Recommended Installation, Maintenance,
and Inspection Instructions
for GILBARCO CATLOW Breakaways
Use only Catlow-supplied O-rings for all maintenance and repairs
ENSURE TO CHECK THE FOLLOWING DAILY
- Check breakaways for leaks
- Whip hose is in good condition, no cuts, cracks, or blisters
- Whip hose fittings are clean and dry
CAUTION
GILBARCO CATLOW ASSUMES NO LIABILITY FOR ANY BREAKAWAY REPAIRED IN THE FIELD. GILBARCO CATLOW
MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR USE.
CAUTION
GILBARCO CATLOW products should be used with applicable federal, state, and local laws and regulations. Product selection
should be based on physical specifications and limitations and compatibility with the environment and material to be handled.
LIMITED WARRANTY
GILBARCO CATLOW expressly warrants that its products shall be free from defects in material and workmanship for a period of one
year from the date of manufacture. This warranty is limited to repair or replacement by GILBARCO CATLOW upon return of the
product to the GILBARCO CATLOW factory. This warranty does not apply in the event of any misuse or neglect of the product.The
foregoing warranty is the exclusive remedy of purchasers of GILBARCO CATLOW products. GILBARCO CATLOW expressly
disclaims any warranties, other than the foregoing express warranty, including the implied warranties of merchantability and fitness
for a particular purpose, and disclaims any and all liability for consequential damages resulting from the use of its products.
All product names, logos, and brands are the property of their respective owners and are for identification purposes only. Use of
these names, logos, and brands does not imply endorsement.
7300 West Friendly Avenue
Greensboro, NC 27410
(CAT- 42) R0914
GILBARCO CATLOW
www.catlow.com
Phone: (800) 222-8569 Fax: (855) 324 3998
Page 4
Recommended Installation, Maintenance,
and Inspection Instructions
for GILBARCO CATLOW Breakaways
WARNING
• USE ONLY ON SYSTEMS RATED AT 50 PSI MAXIMUM.
• USE ON SYSTEMS HAVING HIGHER STATIC PRESSURE (MAY CAUSE PREMATURE SEPARATION).
• ALWAYS TEST ELECTRICAL CONTINUITY BY FOLLOWING PETROLEUM EQUIPMENT INSTITUTE
(PEI)-RECOMMENDED TEST PROCEDURE (PEI/RP400-02).
BEFORE YOU BEGIN
• Refer to the breakaway model for the maximum value of pull force before you proceed with the installation instructions.
• Ensure care when testing to prevent damage to the dispenser or physical injury.
• Only qualified personnel should inspect/repair the equipment (PEI/RP500 11 9.2.3).
• ALL DISPENSERS MUST BE BOLTED TO THE ISLAND (NFPA
PEI/RP500-11 2.2).
CONFIRM DISPENSER IS SECURE
• Attach a spring scale to the dispenser where the breakaway will be installed.
• Apply a 350 lbs pull force at various angles and check the emergency valves,
dispenser, and hose assembly [Underwriters Laboratories (UL
• Release the load and complete the installation of the breakaway.
INSTALLATION NOTES
Notes: 1) The GILBARCO CATLOW in-line breakaway must always be installed between two hose sections (for example, whip
and main hose).
2) On side hose connections, install the breakaway between the nozzle and the hose retractor (NFPA 30A 6.5.3). DO NOT
INSTALL THE BREAKAWAY ON THE DISPENSER SIDE OF THE HOSE RETRACTOR.
3) On an overhead hose connection, install the short section of whip hose, followed by the breakaway, hose, and nozzle.
4) ISBA Models are installed between the nozzle and the primary hose.
INSTALLATION INSTRUCTIONS FOR IN-LINE and ISBA BREAKAWAYS
To install in-line breakaways, proceed as follows:
1. Isolate/turn OFF the dispenser and relieve the line pressure from the system by opening the nozzle and allowing the system to
drain into an approved metal container.
2. Observe the flow direction arrow on the breakaway and install with the flow arrows pointing towards the nozzle.
3. Use thread sealant recommended by UL for petroleum products on pipe thread connections, such as Gasoila E-Seal formulated
for E10 and E85.
4. Use oil or grease on straight or metric thread O-ring fittings, such as Waypure 68 Oil, Petroleum Jelly, E-Seal, Parker Super
O-Lube. DO NOT USE TEFLON
TAPE.
®
5. Tighten hoses using the hex on the breakaway that is adjacent to the hose being installed (see examples 1 and 2).
Tighten parts using adjacent hex features only
Hose
ISBA
ISBA Breakaway Models
CAUTION
Applying torque simultaneously to both ends of the breakaway may cause the breakaway to separate or
damage the anti-rotation pins.
6. Activate/turn the dispenser ON and purge the hoses and nozzles of air into an approved metal container.
7. Check the system for leaks and replace any item that exhibits signs of leakage.
Notes: 1) Use only UL-listed paste type thread sealant, such as Gasoila E-Seal formulated for E10 and E85.
2) Hoses should not be long enough that a vehicle could drive over the hose resulting in a direct pull on the retractor cable
or dispenser and bypass the breakaway.
ALWAYS REFER TO YOUR LOCAL CITY, STATE,
OR FEDERAL TESTING REGULATIONS
7300 West Friendly Avenue
Greensboro, NC 27410
MDE-5335C
(CAT- 42) R0914
May 2022
30A 6.3.4 and
®
STANDARD 567)].
®
Nozzle
Hose
Breakaway
In-Line Breakaway Models
ONLY QUALIFIED PERSONNEL SHOULD
INSPECT/REPAIR EQUIPMENT (PEI/RP50 11 9.2.3)
GILBARCO CATLOW
www.catlow.com
Phone: (800) 222-8569 Fax: (855) 324 3998
Page 1