Hci server – amd epyc 9004 dp 2u 4-node server 8 x gen4 nvme/sata 2600w (aan1) and hci server – amd epyc 9004 dp 2u 4-node server 8 x gen4 nvme/sata 3000w (aaw1) (166 pages)
Hci server – amd epyc 9004 dp 2u 4-node server 8 x gen4 nvme/sata 2600w (aan1) and hci server – amd epyc 9004 dp 2u 4-node server 24 x gen4 nvme/sata 3000w (aaw1) (166 pages)
Amd epyctm 7002 series processor server (139 pages)
Summary of Contents for Gigabyte H274-S61-LAW1
Page 1
H274-S61-LAW1 High Density Server - Intel® Xeon® 6 Processors 2U 4-Node DP 8-Bay Gen5 NVMe/SATA/SAS-4 DLC User Manual Rev. 1.0...
Page 2
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal: http://reseller.b2b.gigabyte.com For further technical assistance, please contact your GIGABYTE representative or visit https://esupport.gigabyte.com/ to create a new support ticket For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email: server.grp@gigabyte.com...
Page 3
Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
Page 6
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the user manual and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. Security Server Socket Operating Properties System 2U 4-Node - Rear access Dimension 440 (W) x 87.5 (H) x 877 (D) mm System fan Power Supply Superchip...
Page 12
Storage Front hot-swap: 8 x 2.5" Gen5 NVMe/SATA/SAS-4 (NVMe & SATA from CPU_1) Socket Security Server Operating Properties Optional internal M.2 (CMTP160 x 4): 4 x M.2 (2260/2280/22110), PCIe Gen4 x4, from CPU_1 Superchip System fan Power Supply [1] SAS card is required to support SAS drives.
Page 13
Max 3000W/ 208-240V~ or 240Vdc Input +12.2V/ 245.9A +12.2Vsb/ 3A [1] The system power supply requires C19 power cord. System Aspeed® AST2620 Chassis Management Controller Management GIGABYTE Management Console web interface Dashboard Security Server Operating Properties HTML5 KVM ...
Page 14
Security Server Operating Properties Operating Operating temperature: 10°C to 35°C Operating humidity: 8-80% (non-condensing) Properties Superchip System fan Power Supply Non-operating temperature: -40°C to 60°C Non-operating humidity: 20%-95% (non-condensing) Note: The ambient temperature and relative humidity of the environment depend on ...
System Block Diagram 8-Channel DDR5, 8 x DIMMs 8-Channel DDR5, 8 x DIMMs RDIMM: Up to 6400 MT/s RDIMM: Up to 6400 MT/s CPU0 CPU1 MCR DIMM: Up to 8000 MT/s MCR DIMM: Up to 8000 MT/s 4 x UPI Intel Xeon 6 processors Intel Xeon 6 processors (LGA4710 Socket)
Multiplexing Management Topology Multiplexing Management Example Spanning Tree Protocol (STP) must be enabled in LAN switch function if using ring topology. Hardware Installation - 17 -...
Page 18
LAN Switch and Compute Node Connection Example Correct Incorrect Hardware Installation - 18 -...
Chapter 2 System Appearance Front View NODE1 NODE2 NODE3 NODE4 Description Front Panel LEDs and buttons • Please Go to Chapter 2-3 Front Panel LED and Buttons for detail description of function LEDs. System Appearance - 19 -...
Rear View PSU2 SLOT2 PSU1 SLOT1 Description PCIe Slot Node System Status LED Mini DisplayPort 2 x USB 3.2 Gen1 GbE LAN Port x 2 BMC Server Management LAN Port OCP 3.0 Slot (SFF Type) PCIe Slot Coolant Pipe Slot System Appearance - 20 -...
Front Panel LED and Buttons NODE1 NODE3 NODE2 NODE4 No. Name Color Status Description This LED represents the RoT function LED behavior. System Status Please see the following section for detail LED behavior. (Note) Reset Button Press this button to reset the system. Green System is powered on Green...
RoT LEDs NODE3 NODE1 Status LED Status LED ID LED ID LED NODE4 NODE2 Status LED Status LED ID LED ID LED LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images...
Page 23
Blinks Blue Blinks Green 2 times per second 2 times per second BMC : AUTH fail after doing recovery (Note3) [ON OFF OFF] [ON OFF OFF] Blinks Blue Blinks Amber 2 times per second 2 times per second BIOS : AUTH fail after doing recovery (Note3) [ON OFF OFF] [ON OFF OFF]...
Rear System LAN LEDs Name Color Status Description Yellow 1Gbps data rate 1GbE Green 100 Mbps data rate Speed LED 10 Mbps data rate Link between system and 1GbE Green network or no access Link/ Blink Data transmission or receiving is occurring Activity LED No data transmission or receiving is occurring System Appearance...
Power Supply Unit LED PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updateing mode AC cord unplugged or AC power lost; with a second power supply in parallel still with AC input power Amber Power supply critical event causing shut down:...
Hard Disk Drive LEDs HDD Present RAID SKU Rebuilding LED1 Locate HDD Fault Access (No Access) Disk LED Green ON(*1) BLINK (*2) (LED on Back Panel) Amber No RAID configuration Green ON(*1) (via HBA) Removed HDD Slot (LED on Back Panel) Amber Green BLINK (*2)
Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged electrostatic discharge. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
Installing the Hard Disk Drive Read the following guidelines before you begin to install the Hard disk drive: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if inserted incorrectly. •...
Removing the Node Read the following guidelines before you begin to replace a node: • To make sure the system operates normally, please power off only the node that will be replaced or reconfigured. Follow these instructions to remove a node: Press the release latch while simultaneously pushing down the tray handle for the node.
How to Get the BMC Password Follow these instructions to get the BMC Password: Pull out the tab and then you can find the password information on the tab. System Hardware Installation - 30 -...
Removing Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the system cover: Loosen and remove the six screws securing the back cover. Slide the cover to the rear of the system and remove the cover in the direction of the arrow.
Liquid Cooling Assembly Information The liquid cooling assembly is designed to capture heat from the processors in the node and cool the components. The coolant flow for the assembly is produced by the eight quick disconnects at the rear of the server chassis.
3-5-1 Liquid Cooling Specifications The cold plate assembly in the liquid cooling assembly mounts directly on top of the processors. The retention mechanism for installation on top of the processors is integrated into the cold plate. The liquid coolant contained within the tubes, is a mixture of demineralized water and propylene glycol with the following beneficial features: Anti-Freeze, Anti-Corrosion and Anti Bacterial.
Removing and Installing the Fan Duct Follow these instructions to remove/install the fan duct: Remove the four screws securing the fan ducts. Lift up to remove the fan ducts To install the fan duct, align the fan duct with the guiding groove. Push down the fan duct into chassis until its firmly seats, then install the four screws to secure the fan ducts in place.
Installing the CPU and the Coolant Pipe Module Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
Page 36
Carrier Types used for Package Types Granite Rapids-SP HCC Granite Rapids-SP LCC Package Type Granite Rapids-SP XCC Sierra Forest-SP Clearwater Forest-SP Carrier Code Shim? Integrated TIM Break Lever NOTE! • The carrier code is marked on each carrier and matches a code laser marked on to the IHS(Integrated Heat Spreader) to ensure the right parts are used together.
Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
3-8-2 Installing the Memory Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR5 DIMMs on this motherboard. Follow these instructions to install the Memory: Insert the DIMM memory module vertically into the DIMM slot, and push it down.
3-8-3 DIMM Population Table ntel Xeon 6700E-Series Memory Support Channel Speed (MT/s); Voltage (V); DIMM Capacity (GB) Slots per Channel (SPC) & DIMMs per Ranks Per DIMM and Channel (DPC) Type DRAM Density Data Width 16Gb 32Gb 1DPC/2SPC 2DPC/2SPC 1DPC 2DPC 1DPC 1.1V...
Page 40
Intel Xeon 6500P/6700P-Series Memory Support Channel Speed (MT/s); Voltage (V); DIMM Capacity (GB) Slots per Channel (SPC) & DIMMs per Ranks Per Channel Density (DPC) Type DIMM and DRAM Density Data Width 16Gb 24Gb 32Gb 1DPC/2SPC 2DPC/2SPC 1DPC 2DPC 1DPC 2DPC 2DPC 1.1V...
3-8-4 Processor and Memory Module Matrix Table CPU0 CPU1 Memory Q’ty for each CPU 1 DIMM 4 DIMM 8 DIMM 12 DIMM 16 DIMM NOTE: • Xeon 6700E/6500E-series do not support 12 DIMMs Configuration. System Hardware Installation - 41 -...
Installing the PCI Expansion Card • The PCI riser assembly does not include a riser card or any cabling as standard. To install a PCI card, a riser card must be installed. Follow these instructions to install the left PCI bracket riser: Remove the three screws securing the riser bracket to the system.
Page 43
Follow these instructions to install the right PCI Expansion card: Remove the three screws on the riser bracket to the system. Lift up the riser bracket out of system. Remove the screw securing the side bracket to the riser bracket. Remove the side bracket Align the PCIe card to the riser guide slot and push in the direction of the arrow until the PCI-E card sits in the PCI card connector.
3-10 Removing and Installing the Rear IO Card Follow these instructions to install the Rear IO card: Remove the three screws securing the Rear IO card to the system. Lift up the Rear IO card out of system. Reverse steps 1 - 2 to install the Rear IO card back into the system. System Hardware Installation - 44 -...
3-11 Installing the Mezzanine Card 3-11-1 Installing the OCP 3.0 Mezzanine Card Use of the following type of OCP 3.0 NIC is recommended: • OCP 3.0 SFF with pull tab • OCP 3.0 SFF with ejector latch Follow these instructions to install an OCP 3.0 Mezzanine card: Remove the one screw securing the OCP 3.0 card slot cover.
3-12 Replacing the Fan Assembly • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to replacing a system fan.
3-13 Replacing the Power Supply Follow these instructions to replace the power supply: Pull up the power supply handle and press the retaining clip on the right side of the power supply along the direction of the arrow. At the same time, pull out the power supply by using its handle. Insert the replacement power supply firmly into the chassis.
Jumper Setting Default Enable Clear CMOS 1 2 3 CLR_CMOS CPU0 CPU1 S3_MASK Stop initial power on when BMC is not ready Normal [Default] BIOS_RCVR BIOS recovery mode Normal [Default] BIOS_PWD Clear supervisor password Normal [Default] RST BMC_EN ID button to enable BMC reset Normal [Default] NCSI Switch SW.1...
Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
Page 57
Main This setup page includes all the items of the standard compatible BIOS. Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
Page 59
Parameter Description Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information BMC Firmware Version Displays BMC firmware version information.
Page 60
Parameter Description System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. BIOS Setup - 60 -...
Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 61 -...
5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be TPM v1.2 Support available. Options available: Disable, Enable. Default setting is Enable. BIOS Setup - 62 -...
5-2-2 Serial Port Console Redirection Parameter Description Console redirection enables the users to manage the system from a COM1 Console remote location. Redirection (Note) Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items. Please note that this item is configurable when COM1 Console Redirection is set to Enabled.
Page 64
Parameter Description Parity – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
Page 65
Parameter Description Serial Port for Out-of-Band Management / Windows EMS console redirection allows the user to configure Console Redirection Emergency Management Settings to support Out-of-Band Serial Port management. Services (EMS) Console Options available: Enabled, Disabled. Default setting is Disabled. Redirection (Note) Press [Enter] to configure advanced items.
5-2-3 SIO Configuration Description Parameter Displays the AMI SIO driver version information. AMI SIO Driver Version Super IO Chip Logical Device(s) Configuration Press [Enter] to configure advanced items. Use This Device – When set to Enabled allows you to configure the serial port settings. When set to Disabled, displays no configuration for the serial port.
5-2-4 PCI Subsystem Settings Parameter Description PCI Bus Driver Version Displays the PCI Bus Driver version information. When enabled, this setting will initialize the device expansion SLOT_# I/O ROM (Note1) ROM for the related PCI-E slot. Options available: Enabled, Disabled. Default setting is Enabled. SLOT_# Lanes Change the PCIe lanes.
Page 68
Parameter Description PCI Devices Common Settings If system has Resizable BAR capable PCIe Devices, this option Enables or Disables Resizable BAR Support. Re-Size BAR Support Options available: Enabled, Disabled. Default setting is Disabled. If the system has SR-IOV capable PCIe devices, this item SR-IOV Support Enable/Disable Single Root IO Virtualization Support.
5-2-5 USB Configuration Parameter Description USB Configuration USB Devices: Displays the USB devices connected to the system. Enable/Disable the XHCI (USB 3.0) Hand-off support. XHCI Hand-off Options available: Enabled, Disabled. Default setting is Enabled. USB Mass Storage Driver Enable/Disable the USB Mass Storage Driver Support. Support Options available: Enabled, Disabled.
5-2-7 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 71 -...
5-2-8 KMIP Server Configuration Parameter Description KMIP Server IP address KMIP TCP Port Number Enter the correct timem zone for this server. Time Zone Default setting is GMT+8. Use User and password credentials to authenticate the Client. Client Credentials Options available: Enabled, Disabled, Clear. Default setting is Enabled.
5-2-10 Chipset Configuration Parameter Description Defines the power state to resume to after a system shutdown that is due to an interruption in AC power. When set to Last State, the system will return to the active power state prior to shutdown. When set to Restore on AC Power Loss (Note) Power Off, the system remains off after power shutdown.
5-2-11 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
5-2-12 iSCSI Configuration Parameter Description Press [Enter] to configure advanced items. iSCSI Initiator Name – Only IQN format is accepted. Range: from 4 to 223 Host iSCSI Configuration Add an Attempt Delete Attempts Change Attempt Order BIOS Setup - 76 -...
Page 78
Description Parameter Press [Enter] to configure advanced items. Link Speed – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration ...
5-2-14 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN VLAN ID – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
5-2-15 MAC IPv6 Network Configuration Parameter Description Press [Enter] to configure advanced items. Displays the MAC Address information. Interface ID – The 64 bit alternative interface ID for the device. The string is colon separated. e.g. ff:dd:88:66:cc:1:2:3. DAD Transmit Count ...
5-2-16 MAC IPv4 Network Configuration Parameter Description Indicates whether network address is configured successfully or not. Configured Options available: Enabled, Disabled. Default setting is Disabled. Options available: Enabled, Disabled. Default setting is Disabled. Enable DHCP Local IP Address Press [Enter] to configure local IP address. Press [Enter] to configure local NetMask.
Chipset Menu The Chipset Setup menu displays submenu options for configuring the chipset functions. Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 83 -...
Page 85
Description Parameter Processor Configuration Press [Enter] to configure advanced items. CPU Socket 0/1 Configuration – Core Disable Bitmap(Hex) • Number of Cores to enable. 0 means all cores. FFFFFFF Pre-Socket Configuration means to disable all cores. The maximum value depends on the number of CPUs available.
5-3-2 Common RefCode Configuration Parameter Description Common RefCode Configuration Divide physical NUMA nodes into evenly sized virtual NUMA nodes in ACPI table. This may improve Windows performance on CPUs Virtual Numa (note) with more than 64 logical processors. Options available: Enable, Disable. Default setting is Disable. The numbber of virtual NUMA nodes per physical NUMA nodes.
Page 89
Description Parameter Press [Enter] to configure advanced items. Uncore Status – Press [Enter] to view the Uncore status. Link Frequency Select – Selects the UPI link frequency. – Options available: 12.8GT/s, 14.4GT/s, 16.0GT/s, Auto, Use Per Link Setting. Default setting is Auto. ...
5-3-4 Memory Configuration Description Parameter Integrated Memory Controller (iMC) When set to Enable, the system enforces Plan Of Record restrictions for DDR frequency programming. Enforce DDR Memory Frequency POR Options available: POR, Disable. Default setting is POR. Maximum Host DDR Memory Frequency Selecttions in MT/s. If the AUTO option has been selected, a frequency is chosen automatically based on the minimum tCK given by the SPD.
Page 91
Description Parameter Press [Enter] to view memory topology with DIMM population Memory Topology information. Press [Enter] to configure advanced items. Intel(R) Flat Memory Mode Support. – Options available: Enabled, Disabled. Default setting is Disabled. Memory Map DDR CXL Heterogeneous Interleave support. ...
Page 92
Description Parameter ADDDC Sparing (Note) – Enable/Disable ADDDC Sparing. – Options available: Disabled, Enabled. Default setting is Disabled. Enable ADDDC Error Injection – Options available: Disabled, Enabled. Default setting is Enabled. Patrol Scrub Memory RAS Configuration – Options available: Disabled, Enable at End of POST. Default (continued) setting is Enable at End of POST.
5-3-6 Advanced Power Management Configuration Description Parameter Press [Enter] to configure advanced items. Intel SST-PP – Intel SST-PP Select allows user to choose level. – Options available: Auto, Level 0, Level 1. Default setting is Auto. SpeedStep (Pstates) –...
Page 95
Description Parameter Press [Enter] to configure advanced items. Hardware P-States – When this item is disabled, the processor hardware chooses a P-state based on OS Request (Legacy P-States). – In Native mode, the processor hardware chooses a P-state based Hardware PM State Control on OS guidance.
5-3-9 Power Policy Description Parameter Selects a Power Policy Quick Setting. Options available: Standard, Best Performance, Energy Efficient. Default Power Policy Quick Settings setting is Standard. Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor SpeedStep (Pstates) load.
Page 100
Description Parameter Options available: Enable, Disable. Default setting is Enable. Hardware Prefetcher Options available: Enable, Disable. Default setting is Enable. Adjacent Cache Prefetch Options available: Enable, Disable. Default setting is Enable. DCU Streamer Prefetcher Options available: Enable, Disable. Default setting is Enable. L1 Next page Prefetcher Options available: Disable, Native mode, Out of Band mode, Native Mode Hardware P-States...
Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Options available: Enabled, Disabled. Default setting is Enabled. FRB-2 Timer (Note1) Configures the FRB2 Timer timeout. The value is between 1 to 30 minutes. timeout Default setting is 6 minutes. Configures the FRB2 Timer policy.
Page 102
Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC VLAN Press [Enter] to configure advanced items. Configuration BMC network Press [Enter] to configure advanced items. Configuration IPv6 BMC Network Press [Enter] to configure advanced items.
5-4-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled, Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Options available: No, Erase SEL Yes, On next reset,...
5-4-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 104 -...
5-4-3 BMC VLAN Configuration Description Parameter BMC VLAN Configuration Select to configure BMC VLAN ID. The valid range is from 0 to 4094. When BMC VLAN ID set to 0, BMC VLAN ID will be disabled. Select to configure BMC VLAN Priority. The valid range is from 0 to 7. BMC VLAN Priority When BMC VLAN ID is set to 0, BMC VLAN Priority will not be selected.
5-4-5 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
5-5-1 Secure Boot The Secure Boot feature is applicable if supported by your Operating System. If your Operating System is not supporting Secure Boot, the system will hang when starting the Operating System. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function.
Page 110
Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
Page 111
Parameter Description Authorized TimeStamps (DBT) – Displays the current status of the Authorized TimeStamps Database. – Press [Enter] to configure a new DBT or load additional DBT from storage devices. Key Management – Options available: Update, Append. (continued) OsRecovery Signatures ...
Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. BIOS Setup - 112 -...
Page 113
Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting. Press the numeric keys to input the desired values. Enable/Disable the Bootup NumLock function. Bootup NumLock State Options available: On, Off. Default setting is On. Enable/Disable showing the logo during POST.
Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save and Exit Options available: Yes, No.
Page 115
Parameter Description Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components Restore Defaults and you choose to load these settings, the system might not function properly.
BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.
BIOS POST Beep code (AMI standard) 5-9-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...