Page 2
Welcome to become a user of Invengo RFID products! We are very glad that you choose the Library Security Pedestal 3A-LR Clear User's Guide. We hope that our equipment can bring convenience to your work.
Page 3
Invengo reserves the right to correct or change the information and instructions in this manual without prior...
Safety Instructions Warning sign Improper operation may do harm to your health. Improper operation may cause damage to the equipment. Caution sign If it is ignored, your operation may not be conducted smoothly. If it is ignored, it may bring you undesirable results.
Catalogue 目录 1. For Your Safety ..................8 1.1 General use ......................8 1.2 Care and maintenance ..................8 1.3 Important safety information ................9 2. Certification ..................... 10 2.1 Occupational health and safety notices ............. 10 2.1.1 Public exposure ....................10 2.1.2 Employees exposure ..................10 2.2 Safety notices ......................
Page 6
4.2 LSP3A RFID system components ..............20 4.3 LSP3A-LR Clear ....................20 4.3.1 Tools required ....................20 4.3.2 Placement of pedestals ................21 4.3.3 Installing the pedestal .................. 23 4.4 LSP3A-LR Clear replacement or extension of an existing installatio 31 5.
Page 7
5.6.3 Adjusting the level of the buzzer sound ..........62 6. Operation ....................63 6.1 Theory of operation ..................63 6.2 Starting the system ................... 63 6.3 Normal operation ....................63 6.4 Shutdown ......................63 7. Maintenance .................... 64 7.1 Servicing the pedestals ..................64 7.2 Electronic and power supply location............
For Your Safety 1. For Your Safety Library Security Pedestal 3A-LR Clear User's Guide 1.1 General use The LSP3A product range is designed to be reliable and to provide continuous, trouble-free service. Please observe the following general tips: 1. Take care not to scratch the device. Keep the device clean. When working with the device, use only INVENGO-approved accessories.
6. Do not attempt to open the device. Non-professional handling of the device may damage it and will void the INVENGO warranty. 7. Handle the device with care. Shock and vibration may break internal circuit boards.
Library Security Pedestal 3A-LR Clear User's Guide 2.1 Occupational health and safety notices INVENGO Products have been designed not to exceed the limits given in the Eu- ropean Standard EN 50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications”...
“Information Technology Equipment Safety” For servicing operations it is recommended to deactivate the RFID system. It is the responsibility of the CII (Certified Integrators by INVENGO) to install the LSP3A as described in INVENGO Product Manuals or INVENGO Documentation. Modification of any INVENGO Library System is prohibited without the written consent of INVENGO.Unauthorized modifications may void the conformity of the...
The LSP3A complies (CE Declaration of Conformity granted) with the European EMC directive. It is the responsibility of the INVENGO Reseller to install the LSP3A as described in this Reference guide or INVENGO Documentation. Any modification of the LSP3A is prohibited without the written consent of IN- VENGO.
Page 13
47 CFR Section 15.21 CAUTION: This equipment may not be modified, altered, or changed in any way without signed written permission from INVENGO. Unauthorized modification may void the equipment authorization from the FCC and will void the INVENGO warranty. ANTENNA REQUIREMENT 47 CFR Section 15.203...
2.4 RoHS and WEEE Directives 2.4.1 RoHS INVENGO certifies that this product is compliant with the European 2011/65/EU & EU 2015/863 for the restriction in Electric and Electronic Equipments (RoHS) of the use of the following hazardous substances: a) Lead...
Library Security Pedestal 3A-LR Clear User's Guide 3.1 Key features As a standalone solution, INVENGO security pedestals do not need to be linked to the library database and can still operate when the Integrated Library System (ILS) is down or under maintenance. The security pedestal does not require addi- tional equipment to operate.
Page 17
All components of the LSP3A system are contained within the LSP3A. At least two pedestals are required for each EAS gate or passageway. A set of pedestals is known as a gate and may consist of several pedestals. Please see section 4 “In- stallation”...
Installation 4. Installation Library Security Pedestal 3A-LR Clear User's Guide 4.1 Recommendations before installation This section describes how to install the LSP3A-LR Clear. 4.1.1 Wire feed sheaths Within the framework installation you need at least a power supply cable sheath and anEthernet cable sheath to connect to the Ethernet network.
4.1.2 Electrical safety rules The LSP3A-LR Clear is powered up via a Mains Supply IEC Cord. A group of up to 5 Pedestals can be daisy chained and powered via a single IEC power cord connected to a wall socket. The mains wall socket should provide at least 2 Ampere and be protected by a differential circuit breaker limiting the cur- rent to 5 Ampere maximum.
4.1.3 Network cable installation The LSP3A delivery package does not include an Ethernet cable to connect to a Local Area Network for remote operation. We recommend the use of a Shielded Ethernet cable, UTP-Cat 5. 4.2 LSP3A RFID system components The components included in the LSP3A RFID System package are listed in Table 4.1 Tble 4.1: LSP3A System Components Quantity...
4.3.2 Placement of pedestals Pedestals must be mounted between 800mm and 1600 mm apart (edge to edge) for maximum reliable performance. There should be at least one pair of pedes- tals at each entrance/exit point of the library. There should be a pedestal at each edge of the entrance, and a Clear space of at least 500 mm around the edge of the pedestals to ensure that the antennas will not be detuned.
Page 22
Indicates the distance (6 ft. 6in.) to a permanent librarian position. Indicates the distance (8 ft.) from other RFID stations. Indicates the recommended distance (36 in. face panel to face panel) between pedestals. Indicates the minimum distance (31½ in.) between a pedestal and large metal object.
4.3.3 Installing the pedestal Once the LSP3A will be powered, the photoelectric sensors will emit a red light beam. To precisely align the sensors and the reflector, an orange LED is present on the back of the photoelectric sensor. When the orange LED is continuously on, the sensor and the reflector are perfectly aligned.
Page 24
● For correct In & Out counter operation, the pedestals must be placed ac- cording to the library flow of patrons. See Figure 4.5 and Figure 4.6 for In & Out counting direction. Figure 4.3: Light Barrier Orange and Green LED Lit when positioning correct (previous model) Before final Installation, do make sure that the Entrance flow is in line with the in Counter Increment Direction Described in Figure 4.5 and Figure 4.6.
Page 25
Then the 2 pedestals can be secured to the ground. A good positioning will ensure the two red LED beams to be back scattered by the reflector as shown below. See Figure 4.3 for LED positioning. Figure 4.4: Light Barrier Latest assembly with 4 LED 7-segment Displays (latest model) Figure 4.5: Top view of correct LSP3A installation and In/Out Counter Directions...
Page 26
Figure 4.6: People Counter View when facing light barrier and counter display Latest People Counters are based on 4-Digit LED Display, Larger and bright- er than previous LCD to ease readout. See Figure 4.7: Latest Light beam Crossing Detection Cells & 4 Digits LED Display detailed description and Figure 4.4: Light Barrier Latest assembly with 4 LED 7-segment Displays photograph.
Page 27
Table 4.2: Description of Buzzer & Counter board Components Reference n° Designation Function Buzzer Volume Adjustment Buzzer Photoelectric Reflex Switch Red Beam Photoelectric Reflex Switch Red Beam LCD or LED Display & Counter Counter Reset Push Button Hexagonal Screw for Light Beam Vertical Alignment Hexagonal Screw for Light Beam Horizontal Alignment On Figure 4.8 below, the two Beam Crossing Cells support is shown.
Page 28
Figure 4.9: Side view of correct LSP3A installation After having defined the location of the pedestals, refer to the mechanical draw- ing of the pedestalmounting diagram for the LSP3A-LR Clear (Figure 4.10). The pedestal is fastened to the floor using screws that are strong enough to support the weight of an average adult falling against The pedestal.
Page 29
1. Identify and mark the location of the holes to be drilled for mounting the ped- estal to the ground. The use of a tape measure and a square is recommended. 2. Drill the cable access and mounting holes according to the type of ground sur- face: a.
Page 30
3. Remove the pedestal from the box. 4. Remove the plastic cover from the both sides after removing the 4 fixing screws. 5. Engage the power supply cable in the electric sheath and the Ethernet cable in the other sheath (please refer to section 4.1.1 “Wire Feed Sheaths”). 6.
8. Once all the LSP3A pedestal have been installed, close the micro circuit-break- er (Figure 4.1) to power up the system before starting configuration operations. Please see section 5 “Configuration”. 9. After the configuration has been carried on, replace the two plastic covers and tighten the 4 fixing screws.
Configuration 5. Configuration Library Security Pedestal 3A-LR Clear User's Guide All configuration operations of LSP3A systems are carried on with the LSP3A Web 5.1 Chip configuration For optimal performance the scanning duration (T_scan) should not exceed 250ms. T_scan is the period to scan all pedestals of a group of N pedestals, i.e. a Master and (N-1) Slave Pedestals.
Example 2: with a system using the ICODE SLI-AFI1-AFI2 in ETSI mode. The scanning duration per pedestal will be: T_single _scan = (10ms+20ms+20ms) = 50ms Example 3: with a system using the ICODE SLI-EAS in ETSI mode. The scanning duration per pedestal will be: T_single _scan = (10ms+20ms+15ms) = 45ms 5.1.2 Global scanning duration The global scanning duration (T_scan) will depend on the synchronization mode...
5.1.3 EAS mode versus AFI mode EAS mode is only supported by the ICODE SLI. AFI mode is supported by most ISO15693 chips, from major chip manufacturers (NXP, Texas Instrument, STM, In- fineon, MeMarin…). EAS digital burst is a prime number data stream of 128 bits which is read out af- ter sending a check EAS command to the Tag.
Page 35
Figure 5.1: Chronogram Sample (1 Master/ 4 Slaves) ● Synchronization burst: start burst to synchronize the gates (Period of T Scan ● Processing time (Pt): depends on the number of tags to be detected and the settings. The fastest is when only detection is used (EAS burst or AFI), the slowest when all features are used (AFI + Read AFI + Read 16 blocks of memory).
This process is repeated indefinitely. In case the master does not receive back the synchronization burst from the last slave after a defined period, it will automatically restart the synchronization pro- cess. The number of pedestals is not limited to any particular number as long as each gate is close enough to its neighboring pedestal and that the overall scanning time does not exceed a few 100ms to allow for a safe detection at 1m/s pace trough any gate.
Page 37
Wire Figure 5.2: 3 Pedestals Configuration Example and Token Propagation Synchronization Token hand over Wire connection: First prepare a cable of appropriate length to connect 2 consecutive Electronics as shown in Figure 5.3 and Figure 5.4 A minimum wire gauge of 22AWG (0.2mm²) is enough, preferably a twisted pair. Screw at each extremity of the cable a 2-way connector with ground wire at the same position for each module.
Page 38
Figure 5.3: Detailed Wire Synchronization Assembly Then unscrew the 4 screws to open the bottom plastic cover panel of each ped- estal forming the aisle to gain access to the Product Electronic Module and con- nect the top 2-way connector as shown in Figure 5.4 thereafter. Figure 5.4: LSP3A-LR Clear PEM Connectors &...
Page 39
Steps to undergo: 1. Prepare a 2 wire cable of appropriate length and number of connectors to wire up each pedestal. Use the 3.81 mm Push-On Green Plugs Vertical Cable Entry provided. 2. Connect all pedestals Synchronization to the Synchronization I/O as shown on Figure 5.4.
5.3 Parameters configuration of the ethernet interface Don’t forget to power up your installation before carrying on the following steps. The first step is to allocate a unique IP address to each LSP3A. This operation will allow identifying each LSP3A on site before configuring them on the Ethernet network.
Need help?
Do you have a question about the 3A-LR Clear and is the answer not in the manual?
Questions and answers