio Beacon) for maritime applications. • ELT (Emergency Locator Transmitter) for aeronautical applications. • PLB (Personal Locator Beacon) for land expeditions. Figure 1: COSPAS-SARSAT System PAGE: 1 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 14: World Coverage With The Cospas-Sarsat System

    • resistance to flame; • impact and crush tests; • resistance to 100 G shocks; • watertightness; • antideflagration; • extreme temperatures (-20°C to 55°C for more than 48 hours). PAGE: 2 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 15: Kannad 406 Survival Presentation

    "Programming Dongle" for pin-programming function. a tether ended by a hook. Figure 2: KANNAD 406 SURVIVAL Presentation with Mounting Bracket AS PAGE: 3 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 16 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL Figure 3: KANNAD 406 SURVIVAL Presentation with Mounting Bracket AS- PLUS NOTE: Mounting Bracket AS-PLUS cannot store a programming dongle. The Hook and Loop Fastener Strap used to retain the ELT is made of BMS8-285 Type IV Class2 material (BMS - BOEING MATERIAL SPECIFICATION), In addition it is fitted with snaps to secure the fixing method.
  • Page 17: Design Features

    The housing is designed to be easily taken in one hand. A tether is supplied to tie the ELT to a liferaft. KANNAD 406 SURVIVAL is fitted with a floating collar to enable the ELT to float upright if used in water.
  • Page 18 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL PAGE INTENTIONALLY LEFT BLANK PAGE: 6 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 19: System Functional Description And Operation

    SYSTEM FUNCTIONAL DESCRIPTION AND OPERATION 1. Transmitter KANNAD 406 SURVIVAL is designed to transmit on three frequencies (121.5, 243 and 406 MHz).The two basic aeronautical emergency frequencies (121.5 and 243 MHz) are mainly used for homing in the final stages of the rescue operations.
  • Page 20: Working Mode Information

    NOTE: The expiry date takes into account FAR 91-207 (i.e. batteries to be replaced when 50 percent of their useful life has expired). PAGE: 102 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 21: Technical Specifications

    RTCA DO-160D Ch. 4 to25 [ED62]XBA[ED62][RCC1]AWXXXXZXXX ZWL[(A1)(A2)(A3)XX]XXA Note: Ch. 6, 9, 10 according to DO-160C. QUALIFICATIONS ETSO-2C91a & ETSO-2C126 (EUROCAE ED62) TSO-C91a & TSO-C126 (RTCA DO183 & DO204 PAGE: 103 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 22: Manual Activation

    - 121.5 / 243 MHz transmission starts immediately after the self-test. - 406 MHz transmission starts after 50 seconds. - During transmission, buzzer operates and visual indicator flashes periodically. PAGE: 104 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 23: Water Switch Activation

    Put the ELT in the water to float safely. Check that buzzer operates and visual indicator flashes periodically. The ELT should float with antenna in vertical position PAGE: 105 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 24: Reset

    IMPORTANT: As 406 MHz transmission is effective 50 seconds after the ELT activation, if it is reset within this delay, no further radio contact will be necessary. • Switch to " OFF ". Switch OFF PAGE: 106 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 25: Installation / Removal

    Any change of ownership shall also be declared and registered with the local registration authority The KANNAD 406 SURVIVAL is fully compatible with the four programming protocols defined by the COSPAS-SARSAT C/S G005 document: • Serialised Number.
  • Page 26 If the pin programming option is selected by the operator, the following equipment are required: • a "Programming Dongle" on each aircraft; • a "Maintenance Dongle" on each ELT spare. Figure 201: Maintenance Dongle PAGE: 202 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 27: Installation

    91.207) The ELT shall not be installed within 60 cm (2 ft) of a magnetic field sensor. KANNAD 406 SURVIVAL can be either packed in a carry off bag or installed on a mounting bracket. A. Installation with Carry-Off Bag KANNAD 406 SURVIVAL is packed in a carry off bag with 3 handles for easy handling.
  • Page 28: Installation With Mounting Bracket

    The hook and loop fastener strap is fitted with two snaps to secure the fastening of the strap. Figure 204: Mounting Bracket, AS-PLUS, P/N S1820511-05 PAGE: 204 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 29: Bracket Installation

    • Disconnect the Programming Dongle (if applicable) and stow it in the compartment designed to this effect inside the bracket. • Reconnect the Water Switch Sensor (if applicable). PAGE: 205 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 30 • Slide the antenna through the hole provided in the floating collar. • Slide the locking pin as shown hereunder. • Install the ELT on the mounting bracket with "lower cover" facing the mounting bracket. PAGE: 206 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 31: Sealing

    The ELT shall be installed with the locking pin so that the switch cannot be set to "ON" (see Installation). • Install a seal using one of the two holes in the cover of the ELT and the mounting bracket. PAGE: 207 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 32: Removal

    • Press the buckles to open the bag top cover. • Turn the ELT sideways to release it from the wedging form. • Deploy the antenna and check that it is connected correctly. PAGE: 208 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 33: Deployment From Mounting Bracket

    • The locking pin will be extracted from the ELT while remaining attached to the mounting bracket. • If, unfortunately, the locking pin was not extracted, slide it to have free access to the switch. PAGE: 209 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 34 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL • Deploy the antenna and check that it is connected correctly. PAGE: 210 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 35: Check

    NOTE: The number of flashes gives an indication of the faulty parameter detected during the self-test. LOW BATTERY VOLTAGE LOW RF POWER FAULTY VCO LOCKING (FAULTY FREQUENCY) NO IDENTIFICATION PROGRAMMED PAGE: 301 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 36 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL PAGE INTENTIONALLY LEFT BLANK PAGE: 302 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 37: Troubleshooting

    Repair and battery replacement can only be carried out by PART 145 / FAR 145 avionics workshops (or equivalent agreement according to local regulations). Additional approval from Orolia is required. Refer to Service Letter SL S18XX50X-25-02 Maintenance Policy for KANNAD ELTs. 2. Faults on Self-test A.
  • Page 38 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL PAGE INTENTIONALLY LEFT BLANK PAGE: 402 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 39: Schematics & Diagrams

    INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL SCHEMATICS & DIAGRAMS 1. Outline Dimensions Note: all dimensions are in millimeters (inches in brackets) PAGE: 501 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 40 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL PAGE: 502 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 41 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL 2. Drilling Mask PAGE: 503 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 42 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL PAGE INTENTIONALLY LEFT BLANK PAGE: 504 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 43: Periodic Inspection

    Some Civil Aviation Authorities may require the ELT be tested periodically. In this case, refer to Service Letter SL S18XX50X-25-12 “Guidelines for periodic inspection” available on the Support section of Orolia website. B. Battery replacement Testing of the various elements of the ELT is mandatory when the battery is replaced: •...
  • Page 44 List of KANNAD Battery Replacement Center is available on our Website: https://www.orolia.com/support/ Orolia S.A.S. Z.I. des Cinq Chemins CS10028 56520 GUIDEL - FRANCE Telephone: +33 (0)2 97 02 49 49 Web: https://www.orolia.com Support: https://www.orolia.com/support/ PAGE: 602 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 45 DISPOSAL 1. End of life statement At the end of KANNAD 406 Survival useful life, the Battery Pack must be removed from the main unit to prevent false alerts. False alerts cause expensive disruption to Search And Rescue services and may endanger lives as a consequence.
  • Page 46 INSTALLATION MANUAL OPERATION MANUAL KANNAD 406 SURVIVAL PAGE INTENTIONALLY LEFT BLANK PAGE: 702 JUN 22/2022 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 47 © 2022 Orolia S.A.S. All rigths are strictly reserved.
  • Page 48 Distributed by Manufactured by Orolia S.A.S Z.I. des Cinq Chemins CS10028 56520 GUIDEL - FRANCE Phone : +33 (0) 2 97 02 49 49 Web: https://www.orolia.com DOC06056G...

This manual is also suitable for:

S1823502-05

Table of Contents